• Title/Summary/Keyword: Fire risk evaluation

Search Result 152, Processing Time 0.023 seconds

A Study on Total Fire Risk Assessment of Wallpapers (벽지의 종합적 화재 위험성 평가에 관한 연구)

  • 박미라;김광일;김태구
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.33-39
    • /
    • 2003
  • The purpose of this study is to evaluate flame retardant performance, thermal stability and toxicity of combustion gases for some commercial wallpapers. ID evaluate flame retardant performance 45 degree combustion experiment method was used and thermal stability was evaluated using DSC and TGA apparatus (OSC-50/Shimadzu, TGA2050/TA Instruments Inc) . Concentrations of CO, $CO_2$, HCN and HCI were measured with (GASTEC/Japan, MSA400 Gas Monitor/Infitron Inc) and toxicity indices using NIST N-Gas Model were applied to evaluate the toxicity of combustion gases. The evaluation produced the following results : First, paper cork and PVC wallpaper treated with flame retardants were found to be suitable for flame retardant performance standards. Second, paper, cork and PVC wallpaper non-treated with flame retardants were shown to be relatively more hazardous because they had greater calorific values and a faster decomposition time than the flame retardant treated wallpapers. Third, the toxicity indices of non-treated wallpapers were found to be higher than those of treated wallpapers, and the toxicity index of PVC wallpapers was higher than those of paper and cork wallpapers.

Analysis of Work Postures of Fire Fighters for Prevention of Musculoskeletal Disorders (소방대원들의 근골격계질환 예방을 위한 작업 자세 분석)

  • Roh, Hyo-Lyun;Son, Sung-Min;Oh, Hyun-Soo;Chang, Seong-Rok;Kim, Yong-Jae
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.71-78
    • /
    • 2011
  • The aim of study was to reduce risk factors of musculoskeletal disorders, and prevent it according to evaluation and analysis of its symptoms survey, and work postures which doing much frequently. This study was conducted by 64 firefighters. It was surveyed physical burden levels, distribution of musculoskeletal symptoms, and analized work postures by using ergonomics tools, such as Rapid Entire Body Assesment(REBA), Rapid Upper Lim Assessment(RULA), NIOSH Lifting Equation(NLE). Physical burden levels, and distribution of musculoskeletal symptoms were surveyed according to frequency analysis, and the analysis of above tools were presented figures and scores. The all the results of REBA were that risk level was "High", action level was "Need soon" and the results of RULA were "The results are required detailed survey and immediate improvement" at Require rescue person handling, fire hose, hybraulic rescue equipment, universal axe work postures. The occurrence possibility of musculoskeletal disorders of fire fighters is quite high due to instability postures, excessive physical work and so on. Thus, making various efforts to prevent disorders, and improving working environment is necessary continuously.

Study on the Establishment of a Safety Allowance Level of Disastrous and Hazardous Facilities in Large Cities (대도시 위해.위험시설에 대한 안전도 수용기준 정립에 관한 연구)

  • 고재선;윤명오
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.84-92
    • /
    • 2001
  • In today's world, rise in the establishment of social infrastructure resulting from population saturation in large cities has led to more extensive and frequent use of chemical materials on facilities. A result, unexpected and serious accidents, hazards, contingencies and disasters are more prevalent than ever. Such phenomenon calls for more devoted and concerted efforts towards finding ways to reduce the safety hazards that are seen to take place more often than before with the increase in the number of facilities that are prone to bring disaster and hazard coupled with the conventional safety problems that continue to exist even today. In developed countries, such challenge is addressed by various appropriate countermeasures drawn up by local professional committees on industrial facilities, whose members conduct offsite and onsite evaluation un the potential industrial disasters and its seriousness and provide their advice thereof. Against this backdrop, this study aims at identifying a comprehensive safety allowance level (safety acceptable level) when imposing limitation on the development of conventional or new facilities, for the fur pose of establishing a safety allowance level of disastrous and dangerous facilities in Korea. This is done by assessing and applying the level of danger each individual is exposed to in a randomly selected region (disastrous and dangerous areas in Seoul) based on probability of quantitative hazards, as well as simulation and calculation methods which include: i) social disaster evaluation method applying Quantified Risk Assessment of Health & Safety Executive of UK and Matrix of Risk of Evaluated Sources of Hazard; ii) Fault Tree or Event Tree Analysis and etc.

