• Title/Summary/Keyword: Fire- and explosion safety

Search Result 405, Processing Time 0.023 seconds

Combustion Characteristics of Immobilized Alcohols in Porous Material (다공성 물질에 함침시킨 알콜의 연소특성)

  • 우인성;황명환
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.76-82
    • /
    • 1994
  • Combustion phenomena(characteristics) of organic solvents including various alcohols Immobilized on ceramic balls were studied. Experiments were performed by burning methyl, ethyl, and propyl alcohol immobilized on sands (particle size 0.35mm) and coramic balls(particle size 1~5mm) to measure mass burning rate, height burning rate and combustion temperature. The longer time from ignition to extinguishment was resualted from the larger particle size of ceramic balls and the smaller size of ceramic balls exhibited the higher mass burning rate. Of alcohols tested the relative magnitude of facilitation of combustion was methyl >ethyl >propyl. Combustion temperatare of alcohols, without regard to the types of alcohols, was not increased with smaller ceramic balls(up to 3mm of particle size). However, with larger ceramic balls, combustion temperatare of alcohols was increased by 40~5$0^{\circ}C$ and the highest combustion temperatare was obtained with sands(particle size 0.35mm). Also, second rising was occurred at the combustion time of I5-20min. and this second rising time was increased with the smaller particle. These results will be able to be used for petrochemical industries using particles to evaluate the danger of fire and explosion.

  • PDF

High Voltage Wiring System Evaluation Methode of FCEV (Fuel Cell Electric Vehicle) (수소연료전지 자동차용 고전압 배선 시스템 평가 기술 개발)

  • Lim, Ji-Seon;Lee, Jeong-Hun;Lee, Hyo-Jeong;Na, Joo-Ran
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.330-336
    • /
    • 2012
  • FCEV uses 250 ~ 450 V instead of using 12 V battery. High voltage vehicle can cause electric shock, fire and explosion accident. Therefore, it has potential factors that can cause hazard of safety for users. United states of America and Europe legislate regulations such as ECE R100, FMVSS 305 for regulating electrical safety during driving or after collision. The company manufacturing high voltage components must do advanced R&D about Method for improving and confirming the safety of high voltage. We develop the specific hardware components of high voltage wiring system for the power train system and power supply system of Hyundai Motors FCEV. This paper shows test method of insulative performance for securing the electrical safety of high voltage components such as power cable, connectors and buss-bar, and proposals the guide line value for human safety of FCEV according to the test result of our development components.

Development of Accident Taxonomy for Experimental Laboratory (연구실 사고분류 체계 개발)

  • Park, Kyoshik
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.49-53
    • /
    • 2016
  • The goal of this study is to analyze accidents occurred at experimental laboratory and to suggest hierarchical taxonomy applicable to prepare countermeasures reducing the experimental laboratory accidents. Recent 5 years accidents were analyzed and classified according to their primary cause, facility or human. Then in case of facility, the accidents were further classified whether they can be fixed by organization or by individual. In case of human factor, they were classified into physical, chemical, or biological to prepare precise measures. Depending on the adequacy of appropriate practice, several measures were suggested such as; whether to improve training of laboratory workers, or to improve training the system, or to improve or prepare practice substantially. A new taxonomy for laboratory accident was suggested complying other governmental agencies' classification such as KOSHA and KGS. Additionally, two kinds of possibilities were suggested such as possibility of major accident and possibility of disaster which can be defined as laboratory accident causing large scale of harmful consequence to residential area or environment by fire, explosion and/or toxic release of hazardous chemicals and/or microbiology.

Development and Evaluation of Human Reliability Analysis Model for the Reduction of Human Errors (인적오류 저감을 위한 인간 신뢰도 분석 체계 및 평가에 관한 연구)

  • Jung, Kyung-Hee;Byun, Seong-Nam;Cho, Jai-Rip
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2048-2051
    • /
    • 2010
  • Almost all companies have paid much attention to the safety management ranging from maintenance to operation even at the stage of designing in order to prevent accidents, but fatal accidents continue to increase throughout the world. In particular, it is essential to systematically prevent such fatal accidents as fire, explosion or leakage of toxic gas at factories in order to not only protect the workers and neighbors but also prevent economic losses and environmental pollution. In addition, HRA may be used to detect the human errors which may cause accidents or trace back to any mistake on the part of workers. Usually, HRA technique is used in association with other risk assessment techniques. Moreover, it can serve to enumerate the human errors which may occur during operation or down-time or correct the existing system to reduce the mistakes. This work focuses on the coincidence of human error and mechanical failure for management of human error, and on some important performance shaping factors to propose a method for improving safety effectively of the process industries.

