• 제목/요약/키워드: Fire spread prevention

검색결과 96건 처리시간 0.02초

Meteorological Determinants of Forest Fire Occurrence in the Fall, South Korea

  • Won, Myoung-Soo;Miah, Danesh;Koo, Kyo-Sang;Lee, Myung-Bo;Shin, Man-Yong
    • 한국산림과학회지
    • /
    • 제99권2호
    • /
    • pp.163-171
    • /
    • 2010
  • Forest fires have potentials to change the structure and function of forest ecosystems and significantly influence on atmosphere and biogeochemical cycles. Forest fire also affects the quality of public benefits such as carbon sequestration, soil fertility, grazing value, biodiversity, or tourism. The prediction of fire occurrence and its spread is critical to the forest managers for allocating resources and developing the forest fire danger rating system. Most of fires were human-caused fires in Korea, but meteorological factors are also big contributors to fire behaviors and its spread. Thus, meteorological factors as well as social factors were considered in the fire danger rating systems. A total of 298 forest fires occurred during the fall season from 2002 to 2006 in South Korea were considered for developing a logistic model of forest fire occurrence. The results of statistical analysis show that only effective humidity and temperature significantly affected the logistic models (p<0.05). The results of ROC curve analysis showed that the probability of randomly selected fires ranges from 0.739 to 0.876, which represent a relatively high accuracy of the developed model. These findings would be necessary for the policy makers in South Korea for the prevention of forest fires.

Introduction of Fire Research in China

  • Weicheng, Fan
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.35-43
    • /
    • 1997
  • Fire research is urgently needed so as to mitigate fire damage with moderate costs. A system of fire research consisting of basic research, applied research and development of new technology for fire prevention and protection is being formed in China. A general structure of organizations related to fire research is outlined. Typical research work in the State Key Lab of Fire Science is given as an example of fire research in China including: Field-Zone-Network modeling of building fire, mechanism of boilover, forest fire behavior, computer modeling of fire spread in micsogravity, and duality of fire rules and its application.

  • PDF

AES 계열 덕트·배관 단열재의 내화성능 검증에 관한 연구 (A Study on the Refractory Performance Verification of the Thermal Insulators for AES Ducts and Piping)

  • 함광호;사재천;이주환;민세홍
    • 한국재난정보학회 논문집
    • /
    • 제20권2호
    • /
    • pp.419-429
    • /
    • 2024
  • 연구목적: 소방용 배관 보온재의 불연성능 강화와 제연덕트 보온재의 내열성능 향상을 위해 AES소재 단열재의 성능을 시험을 통해 배관보온재 및 제연덕트 보온재에 적합성을 검증하고자 한다. 연구방법: AES 단열재에 대해 불연성능과 내열성능, 단열성능을 시험을 통해 검증한다. 연구결과: '건축물 마감재료의 난연성능 및 화재 확산 방지구조 기준'에 근거하여 불연성 및 가스 유해성 시험 결과 불연성능을 확인하였고, 내화성능 표준시험 결과 내화성능도 확인하였다. 또한, 건축용 단열시험으로 단열성능도 검증하였다. 결론: 본 연구에서 AES 계열 무기질 성분 단열재에 대한 성능시험으로 불연성능, 내화성능, 단열성능이 입증됨에 따라 건축물의 화재확산 방지성능을 개선하는데 좋은 대안이 될 것으로 사료된다.

An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권4호
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.

화재 시 승강기를 이용한 피난에 관한 연구 (A Study on escape using elevators in fire emergency)

  • 정의수
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2007년도 추계학술대회
    • /
    • pp.55-68
    • /
    • 2007
  • Because of not accepted on escape using elevators in fire emergency has some background. In the background elevator hoistway has turn into smoke spread route in fire. The escape that used an elevator was not able to make ends meet; of the big confusion is expected that cannot control the escape adequately, and do that elevator facilities breakdown possibility by the fire water, the escaper shut in car. Therefore ban on elevator service in fire time as a general rule. Recently, a few company promote super high-rise architecture in the country, a fire disaster prevention and human life safety measures preparation for PBD(A Performance Based Fire Protection Design) are studied concretely. And there is the escape example in fire time that used an elevator in the foreign country. You must promote it so that the escape measures that used enclosed stairway and an elevator in charge of a function of the mutual supplement. The result of this research can be used for establishing the standard and regulation for using elevators in fire emergency.

  • PDF

중복도형 인텔리전트빌딩 화재시 연기제어를 통한 피난안전성 확보에 관한 연구 (A Study on Securing Safety of Evacuation through Smoke Control in Case of Fire at the Central Corridor Type Intelligent Buildings)

  • 민세홍;이재문;배연준
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.117-127
    • /
    • 2015
  • This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.

해저터널 구난역 플랫폼 화재연기확산 방지를 위한 에어커튼 시스템 차연성능 시뮬레이션 연구 (Simulation study of smoke spread prevention using air curtain system in rescue station platform of undersea tunnel)

  • 박상헌;안승주;한상주;유용호
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.257-266
    • /
    • 2015
  • 본 연구는 국내에서 계획하고 있는 호남-제주간 초장대 해저터널에서 철도차량의 화재 발생시 구난역 (Rescue Station)에 정차후 대피자의 안전한 대피경로를 확보하고 플랫폼 내부에 연기가 유입되는 것을 방지하기 위해 구난역 플랫폼과 화재열차 사이에 에어커튼 시스템(Air curtain system)을 설치하여, 15MW급 화재연기에 대한 차단성능 및 최적화방안을 도출하기 위해 다양한 시뮬레이션을 수행하였다. 시뮬레이션 결과, 모든 CASE에서 15 MW급 화재강도에 발생되는 연기에서도 효과적인 차연성능을 발휘하였으며, CASE1(화재열차 방향으로 15도 분사)와 CASE5(화재열차 방향으로 15도 분사 + 가압송풍)가 구난역 플랫폼 내부에 CO가스 유입이 가장 적은 것으로 도출하였다. 이러한 결과를 통하여 에어커튼 시스템은 초장대 해저터널 구난역에 화재시 플랫폼에 화재연기가 유입되지 않고 안전한 대피 경로를 확보하여 대피자가 서비스 터널로 안전하게 대피하여 인명피해를 최소화 할 수 있는 방재시설로서 활용되기를 기대한다.

