Resently, Fiber Reinforced Concrete is used for not only preventing crack of concrete but also reinforcing general methods. Steel Fiber and PP(poly-propylene) Fiber are usually used as fiber reinforced materials. However, using these materials for shotcrete on Railway tunnel can cause some problems such as damage of pressure hose and shotcrete rebound. In addition, Steel fiber is an expensive material and it can cause safety problems during applying to shotcrete. PP Fiber can cause a problem in fiber balling during applying to shotcrete railway tunnel construction. A purpose of the research is applying a development of PET(Poly Etylene Terephtalate) fiber by recycling pet bottles to the shotcrete tunnel exposed to explosion spalling. To investigate the reinforcement effect of the PET fiber, some basic tests are accomplished to physical properties and explosion spalling by fire. As a result of the tests, a concrete mixing the PET fiber has stronger resistance effect in the explosion spalling by high temperature than another strong fiber concrete does, and that the former concrete is also equal or more effective on the result of the above tests to physical properties like compression and strain than the latter one is demonstrated.
This study has been performed to investigate the risk perceptions of employees in nuclear power plants. A representative sample of 473 employees was surveyed(about 79% response rate). The questionnaire included scales on both risk perceptions of critical five hazards that could be occurring in the nuclear power plants and two psychometric attitudes. Higher risk perceptions between managers and non-managers to five hazards used in this study were entirely obtained from the managers. It was also found that the perceived higher hazards were in the following order: radiation exposure, radioactive release, explosion, fire and radioactive waste. For the controllability, higher risk perceptions to the all factors were obtained from the managers, and higher ones were non-managers in the dread.
2011년 후쿠시마 원전참사나 2001년 캘리포니아 정전사태 등은 전력관련 대형재난사고로 국가적인 막대한 손실을 가져온 발전소 안전관리의 중요성을 재조명하는 사례로 손꼽고 있다. 인간이 지구상에 살고 있는 한 전기가 없이 살 수 없는 상황에서 원자력, 석탄 및 가스 등 대용량의 위험물질을 연료로 전기를 생산하는 발전소가 안전관리의 소홀로 인한 화재폭발사고나 방사능누출, 최근 이슈가 되고 있는 지진 등 자연재해로부터 국민의 생명과 재산손실예방 및 안정적 경제성장을 위해서도 체계적인 소방안전관리의 강화노력은 절대적으로 필요하다. 따라서 본 연구에서는 국내 전력공급을 책임지고 있는 한국남부발전 등 5개 발전사 및 한수원의 소방안전관계자를 대상으로 발전소 소방안전관리 운영실태를 조사하여 분석을 수행하였으며, 그 결과, 체계적인 발전소 소방안전관리를 위해서는 소방안전경영시스템의 구축을 바탕으로 소방담당자를 위한 실효적인 업무매뉴얼 및 관리시스템의 개발과 소방안전교육의 내실화 및 지진에 대비한 내진설계의 강화를 개선방안으로 도출하였다.
최근 주유취급소 내의 건축물에 편의점, 자동차 수리점 등의 부대시설이 증가하고 있다. 이에 따라 부대시설에서 화재 발생 시 고정주유기에 미치는 화재의 영향을 알아보고 현행 규정의 타당성을 검증할 필요성이 있다. 본 논문에서는 부대시설에서의 화재 시 고정주유기까지의 이격거리에 따라 미치는 복사열의 영향을 알아보는 연구를 진행하였다. FDS 5.5.3을 사용하여 화재모델링을 하였고, 화원의 크기는 실규모 화재평가 장치를 이용한 사무실의 연소실험을 통한 단위면적당 열방출율을 입력하였다. 화원과 고정주유기의 이격 거리는 '위험물안전관리법 시행규칙 별표13 주유취급소의 위치·구조 및 설비의 기준'에서 명시하는 2 m 부터 이격거리를 1 m 간격으로 늘여가며 10 m까지 화원의 크기를 Case A의 경우 512.41 kW/m2, Case B의 경우 250 kW/m2로 설정하여 총 13개의 시나리오를 구성하여 연구를 진행하였다. 시뮬레이션을 통해 2 m의 이격거리는 부대시설의 화재 시에 주유기의 안전성을 확보하지 못하는 것으로 나타났으며 최소 4m 이상의 이격거리에서 복사열이 피해를 미치지 않는 것으로 나타났다. 이에 따라 부대시설의 화재 발생시 복사열을 차단할 수 있는 설비가 필요하며 부대시설의 용도를 제한하거나 건축물과 고정주유기의 이격거리를 다시 제고하는 방안이 필요할 것이다.
산업현장에서 폭발성가스의 사용이 꾸준이 증가 함에 따라 작업자는 물론 일반지역주민들에까지 사고로 인한 생명에 위험을 처하기도 한다. 수소사용공정에서의 사고피해는 공정자체에 국한 되는 것이 아니라 대형화재나 폭발로 이어져 다수의 사상자를 유발시키므로 사고의 유형과 원인을 규명하고 피해규모를 예측하여 이에 대한 안전대책을 수립, 운영하는 것이 필요하다. 본 연구에서는 MLCC(Multi Layer Ceramic Capacitor) 소성공정의 수소저장 사용시설에서 화재 폭발시 위험범위를 예측하였다. 실제 사고데이터의 분석결과 사고발생빈도가 가장 많은 배관누출에 대하여 사고 피해예측 시나리오 모델로 선정, 적용하였다. 10 mm Hole에서 120 Bar의 압력으로 수소가스 누출시 Jet fire가 발생되며 Radiation Level 4($kw/m^2$)의 경우 최대 12.45 m까지 복사열의 영향을 주었다. 또한 사고피해 예측을 통한 안전성확보와 개선방안을 제시하였다.
