• Title/Summary/Keyword: Fire safety law

Search Result 159, Processing Time 0.022 seconds

A Study on Evacuation Safety of a Long-term Care Hospital (요양병원의 피난안전에 관한 연구)

  • Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.3
    • /
    • pp.389-393
    • /
    • 2023
  • In this study, We analyzed that evacuation characteristics of residents, fire safety standards, evacuation facilities and flame retardation, etc to increase the evacuation safety of a long-term care hospital. Therefore, In order to improve of evacuation safety in case of fire, We proposed that an increase in the number of care workers, education, training and an amendment to the law, a change of positions of fire safety controller.

A Study on the Fire Prevention of the Construction Sites (건설현장 화재예방에 관한 연구 - 용접작업을 중심으로 -)

  • Mok, Yun-Soo;Chang, Seong-Rok;Lee, Young-Seob;Go, Seong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.69-75
    • /
    • 2002
  • Current fire safety in the construction sites has developed piecemeal over a considerable period of time. However, the law and regulation of fire safety is insufficient to protect fro in the construction sites. The frequency of fire in the construction sites is very rare but it brings longterm deterioration durability of building structure and large scale industrial calamity. There are many process of works and each work deals with many kind of flammable material, so it is very difficult to find a proper safety fire prevention. This study executed the questionnaire and fire experiment of the welding work to provide effective fire prevention counterplan.

Proposal of Legislation of Smoke Compartment for Prevention and Control of Smoke Diffusion in Buildings (건축물의 연기확산 방지 및 제어를 위한 방연구획의 법제화 제안)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Kim, Hye-Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.96-97
    • /
    • 2019
  • According to building law, there are only regulations on the fire prevention compartments that can perform the function of partial smoke compartment, but the building law management of the smoke compartment for effective smoke diffusion prevention and control is not possible. The lack of control on the smoke compartment such as leakage rate on the penetrating part, and the lack of leakage rate in the design of smoke control of fire safety law resulted in the absence of fundamental safety technology. Therefore, this study seeks to find solutions to domestic problems after reviewing relevant domestic laws and regulations.

  • PDF

Analysis of evacuation time for New publicly used establishments according to whether safety facilities, etc. are installed

  • Hong-Sang Lee;Ha-Sung, Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.49-59
    • /
    • 2023
  • In accordance with the revision of "Special act on the safety control of publicly used establishments", this study is aim to measure the change in evacuation time due to whether safety facilities, etc. are installed of a room escape cafe business and kids cafe business(hereinafter referred to as "New publicly used establishments"), which were added as new targets of the publicly used business from June 8, 2022. In the case of new publicly used establishments or publicly used establishments whose owners are changed after the revision of the relevant laws, safety facilities, etc. are installed and maintained under the "Special act on the safety control of publicly used establishments", but in the case of existing businesses that have been operating even before the revision of the law, the business continues without safety facilities, etc. installed because the revised law is not retroactively applied. The purpose of this study is to compare and analyze the change in evacuation time by measuring the evacuation time to operating before the revision of the law to simulate evacuation at existing new publicly used establishments without safety facilities, etc. and measure the evacuation time at new publicly used establishments with safety facilities after the revision of the law

A Study on Development of Assessment Criteria for Safety City of Fire Fighting Area (소방방재분야의 안전도시 평가기준 개발에 관한 연구)

  • Choi, Kyu-Chool
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.218-228
    • /
    • 2009
  • The basic law about disaster and safety management and the fire fighting law state that the central government and the local governments are responsible for protecting the life and assets of the people. The well-fare developed nations have developed and are implementing diverse safety programs with making safe cities as their prime objective. Our nation has not yet practiced such actions. However, it is in demand to evaluate what safety policies are practiced by local governments for the people and to inform the people of those. Therefore, this research developed and suggests the assessment criteria and the assessment method to evaluate the safety level of a city by assessing the safety of buildings and facilities.

