• Title/Summary/Keyword: Fire system

Search Result 3,377, Processing Time 0.032 seconds

A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings (현행소방시설설치기준의 분석과 개선방안에 관한 연구)

  • 정병재;이경회
    • Fire Science and Engineering
    • /
    • v.4 no.2
    • /
    • pp.3-13
    • /
    • 1990
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the ]after fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern Higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First. We are going to look history of the fire protection system and change course of that with the year and facility. Second, We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

Part II A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings (현행소방시설설치기준의 분석과 개선방안에 관한 연구II)

  • 정병재;이경회
    • Fire Science and Engineering
    • /
    • v.5 no.1
    • /
    • pp.5-14
    • /
    • 1991
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it Is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the latter fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First, We are going to look history of the fire protection system and change course of that with the year and facility. Second. We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have to reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use count about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

The Development of Fire Detection System Using Fuzzy Logic and Multivariate Signature (퍼지논리 및 다중신호를 이용한 화재감지시스템의 개발)

  • Hong, Sung-Ho;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2004
  • This study presents an analysis of comparison of P-type fire detection system with fuzzy logic-applied fire detection system. The fuzzy logic-applied fire detection system has input variables obtained by fire experiment of small scale with K-type temperature sensor and optical smoke sensor. And the antecedent part of fuzzy rules consists of temperature and smoke density, and the consequent part consists of fire probability. Also triangular fuzzy membership function is used for input variables and fuzzy rules. To calculate the final fire probability a centroid method is introduced. A fire experiment is conducted with controlling wood crib layer, cigarette to simulate actual fire and false alarm situation. The results show that peak fire probability is 25[%] for non-fire and is more than 80[%] for fire situation, respectively. The fuzzy logic-applied fire detection system suggested here is able to distinguish fire situation and non-fire situation very precisely.

FIRE WATER SYSTEM RELIABILITY IN INDUSTRIAL APPLICATIONS

  • James M. Dewey;Kim, Yong-Dal
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.526-533
    • /
    • 1997
  • Reliability of fire protection systems is often discussed, written about, and even put into codes and standards. However, reliability is seldom considered for the fire protection system as a whole. Why does this happen and why should the designer consider the system as a whole\ulcorner Existing codes and standards incorporate the concept of reliability usually In the form of key component redundancy for some parts of a system. The "Fire Safety Concepts Tree" presented in the National Fire Protection Association Guide 550, Guide to the Fire Safety Concepts Tree, provides a starting point for considering the performance of a water based fire suppression system. Considering fire protection objectives for water based fire suppression systems, means of evaluating system reliability can be developed. This development requires identification of system components that are significant to the overall system reliability.

  • PDF

Development of Performance Index for Ubiquitous Building Fire Safety System - Focused on Sprinkler System - (유비쿼터스 건물 화재안전시스템을 위한 성능지수 개발 - 스프링클러 시스템을 중심으로 -)

  • Kim, Jong-Hoon;Roh, Sam-Kew
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.23-30
    • /
    • 2009
  • For managing fire safety system in building by ubiquitous management system, the index system to express the performance level of fire protection system is demanded. If some component formed fire protection system such as sprinkler water supply system is breakdown, that will fall down the performance of fire protection capacity. Consequently, it will affects the level of fire safety of building management and energy response. Consequently, Building fire protection system could give performance level of fire protection condition and the level of fire safety in building. It will also contribute to the development of wide area fire safety management. This development of index system has been developed as a part of the development project of Ubiquitous building fire management system.

A Study on Efficient Improvement Ways of Fire Protection Management System (방화관리제도의 효율적 개선방안에 관한 연구)

  • Kook, Hyeong-Ho;Jo, Dae-Ho;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.115-127
    • /
    • 2008
  • Fire protection management system has been introduced to prevent structure fire since establishment of Fire Prevention Act. Nevertheless, Damage by fires is continue. The main purpose of this study is to discuss approaches to improve fire protection management system into the fire prevention properties. Now fire protection management system has lots of the problems in managerial and systematical aspects. To improve these a unified fire protection management system must be establish by suggests revision of a unified Fire Prevention Act and foundation of Fire Prevention Institution, reform educational system for the fire safety directors would be essential to includes environment improvement, enhancement of certification requirements and education, a standardized computational management system of the fire protection properties must be build for efficient fire protection operations.