  • PDF

A Study on the Flash Point Determination of Toluene-o-Xylene and Toluene-Methyl Ethyl Ketone Mixtures by Air-Blowing Method (유통법을 사용한 톨루엔과 o-크실렌 및 톨루엔과 메틸에틸케톤 혼합용제의 인화점 측정에 관한 연구)

  • 신열우;목연수;최일곤
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.2
    • /
    • pp.92-96
    • /
    • 1995
  • The flash point is generally used as a hazardous index of fire or explosion of a flammable liquid. In this study, the lower flash points and the upper flash points according to the composition of Toluene-o-Xylene and Toluene-Methyl Ethyl Ketone mixtures are determined by air-blowing method. As results, relations between the flash points and the compositions of mixtures ; (1) for Toluene-o-Xylene mixtures $T_{fL}$=25.23 $\alpha$ +5.34 $T_{fu}$=27.36 $\alpha$ +40.50 (2) for Toluene-Methyl Ethyl Keton mixtures $T_{fL}$=10.00 $\beta$-5.00 $T_{fu}$=16.91 $\beta$+20.45.

  • PDF

A Comparative Study on the Methods of Consequence Estimation in Fire and Explosion Hazards (화재 및 폭발재해의 강도 산정에 관한 비교 연구)

  • 김구회;백종배;고재욱
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.2
    • /
    • pp.87-93
    • /
    • 1993
  • Many methods to assess hazards caused by the risks increased with the growth of petrochemical industry. The manual of International Atomic Energy Agency which was much more applied to quantitative analysis of the real situation and the CPQRA is introduced to verify the theoretical background of this manual. Than other methods, as a result, we can see that this manual, which is simple to use and requires a little information, shows similar results to those of calculation by numerical formula. Also, the program code of this manual was materialized and if it is possible to obtain adequate parameters to our circumstance, the manual will be quite useful in early risk analysis.

  • PDF

Case Analysis of the Harmful Chemical Substances' Spill (유해화학물질 유출의 사례 분석)

  • You, Jisun;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.90-98
    • /
    • 2014
  • Lately accidents of harmful chemical substance in korea were repeatedly replaying. We studied problems and preparation plan in 2008 years~2014 years through analysis cases of harmful chemical substance. Leakage of chemical substance's accident situation shows that leakage in the workplace is the most 10 cases, accounting for 58.6% is the largest proportion in 2009. Leakage according to explosion accounting for 50% (5 cases) in 2004, 25% (4 cases) in 2007 and 33.3% (4 cases) in 2011 has very irregular change. Therefore, A major cause of accidents is lack of safety management. Harmful chemical substance showed various aspects, high residual substance and non-visible characteristic so response and recovery was easy. And the second damage to move a distance causes environment pollution. So a mutual-assistance system and integrated system of related organization have to build and expert of chemical incident response and therapist of chemical substance response have to establish to do efficient and rapid response.

The study of Taxonomy of Performance Shaping Factors for Human Error Management (인적오류 관리를 위한 수행영향인자 분류에 관한 연구)

  • Jung, Kyung-Hee;Cho, Jai-Rip
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2010.04a
    • /
    • pp.157-160
    • /
    • 2010
  • Almost all companies have paid much attention to the safety management ranging from maintenance to operation even at the stage of designing in order to prevent accidents, but fatal accidents continue to increase throughout the world. In particular, it is essential to systematically prevent such fatal accidents sa fire, explosion or leakage of toxic gas at factories in order to not only protect economic losses and environmental pollution. In addition, HRA may be used to detect the human errors which may cause accidents or trace back to any mistake on the part of workers. This work focuses on the coincidence of human error and mechanical failure for management of human error, and on some important performance shaping factors to propose a method for improving safety effectively of the process industries.

  • PDF

Calculation and Measurement of Flash Point for n-Decane + n-Octanol and Acetic Acid + n-Butanol Using a Tag-Open-Cup Apparatus (Tag 개방식 장치를 활용한 n-Decane + n-Octanol계 및 Acetic Acid + n-Butanol계의 인화점 측정과 계산)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.45-50
    • /
    • 2015
  • The flash point is one of the most important properties for characterizing the fire and explosion hazard of liquid solutions. In this study, a Tag open-cup apparatus was used to measure the flash points of two flammable binary mixtures, n-decane + n-octanol and acetic acid + n-butanol. The flash point temperature was estimated using the UNIFAC (Universal Functional Activity Coefficient) group contribution model and optimization method. The experimentally derived flash point was also compared with the predicted flash point. The two methods can estimate the flash point fairly well for the n-decane + n-octanol and acetic acid + n-butanol systems.

The Measurement and Prediction of Maximum Flash Point Behavior for Binary Solution (이성분계 용액의 최대인화점 현상의 측정과 예측)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.70-74
    • /
    • 2013
  • The flash point is one of the most important physical properties to charaterize fire and explosion hazard of liquid solutions. The maximum flash point of liquid mixture is larger than those of the individual components. In this study, the flash points of 2-pentanol+acetic acid system were measured by Seta flash closed cup tester. This system exhibited the maximum flash point behavior. The flash points were estimated by the Raoult's law and the optimization methods using the van Laar and Wilson equations. The calculated values by optimization methods were found to be better than those based on the Raoult's law.