• Title/Summary/Keyword: Fire spread prevention

Search Result 96, Processing Time 0.022 seconds

Installation Standards of Urban Deep Road Tunnel Fire Safety Facilities (도심부 대심도 터널의 방재시설 설치 기준에 관한 연구(부산 승학터널 사례를 중심으로))

  • Lee, Soobeom;Kim, JeongHyun;Kim, Jungsik;Kim, Dohoon;Lim, Joonbum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.727-736
    • /
    • 2021
  • Road tunnel lengths are increasing. Some 1,300 tunnels with 1,102 km in length had been increased till 2019 from 2010. There are 64 tunnels over 3,000 m in length, with their total length adding up to 276.7 km. Safety facilities in the event of a tunnel fire are critical so as to prevent large-scale casualties. Standards for installing disaster prevention facilities are being proposed based on the guidelines of the Ministry of Land, Infrastructure and Transport, but they may be limited to deep underground tunnels. This study was undertaken to provide guidelines for the spacing of evacuation connection passages and the widths of evacuation connection doors. Evacuation with various spacing and widths was simulated in regards to evacuation time, which is the measure of safety, using the evacuation analysis simulation software EXODUS Ver.6.3 and the fire/smoke analysis software SMARTFIRE Ver.4.1. Evacuation connection gates with widths of 0.9 m and 1.2 m, and spacings of 150 m to 250 m, were set to every 20 m. In addition, longitudinal slopes of 6 % and 0 % were considered. It was determined to be safe when the evacuation completion time was shorter than the delay diffusion time. According to the simulation results, all occupants could complete evacuation before smoke spread regardless of the width of the evacuation connection door when the longitudinal slope was 6 % and the interval of evacuation connection passage was 150 m. When the evacuation connection passage spacing was 200 m and the evacuation connection gate width was 1.2 m, all occupants could evacuate when the longitudinal slope was 0 %. Due to difference in evacuation speed according to the longitudinal slope, the evacuation time with a 6 % slope was 114 seconds shorter (with the 190 m connection passage) than with a 0 % slope. A shorter spacing of evacuation connection passages may reduce the evacuation time, but this is difficult to implement in practice because of economic and structural limitations. If the width of the evacuation junction is 1.2 m, occupants could evacuate faster than with a 0.9 m width. When the width of a connection door is 1.2 m with appropriate connection passage spacing, it might provide a means to increase economic efficiency and resolve structural limitations while securing evacuation safety.

Design of detection method for smoking based on Deep Neural Network (딥뉴럴네트워크 기반의 흡연 탐지기법 설계)

  • Lee, Sanghyun;Yoon, Hyunsoo;Kwon, Hyun
    • Convergence Security Journal
    • /
    • v.21 no.1
    • /
    • pp.191-200
    • /
    • 2021
  • Artificial intelligence technology is developing in an environment where a lot of data is produced due to the development of computing technology, a cloud environment that can store data, and the spread of personal mobile phones. Among these artificial intelligence technologies, the deep neural network provides excellent performance in image recognition and image classification. There have been many studies on image detection for forest fires and fire prevention using such a deep neural network, but studies on detection of cigarette smoking were insufficient. Meanwhile, military units are establishing surveillance systems for various facilities through CCTV, and it is necessary to detect smoking near ammunition stores or non-smoking areas to prevent fires and explosions. In this paper, by reflecting experimentally optimized numerical values such as activation function and learning rate, we did the detection of smoking pictures and non-smoking pictures in two cases. As experimental data, data was constructed by crawling using pictures of smoking and non-smoking published on the Internet, and a machine learning library was used. As a result of the experiment, when the learning rate is 0.004 and the optimization algorithm Adam is used, it can be seen that the accuracy of 93% and F1-score of 94% are obtained.

