• Title/Summary/Keyword: Fire- and explosion safety

Search Result 403, Processing Time 0.02 seconds

Fire at an Indoor Shooting Range in Busan II. Causes and Fire Safety Measures (부산 실내사격장 화재 II. 원인 및 화재안전대책)

  • Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.92-97
    • /
    • 2010
  • Fire simulation by using a computational fluid dynamics model and examination of the fires at indoor shooting ranges broken out in the past were conducted, to presume causes of the fire at the indoor shooting range in Busan and suggest fire safety measures. On-site investigations and shooting tests on unburned gunpowder were also carried out. No trace of the muzzle spark and spark at the bullet trap was found in CCTV footage, and the impact of a stray bullet failed to ignite gunpowder. Cigarette was therefore presumed to be the most likely source of ignition among the potential sources. It appeared that the explosion in the shooting area was caused by violent burning of the polyurethane sound absorber and unburned gunpowder accumulated on it. The fire safety measures include prohibit of use of profile polyurethane sound absorber, removal of steel components from bullet trap, clean up and control of unburned gunpowder, etc.

A Study on Reasonable Improvement of Legal Requirement for Fire Proofing for Steel Structures in a Chemical Plant (화학플랜트에서 철골구조물 내화기준의 합리적인 개선에 관한 연구)

  • Hwang, Soon-Yong;Char, Soon-Chul;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.51-63
    • /
    • 2007
  • It is noted that the disaster such as fire, explosion, collapse has been rapidly increased caused by strength deterioration of steel structures at petrochemical plant during fire. In this regard, it is stressed out that the legal requirement for fire proofing for steel structures at petrochemical plant should be carefully reviewed since the current legal requirement such as Industrial Safety & Health Law, Architectural Law has a conflict and different way of approach. In addition, it is our point of view that the present law should be revised to consolidate into single law including engineering design criteria to reflect unreasonable legal requirement. It is further our point of view that the performance certificate for fire proofing like UL-1709, basis of maintenance should be appropriately and reasonably provided in line with global practice.

Prediction of Temperature Dependence of Explosion Limits and Interrelationship of Explosion Characteristics for Akylketones (알킬케톤류의 폭발 특성치 간의 상관관계 및 폭발한계의 온도의존성 예측)

  • Ha Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.2 s.31
    • /
    • pp.7-13
    • /
    • 2006
  • In order to evaluate the fire and explosion involved and to ensure the safe and optimized operation of chemical processes, it is necessary to know combustion characteristics. The explosion limit, the heat of combustion, flame temperature and temperature dependence of the lower explosive limit are the major combustion characteristics used to determine the fire and explosion hazards of the flammable substances. The aim of this study is to investigate interrelationship of explosion characteristics and the temperature dependence of the lower explosion limit at elevated temperature for akylketones. By using the reference data, the empirical equations which describe the interrelationships of explosion properties of akylketones have been derived. Also, the new equations using the mathematical and statistical methods for predicting the temperature dependence of lower explosion limits of akylketones on the basis of the literature data are proposed. The values calculated by the proposed equations agreed with literature data within a few percent. From the given results, using the proposed methodology, it is possible to predict the explosion limits of the other flammable substances.

  • PDF

The Measurement and Prediction of the Fire and Explosion Properties of Isoamyl alcohol (이소아밀알코올의 화재 및 폭발 특성치의 측정 및 예측)

  • Ha, Dongmyeong
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.34-40
    • /
    • 2016
  • For the safe handling of isoamyl alcohol being used in various ways in the chemical industry, the flash point and the autoignition temperature(AIT) of isoamyl alcohol was experimented. And, the lower explosion limit of isoamyl alcohol was calculated by using the lower flash point obtained in the experiment. The flash points of isoamyl alcohol by using the Setaflash and Pensky-Martens closed-cup testers measured $31^{\circ}C$ and $33^{\circ}C$, respectively. The flash points of isoamyl alcohol by using the Tag and Cleveland open cup testers are measured $43^{\circ}C$and $45^{\circ}C$. The AIT of isoamyl alcohol by ASTM 659E tester was measured as $419^{\circ}C$. The lower explosion limit by the measured flash point $31^{\circ}C$ was calculated as 0.87 vol%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.

Multi-Objective Optimization Study of Blast Wall Installation for Mitigation of Damage to Hydrogen Handling Facility (수소 취급시설 피해 저감을 위한 방호벽 설치 다목적 최적화 연구)

  • Se Hyeon Oh;Seung Hyo An;Eun Hee Kim;Byung Chol Ma
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.6
    • /
    • pp.9-15
    • /
    • 2023
  • Hydrogen is gaining attention as a sustainable and renewable energy source, potentially replacing fossil fuels. Its high diffusivity, wide flammable range, and low ignition energy make it prone to ignition even with minimal friction, potentially leading to fire and explosion risks. Workplaces manage ignition risks by classifying areas with explosive atmospheres. However, the effective installation of a blast wall can significantly limit the spread of hydrogen, thereby enhancing workplace safety. To optimize the wall installation of this barrier, we employed the response surface methodology (RSM), considering variables such as wall distance, height, and width. We performed 17 simulations using the Box-Behnken design, conducted using FLACS software. This process yielded two objective functions: explosion likelihood near the barrier and explosion overpressure affecting the blast wall. We successfully achieved the optimal solution using multi-objective optimization for these two functions. We validated the optimal solution through verification simulations to ensure reliability, maintaining a margin of error of 5%. We anticipated that this method would efficiently determine the most effective installation of a blast wall while enhancing workplace safety.