  • PDF

The Applicability Analysis of Life Safety Codes for High Fire Risk Building Applications (화재 위험성을 중심으로 한 건축물 용도별 한국형인명안전기준의 적용성 검토에 관한 연구)

  • Koo, In-hyuk;Kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.103-104
    • /
    • 2022
  • In Korea, the occurrence and risk of similar fires are high, so setting up fire prevention measures through fire case investigation is considered the most basic measure in securing human safety. In particular, calculation of evacuation capacity in evacuation safety design of buildings is the most important factor that directly affects evacuation safety performance. However domestic standards is not consider about occupant characteristics. also the case of domestic, it has the problem that the law is partially applied when the fire safety design of buildings. Therefore, the purpose of this study is to study the current status and related regulations of the life safety code for the application of high fire risk buildings, and to analyze the difference in evacuation time through Case Study.

  • PDF

A Study on the Effective Method of Fire Extinguisher Maintenance In the Underground Parking Lot of the Apartment (아파트 지하주차장 소화기의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2016
  • The definition of an apartment is a building more than 5 stories high and which is the standard law. Currently, the number of apartments is increasing much faster than detached houses. Owning an apartment is a normal trend these days. However, the increasing number of apartments has been increasing the number of apartment fires which also has been making social problems. Therefore, this study was conducted for the fire extinguisher among other fire facilities because it is important for initial fire suppression. The research subject is on the fire extinguisher that is in the underground parking lot of 40 apartment complexes which are more than 10 stories. Survey and analysis were conducted for 80 fire extinguishers. There are two fire extinguishers for each apartment. The result of this study is that all installed fire extinguishers are ABC dry chemical type, 92% of them is 3.3kg and that meet the legal height(less than 1.5m). However, the condition such as appearance, inspection, manufactured year, appearance of signs, material of signs, size of signs, etc. was insufficiency. So improvement of law and system that are fire facility construction, maintenance implementation and additional designation of type approval about sign will be needed in my opinion.

A Study on Fire Safety Management of Social Welfare Facilities (사회복지시설의 화재안전관리에 관한 연구)

  • Choi, Kyu-Chool
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • The fire safety of social welfare facilities increasing at high speed with coming-up of an aging society have been on the rise as a very important social problems. This research paper has analyzed the fire safety laws and standards about the social welfare facilities as a lesson elderly nursing home's fire that occurred in recent years. This research worker have conducted the questionnaire survey including research of the true actual through the fire protection engineers, the professors, the fire facilities managers and the users. This study has proposed the installing of suitable fire protection systems through the law revision, normal maintenance of the facilities, the safety management plan through evaluation about fire protective management and related facilities by the methods of the fire safety management.

A Study on Fire Hazard Analysis and Smoke Flowing for the Semiconductor Manufacturing Process (반도체 제조공정의 연기유동에 관한 연구)

  • Han, Soo-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.197-211
    • /
    • 2007
  • The power of semiconductor, Korea is continuously constructing semiconductor production line for keeping a front-runner status. however, studies and data about potential risks in semiconductor factory are still short. If fire does not initially suppressed, the fire causes a great damage. To decrease fire risk factors, in addition to fire fighting safety equipment, more important thing is how to design and construct fire protection system. The current fire protection codes about semiconductor factory come under functional law, and this law is short of consideration about particularity of factory. The existing prescriptive fire codes depending on experience compose without evident engineering verifications, thus equipments which is created by the current prescriptive fire code may bring about a variety of problems. For example, the design under the current regulation can not cope with the excessive investments, low efficiencies, and the diversifying construction designs and be applied to the quick changes of new technologies. Ergo, an optimal design for fire protection is to equip fire protection arrangements with condition and environment of production field. Manufacturing factory of semiconductors is a windowless airtight space. And for cleanliness, there exists strong flow of cooperation. Therefore, there is a need for fire safety design that meets the characteristic of a clean room. Accordingly, we are to derive smoke flow according to cooperation process within a clean room and construction plan of an optimal sensor system. In this study, in order to confirm the performance of proposed smoke-exhaust equipment and suggest efficient smoke exhaust device when there is a fire of 1MW of methane in the clean room of company H, we have implemented fire simulation using fluid dynamics computation.