  • PDF

Risk Assessment of Smoke Generated During Combustion for Some Wood (일부 목재의 연소 시 발생되는 연기의 위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.33 no.4
    • /
    • pp.373-380
    • /
    • 2022
  • In this study, Chung's equations 1, 2, and 3 were extended to standardize smoke safety rating evaluation in case of fire, and Chung's equations-V, smoke performance index-V, and smoke growth index-V were calculated. Five types of wood were selected and their smoke indices were measured using the cone calorimeter method according to ISO 5660-1. The smoke risk was graded by the smoke risk index-VI according to Chung's equation-VI. Smoke risk index-VI increased in the order of PMMA (1) ≈ maple (1.01) < ash (1.57) < needle fir (4.98) < paulownia (46.15) < western red cedar (106.26). It was predicted that maple and ash had the lowest smoke risk, and paulownia and western red cedar had the highest. The five samples' CO mean production rate (COPmean) was 0.0009~0.0024 g/s, indicating that these woods were incompletely burned than the polymethyl methacrylate (PMMA) reference material. Regarding the smoke properties of the chosen woods, the smoke performance index-V (SPI-V) increased as the bulk density increased, and the smoke risk index-VI (SRI-VI) decreased.

A Study on Structural Analysis for Stability Evaluation According to Design Parameters of a Fire Ladder Vehicle (소방 고가사다리차의 설계 변수에 따른 안정성 평가를 위한 구조해석 연구)

  • Jung, Hoon;Kim, Cheol-Jung;Kim, Hong-Gun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.8
    • /
    • pp.64-72
    • /
    • 2020
  • In this study, a stability analysis was conducted through finite element analysis (FEA) of a simplified model of a fire ladder truck by changing the ascending angle, turning angle, and boundary conditions between the outrigger and the ground. The results of the analysis showed that decreasing the angle of the ladder car increases the moment due to the ladder weight, decreasing the safety factor despite being under the same load conditions. In the case of a rotating radius, the stability was found to vary depending on the boundary conditions. A comparative analysis in the future with these results and the experimental values from the actual fire ladder truck may determine the most appropriate boundary conditions based on the analysis program. It is expected to predict the risk of damage and rollover by assessing the stability of aerial ladder vehicles under different conditions.

A Study on the Effective Method to Producing Data for The ROKA Live Fire Training Range Safety (한국군 실 사격 훈련간 효율적인 안전지대 데이터 구축 방안 연구)

  • Lee, June-Sik;Choi, Bong-Wan;Oh, Hyun-Seung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.3
    • /
    • pp.64-77
    • /
    • 2015
  • An effective method for produce munitions effectiveness data is to calculate weapon effectiveness indices in the US military's Joint Munitions Effectiveness Manuals (JMEM) and take advantage of the damage evaluation model (GFSM) and weapon Effectiveness Evaluation Model (Matrix Evaluator). However, a study about the Range Safety that can be applied in the live firing exercises is very insufficient in the case of ROK military. The Range Safety program is an element of the US Army Safety Program, and is the program responsible for developing policies and guidance to ensure the safe operation of live-fire ranges. The methodology of Weapon Danger Zone (WDZ) program is based on a combination of weapon modeling/simulation data and actual impact data. Also, each WDZ incorporates a probability distribution function which provides the information necessary to perform a quantitative risk assessment to evaluate the relative risk of an identified profile. A study of method to establish for K-Range Safety data is to develop manuals (pamphlet) will be a standard to ensure the effective and safe fire training at the ROK military education and training and environmental conditions. For example, WDZs are generated with the WDZ tool as part of the RMTK (Range Managers Tool Kit) package. The WDZ tool is a Geographic Information System-based application that is available to operational planners and range safety manager of Army and Marine Corps in both desktop and web-based versions. K-Range Safety Program based on US data is reflected in the Korean terrain by operating environments and training doctrine etc, and the range safety data are made. Thus, verification process on modified variables data is required. K-Range Safety rather than being produced by a single program, is an package safety activities and measures through weapon danger zone tool, SRP (The Sustainable Range Program), manuals, doctrine, terrain, climate, military defence M&S, weapon system development/operational test evaluation and analysis to continuously improving range safety zone. Distribution of this K-range safety pamphlet is available to Army users in electronic media only and is intended for the standing army and army reserve. Also publication and distribution to authorized users for marine corps commands are indicated in the table of allowances for publications. Therefore, this study proposes an efficient K-Range Safety Manual producing to calculate the danger zones that can be applied to the ROK military's live fire training by introducing of US Army weapons danger zone program and Range Safety Manual

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

A Study on the Safety Improvement by CFD Analysis for Packaged Type Hydrogen Refueling System (CFD 툴을 활용한 패키지형 수소충전시스템의 안전성 향상 연구)

  • HWANG, SOON-IL;KANG, SEUNG-KYU;HUH, YUN-SIL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.3
    • /
    • pp.243-250
    • /
    • 2019
  • In this study, to ensure the safety of the packaged hydrogen refueling system, the improvement plan was derived by using 3-dimensional CFD program (FLACS). We also confirmed the effectiveness of risk reduction and the suitability of safety standard. By ventilation performance evaluation according to the position of the vent, it demonstrated that the vent should be installed at the ceiling to safely ventilate without stagnation of the leaked gas. In case of ventilation system according to KGS standard, risk situation could be resolved after about 5 minutes in the worst leaked condition. The result showed that jet fire and explosion inside the packaged system could affect the surrounding facilities. This proves that the standard for installing flame detectors, emergency shut down system and protection wall is appropriate.