건축물 외장재의 화재확대방지를 위한 보수구법 및 보수재료 검토에 관한 연구 (A Study on the Review of Repair Methods and Repair Materials for the Prevention of Fire spread of Building Exterior Materials)

  • 이병흔;진승현;박성하;권영진
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.105-111
    • /
    • 2019
  • 국내의 경우 2018년도에 시행한 가연성 외장재 설치 건축물 현황조사결과 147,559동의 건축물이 이에 해당되는 것으로 조사되었으며, 상층부 및 인접건축물로의 화재확대사례는 연간 약 3,500건, 외장재에서 시작한 화재건수는 연간 약 1,500건 이상 발생하는 등 의정부 화재, 제천스포츠센터 화재와 같은 유사한 화재발생의 위험성이 내포되어 있다. 본 연구에서는 유사한 화재 재발방지를 위해 가연성 외장재가 시공된 건축물의 보수공법에 대해 조사하고 각각의 보수재료 성능검증을 실시하였다. 보수방법의 경우 기존의 건축물 마감재를 제거한 뒤 보수재료로 보강하는 방법과 기존 마감재를 제거하지 않고 면고르기를 실시한 뒤 보수재료를 부착하는 방법을 제안했다. 또한 드라이비트 및 보수재료로서 방화석고보드, 미네랄 울, 경질우레탄 폼, 세라믹보드, ALC 패널 등 6가지 재료를 대상으로 콘 칼로리미터 시험을 실시하고 해당 재료들에 대한 기초 연소 성능을 조사하였다.

건축용 바닥재의 연소성능 시험 (Burning Tests for Interior Flooring Materials)

  • 이봉우;이장원;사공성호;김희수;이병호;김현중
    • 한국화재소방학회논문지
    • /
    • 제22권2호
    • /
    • pp.30-37
    • /
    • 2008
  • 건축용 바닥재의 화재예방을 위하여 국제규격으로 정해져 있는 바닥재 시험평가 방법인 KSISO 9239-1을 이용하여 각종 바닥재에 대한 연소성 시험을 복사열 판넬 시험기를 사용하여 실시하였다. 복사열 판넬 시험기를 이용하여 각종 바닥재에 대한 화염 전파거리, 임계 열류량 그리고 연기 발생농도 측정하였다. 측정결과 바닥재의 구성 물질 별로 서로 다른 연소특성을 나타내었으며, 바닥재의 표면 재질 및 구성성분이 열 방출과 연기 발생량에 있어 중요한 영향을 미치게 된다는 것을 확인할 수 있었다. 위의 평가방법은 화재위험성을 연구하는데 중요한 인자인 임계 열류량, 연기 발생량 및 화염 전파거리를 정량적으로 평가하는 중요한 시험방법임을 알 수 있었고 국내 건축용 바닥재 화재평가 방법을 국내실정에 맞게 제정 및 적용하는 것이 적합할 것으로 판단되었다.

지하공동구 화재예방활동 및 진압대책에 관한 연구 (A Study on the Fire Prevention Activities and Suppression Measures of Utility-Pipe Conduit)

  • 이정일
    • 한국방재학회 논문집
    • /
    • 제10권4호
    • /
    • pp.63-68
    • /
    • 2010
  • 지하공동구는 도시 및 공동주택 단지에 반드시 필요한 전력, 통신, 가스, 송유관, 급 배수, 에너지시설 등을 효과적으로 수용하고 도시기반시설의 확장에 따라 파생되는 여러 가지의 문제점을 해결하기 위한 방안으로 시설물을 한곳으로 모아 유지 및 관리하는 시설이다. 지하공동구가 훼손될 경우 국가안보는 물론 사회전반에 미치는 파장이 지대하므로 화재예방 활동 및 진압대 책상 취약점 등을 분석하여 우리 실정에 맞는 방재 대책을 도출하여 공동구의 설계, 제도적인 문제, 방화시설의 문제, 화재확산현상 등을 분석하여 종합적인 화재위험을 분석하여 화재예방활동과 진압대책을 수립하여야 한다. 지하공동구는 밀폐 폐쇄된 공간이므로 산소공급 부족으로 인한 불완전 연소 등으로 농연, 일산화탄소 등 유독성연소생성물의 발생과 열기의 충만 및 시야장해로 진입이 곤란 하는 문제점이 있다. 이러한 현상은 지상화재보다는 지하 화재의 특수성에 비추어 볼 때 화재예방활동은 물론이고 소방전술에서 취약하므로 화재의 효율적인 소방전술이 되기 위해서는 화재의 특이성을 감안하여 유관기관에서는 현장대응 지휘체제를 확립하고, 대응기관에서는 평상시 공동구에 대한 구조파악과 필요한 각종 정보를 수집 기록하고 24시간 관리공조체제 유지 및 대응기관에서 가상종합훈련을 강화하여야하며 근본적으로 공동구내에 설치되어 있는 케이블의 난연화 불연화 및 연소 확대 방지를 위한 대책 등이 필요하다.