Development of U-Building Fire Safety Management System (U-건물 화재안전관리 시스템 개발)

  • Kim, Jong-Hoon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.74-80
    • /
    • 2016
  • Ubiquitous computer technology (U technology) is continually, and the trend is moving towards the miniaturization of devices, cost reduction, performance enhancement, and intelligence. It is important to improve fire safety system by the application of advanced IT technologies. In this study, a vulnerable point in fire safety was selected for improvement by U technology. The structure of the whole system and a unit system was were designed. This system is divided into 5 parts: the U-fire protection facility management system, the U-fire safety information system, the U-fire safety education system, the U-fire response system, and the U-wide area fire safety management system. The prototype system was constructed in a real building to confirm the applicability of the system.

The Study of Promotion for Fire Assessment System (화재영향 평가 제도화 추진에 관한 연구)

  • 김광일;윤명오
    • Fire Science and Engineering
    • /
    • v.10 no.1
    • /
    • pp.25-43
    • /
    • 1996
  • This paper has been studied about promotion system for fire assessment. Mainly system carried out for BCJ (Building Center of Japan) and JFSC (Japan Fire Safety Center) fire risk assessment system. Much of the work of fire science and fire protection engineering is now explicitly designed to fill gaps or improve accuracy or flexibility In some comprehensive fire hazard or fire risk models.

  • PDF

A Study on the Policy Tasks for the Development of National Fire Service - Redesigning Institutional and Organizational Improvement for the Establishment of the National Fire Service Agency - (한국소방발전을 위한 정책과제 연구 - 소방청 신설에 대응하는 제도·조직개선 구상 -)

  • Choi, Byoung-Hahk;Kim, Hak-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.185-197
    • /
    • 2002
  • Today, the basic problem of functional safe management of Korean Disaster Control system was separately administrated 33 acts that are relating to safe management in 13 ministries. Because of the facts that the fire service is not provided practically, the control system and risk management for safe administration are not operated, the information can not be shared with each other, and the various laws have the lacks of linkage, the National Safe System was appeared unsteady. The roles and functions of fire service have started with restriction to operate structurally and institutionally, which operational structure of fire service is becoming weak. As a result, the federal and local fire organizations have not reached yet to the institutionalization and the local fire service agencies have bias with the task regarding the fire service because of the relation between organizational structure and the local fire agency. With the enforcement of the federal and local fire system, professionality and autonomy for making policy, and dealing with changes of fire service positively, the national fire service on the policy performance can be established. Promotion of research and development and education training to strengthen innovation in technology and competition in fire industry will contribute to the firmly establishment of control system to prevent from fire, flood, terror and national disaster. This article proposed that (a) the established law and administration, agency are required efforts to effectively operate fire service system; (b) the national fire service agency, national college of fire, national institute of science fire, and national fire service hospital should be early established to make firmly policy to operate effectively and practically. These kinds of innovational acts are known the best ways of operating solid policy of national fire service system.

  • PDF

Development of a Novel Real-Time Monitoring System Algorithm for Fire Prevention (화재예방을 위한 실시간 모니터링 시스템의 알고리즘 개발)

  • Kim, Byeong-Jo;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.47-53
    • /
    • 2014
  • Despite the automatic fire alarm system, according to the national fire data system of national emergency management agency, the fires account for 40,932 incidents, 2,184 injuries and about 430 billion won in property losses in 2013. Since the conventional automatic fire alarm system has several weaknesses related to electrical signal such as noise, surge, lighting, etc. Most fires are mainly caused by electrical faults, mechanical problem, chemical, carelessness and natural. The electrical faults such as line to ground fault, line to line fault, electrical leakage and arc are one of the major problems in fire. This paper describes the development of a novel real-time fire monitoring system algorithm including fault detection function which puts the existing optic smoke and heat detectors for fire detection with current and voltage sensors in order to utility fault monitoring using high accuracy DAQ measurement system with LabVIEW program. The fire detection and electrical fault monitoring with a proposed a new detection algorithm are implemented under several test. The fire detection and monitoring system operates according to the proposed algorithm well.