Consequence Analysis of Hydrogen Blended Natural Gas(HCNG) using 3D CFD Simulation (CFD를 활용한 수소-천연가스 혼합연료에 대한 피해영향 분석)

  • Kang, Seung-Kyu;Bang, Hyo-Jung;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.15-21
    • /
    • 2013
  • This study evaluated comparison of the risk according to the type of fuel by three-dimensional simulation tool(FLACS). The consequence analysis of fire explosion and jet-fire was carried out in the layout of a typical high-pressure gas filling stations using CNG, hydrogen and 30%HCNG. Under the same conditions, hydrogen had a 30kPa maximum overpressure, CNG had a 0.4kPa and HCNG had a 3.5kPa. HCNG overpressure was 7.75 times higher than the CNG measurement, but HCNG overpressure was only 11.7% compared to hydrogen. In case of flame propagation, hydrogen had a very fast propagation characteristics. On the other hand, CNG and HCNG flame propagation velocity and distance tended to be relatively safe in comparison to hydrogen. The estimated flame boundary distance by jet-fire of hydrogen was a 5.5m, CNG was a 3.4m and HCNG was a 3.9m.

An Availability Assessment of Protection Wall Installed in LPG Filling Station (LPG 충전소 내 설치된 방호벽의 효용성 평가)

  • Lee, Jin-Han;Jo, Young-Do;Moon, Jong-Sam;Kim, Lae Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.38-45
    • /
    • 2018
  • Jet fire, pool fire, and vapor cloud explosion are major accident scenarios in LPG filling station. The protection wall would mitigate radiation effect in a jet fire. In case of a pool fire, the protection wall would restrict expanding the pool area. The protection wall might both obstruct the dispersion of released vapor and protect blast overpressure in a vapor cloud explosion scenario. In this paper, An availability assessment method of the protection wall how much reduce damage to receptors is proposed. Additionally application cases are presented for the effectiveness of protection wall in the LPG filling station. The study shows that the protection wall can effectively reduce the death probabilities of receptors located behind the wall in cases of the jet fires and the vapor cloud explosions.

A Study on the Building Plan of Chemical Management System in Laboratory Using FGI Method (FGI 기법을 이용한 연구실에서의 화학물질관리시스템 구축 방안에 관한 연구)

  • Kim, Sang-Chul;Song, Young-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.18-25
    • /
    • 2017
  • Each country tries to prevent major industrial accidents at industrial sites, such as fire and explosion as well as poisoning incidents, and regulation of the management of chemicals is being enhanced in all sectors. In particular, in the case of laboratories, a variety of chemicals have been developed and handled in accordance with the development of science and technology. On the other hand, the accident probability at laboratories is higher than at industrial sites, because many different kinds of chemicals are handled in the laboratory but in very small amounts and chemical, physical, and biological studies have been carried out in limited spaces. Recently, the accident probability at laboratories was found to be higher as convergence/integration studies were carried out beyond the academic arena. Therefore, in this study, a survey of chemical management was conducted to prevent accidents due to chemicals targeting the laboratory safety coordinator using the FGI (focus group interview) method. The building plan of a chemical management system was suggested based on the results of the survey.

Risk Assessment and Safety Measures for Methanol Separation Process in BPA Plant (BPA 공장의 메탄올 분리공정에서 위험성 평가 및 안전대책)

  • Woo, In-Sung;Lee, Joong-Hee;Lee, In-Bok;Chon, Young-Woo;Park, Hee-Chul;Hwang, Seong-Min;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.22-28
    • /
    • 2012
  • For a methanol separation column of the BPA (Bisphenol A) plant, HAZOP (hazard and operability) assessment was performed and damage ranges were predicted from the accident scenarios for the fire and the explosion. As a result, the damage range of the jet fire was 20 m in the case of rupture of the discharge pipe (50 mm diameter) of safety valve, and that of the flash fire was 267 m in the case of catastrophic rupture. Also, the damage ranges of the unconfined vapor cloud explosion (UVCE) for the rupture of the discharge pipe and for the catastrophic rupture were 22 m and 542 m, respectively. For the worst case of release scenarios, safety measures were suggested as follows: the pressure instruments, which can detect abnormal rise of the internal pressure in the methanol separation column, should be installed by the 2 out of 3 voting method in the top section of the column. Through the detection, the instruments should simultaneously shut down the control and the emergency shut-off valves.