A Case Study on Performance Analysis of Antimicrobial Copper Film Attaching to Window for Responding to COVID-19 and Others (코로나19 등 대응을 위한 "유리창 부착용 항바이러스 동필름" 성능분석 사례연구)

  • Kim, Seong Je
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.1
    • /
    • pp.23-40
    • /
    • 2021
  • In the era of the global coronal 19 pandemic, there is a risk of cross-infection in hospitals at the stage where treatments and vaccines are currently being developed and marketed, so individuals should enhance their acquired immunity and generalize their living systems by the performance of copper ions in the social environment. In order to prevent the spread of infection, the need for anti-bacterial film and its efficacy were analyzed through anti-viral performance tests based on research and development cases of worldwide and immemorial time. he Korea Construction Research Institute (KCL) has received anti-bacterial performance certification and anti-viral test scores from the "National Approval Performance Certification Agency." At the time, NCCP 43326 Human Corona virus (BetaCoV/Korea/KCDC03/2020), which was approved by the Centers for Disease Control and Prevention, was introduced to ensure that the activity rate of infected cells was satisfied in the anti-viral performance test. Anti-proliferation measures for the Corona 19 virus require a quality clinical trial study comparing the experimental group within the glass space where the antiviral copper film is constructed with the comparator of the same condition without copper film.

Establishment of Complex Disaster Scenario on the Utility Tunnel Study for Digital Twin System Application (디지털트윈 시스템 적용을 위한 공동구 복합재난 시나리오 구축)

  • Yon Ha Chung; So Dam Kim;Hyun Jeong Seo;Hojun Lee;Tae Jung Song
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.861-872
    • /
    • 2022
  • The purpose of this study was to establish a complex disaster scenario that can comprehensively consider various disaster situations that may occur in the utility tunnel. Method: In order to comprehensively consider the correlation between disasters, a composite disaster scenario was derived from a combination of damage factors, respectively. A risk assessment was performed in order to derive the priorities of the scenarios. And based on the results, the priorities of complex disaster scenarios were set. Result: Based on the disaster cases in the utility tunnel, a plan was prepared for complex disaster scenarios centered on damage. A complex disaster scenario was specified using a semi-quantitative evaluation method for single and multiple disaster factors such as fire, flooding, and earthquake. Conclusion: The composite disaster scenario derived from this study can be used for the prevention and preparation of damage when the precursor symptoms of a disaster are detected. In addition, the results of this study are expected to be used as basic data for preparing strategic plans and preparing complex disaster response technologies to induce rapid response and recovery in case of emergency disasters.

A Study on the Development Plan for Promotion of Advanced Disaster-Safety Awareness (선진 재난안전의식의 활성화를 위한 방안 연구)

  • Lee, Jong-hyun;Kim, Mi-ra;Ko, Jae-chul
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.415-426
    • /
    • 2021
  • Purpose: The purpose of this study is to create the deveopment plan for promotion of advanced disaster-safety awareness, which is noted as a major factor in the large disaster. Method: This study is to conduct theoretical review with regard to disaster management and safety awareness. Consciousness surveys on safety awareness and previous disaster case was analyzed to derive the cause of the disaster, and the development plan for promotion of advanced disaster-safety awareness was suggested. Result: In the survey on the public's sense of safety on the disaster management evaluation, 'Response' stage was well performed, but the 'Recovery' stage was not. Especially, it was found that disaster safety education at the 'Prevention' stage was very lacking. In the survey on the public's safety awareness, the awareness level of the evacuation facility was very low, information on infectious diseases and collapse accident was insufficient. Especially, it has been found that the awareness on safety regulation in daily life is very insufficient. Through the case study on previous disaster(COVID-19, Fire in Miryang Sejong Hospital, Forest fire in the east coas at 2004'), it was derived that the lack of safety awareness(such as safety insensitivity) was the main factor of the expansion of the damage scale. Conclusion: The development plan for promotion of advanced disaster-safety awareness are as follow. First, it is necessary to spread the safety culture movement through the expansion of safety education and safety promotion. Second, disaster confrontation training for the public should be implemented to improve the effectiveness of disaster response. Finally, it is necessary to change the individual awareness on safety. When these factors are implemented systematically, advanced disaster-safety awareness can be promoted. Ultimately, disaster accidents in our society can be reduced.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.