반도체, 디스플레이 등 IT(Information Technology) 제품 수요 증가로 관련 산업이 확대되고 있다. 이는 생산설비 증설과 화학물질 사용 증가로 이어지며 화재·폭발의 위험성에도 영향을 미치고 있다. 이러한 위험요인에 대해 정부는 오래전부터 인화성 물질을 제조·사용·취급하는 장소의 사고 예방을 위하여 산업안전보건법 및 KS 기준에 따라 폭발위험 장소로 설정하여 관리토록 하고 있다. 그러나, 폭발위험장소를 설정할 때, 중요한 요소인 환기량을 고려하지 않아 실질적인 폭발분위기 조성 가능성을 예측하기는 쉽지 않다. 이 연구에서는 디스플레이 산업에서 주요 공정인 CVD(Chemical Vapor Deposition) 설비에 SEMI S6 Exhaust Ventilation Test 방법을 적용하여 위험한 설비의 환기 성능을 평가하고, 폭발분위기 조성 가능성을 확인하였다. 그 결과, 가상의 시나리오 내에서 환기 성능이 SEMI S6에서 규정한 기준에 적합하였고, 폭발분위기가 조성될 가능성이 낮음을 확인하였다. 따라서, KS 규격뿐만 아니라 공학적 기법으로 폭발분위기의 형성 여부를 예측한 연구 결과를 통해 합리적이고 경제적인 사고 예방에 도움이 될 것으로 기대된다.
Close to high power radio/radar transmitters there is a possibility that sparks may be occur at discontinuities in metallic structures. If these structures are in an area in which a flammable mixture may be present, there is a possibility that a fire or explosion may be caused by the sparking. A number of assessment procedures for quantification of the hazard have been produced. This paper reviews the bases of the British Standard covering ignition hazards by radio-frequency radiation and presents some ignition test apparatus to access these hazards.
Specialty contractor facilities, which involve a combination of welding and commissioning, face a high risk of serious accidents such as fire, explosion, and suffocation associated with welding work, nitrogen, and argon use. In such facilities, the organizational safety culture has considerable impact on the frequency of accidents. In this study, a safety culture evaluation was conducted on specialty contractors. NOSACQ-50, a standardized survey method on safety culture, was selected as an assessment tool to evaluate the safety culture in specialized construction companies that could not afford to invest heavily in safety. The self-administered questionnaire survey was conducted with 201 workers of four construction companies and the results were analyzed. It was found that in companies with low safety culture, the occurrence of irrationality was 66.0%, while in companies with high safety culture, the occurrence of irrationality was 42.6%. Thus, the difference in the occurrence of irrationality by safety culture was statistically significant. The difference in safety culture level according to the experience of occurrence of irrationality was also significant. It was also found that the higher the belief in safety management authorization, safety responsibilities of managers, worker safety priorities, and safety system effects, the lower the probability of irrationality.
Purpose: This study aimed to identify the safety perception and behaviors of mothers with school age children. Method: The subjects were 265 mothers of third graders in one elementary school located in metropolitan Seoul area. Framingham safety survey were used to guide the development of a self administered questionnaire for mothers. The questionnaire were sent home at school and the children returned them to their class teachers. Results: Among 265 mothers, 62 mothers (23.4%) had experience of visiting hospitals because of accidents and 201 mothers (75.8%) had no opportunities on safety education. Mothers with education higher than high school graduation showed more safety behaviors. Also, mothers having the experience of safety education showed higher scores on safety behaviors and mothers with the experience of hospital visits related to accidents showed low scores on safety behaviors. In the practice of safety behaviors, it showed high score to the traffic safety, followed by the home safety, child supervision, the safety from fire and explosion, the safety from electric devices, the safety from burn, and the safety from medicines. Conclusion: Mothers' overall practice on safety were poor. Based on these results, it is necessary to provide more safety education for mothers with school age children.
본 연구에서는 화재폭발 사고의 원인 규명을 위하여 다양한 시험 장비를 사용하여 유기과산화물의 일종인 터셔리부틸퍼옥시말레이트(TBPM)의 분해 및 폭발 위험성을 조사하였다. 시차주사열량(DSC) 분석결과, TBPM의 순간동력밀도(IPD)는 26,401 kW/ml로서 NFPA 반응성지수(Nr)가 4로 분류되었다. 또한 발열량과 개시온도 측정값을 이용한 폭발전달성(EP)과 충격감도(SS)는 양의 값을 나타내며 위험성이 있는 것으로 예측되었으며, 평가 장비를 활용한 실험적 결과로부터 충격감도와 마찰감도는 각각 4급 및 5급으로 평가되었다. 압력용기시험에서는 USA-PVT No.가 4로 분류되어 자기반응성물질에 해당되는 것으로 나타났다. 연소속도에 대한 조사 결과로부터 TBPM은 167 mm/sec의 연소속도를 나타내며 인화성고체 분류2에 포함되는 것으로 평가되었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.