A Systematic Review and Meta-Analysis of Fire Needling Treatment for Knee Osteoarthritis: Focused on Comparative Studies with Manual Acupuncture Treatment during Recent Five Years (퇴행성 슬관절염의 화침 치료에 대한 체계적 문헌 고찰 및 메타분석: 최근 5년간의 호침 치료 비교 연구를 중심으로)

  • Ko, Hong-Je;Yoo, Jae-Hee;Shin, Jeong-Cheol
    • Korean Journal of Acupuncture
    • /
    • v.36 no.2
    • /
    • pp.104-114
    • /
    • 2019
  • Objectives : The purpose of this study is to review the effectiveness of fire needling treatment for knee osteoarthritis in comparison with manual acupuncture treatment. Methods : Through four foreign online databases (PubMed, Cochrane library, EMBASE, and CNKI) and five domestic online databases (NDSL, RISS, KISS, OASIS, and KTKP), we searched for clinical studies that performed fire needling treatment for knee osteoarthritis until May 10, 2019. Only randomized controlled trials were selected and we assessed the risk of bias according to the Cochrane RoB criteria. This review examined the selected studies into first author, publication year, sample size, outcome measurements, results, acupoints, treatment time & period and so on. Results : A total of 7 RCTs were selected in this review and all were conducted in China. Treatment period of more than 4 weeks and treatment visits of 10 to 20 times were the most common. EX-LE4 and ST35 (=EX-LE5) acupoints were most frequently selected in treatment. Among the evaluation indexes, a total efficacy rate was used the most. Most of fire needling groups showed more significant results compared with the manual acupuncture groups statistically. Conclusions : All studies showed that fire needling treatments for knee osteoarthritis were more effective than manual acupuncture treatments statistically. Therefore, the results of this study could be utilized as a preliminary data for another clinical research on fire needling treatment for knee osteoarthritis. However, further well-designed randomized controlled trials will be needed to develop sufficient evidence about the effectiveness and safety of fire needling treatment for knee osteoarthritis in the future.

Case Study on the Analysis of Disaster Vulnerabilities (Focused on the Fire & Explosion in the N-Industrial Complex) (재난 취약성 분석에 관한 사례연구(N공단의 화재·폭발을 중심으로))

  • Ha, Kag Cheon
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.94-100
    • /
    • 2021
  • In general, the industrial complex is a place where factories of various industries are concentrated. It is only as efficient as it is designed. However, the risks vary as there are various industries. These features are also associated with various types of disasters. The dangers of natural disasters such as a typhoon, flood, and earthquake, as well as fire and explosions, are also latent. Many of these risks can make stable production and business activities difficult, resulting in massive direct and indirect damage. In particular, decades after its establishment, the vulnerabilities increase even more as aging and small businesses are considered. In this sense, it is significant to assess the vulnerability of the industrial complex. Thus analysing fire and explosion hazards as stage 1 of the vulnerability evaluation for the major potential disasters for the industrial complex. First, fire vulnerabilities were analyzed quantitatively. It is displayed in blocks for each company. The assessment block status and the fire vulnerability rating status were conducted by applying the five-step criteria. Level A is the highest potential risk step and E is the lowest step. Level A was 11.8% in 20 blocks, level B was 22.5% in 38 blocks, level C was 25.4% in 43 blocks, level D was 26.0% in 44 blocks, and level E was 14.2% in 24 blocks. Levels A and B with high fire vulnerabilities were analyzed at 34.3%. Secondly, the vulnerability for an explosion was quantitatively analyzed. Explosive vulnerabilities were analyzed at 4.7% for level A with 8 blocks, 3.0% for level B with 5, 1.8% for level C with 3, 4.7% for level D with 8, and 85.8% for level E with 145. Levels A and B, which are highly vulnerable to explosions, were 7.7 %. Thirdly, the overall vulnerability can be assessed by adding disaster vulnerabilities to make future assessments. Moreover, it can also assist in efficient safety and disaster management by visually mapping quantified data. This will also be used for the integrated control center of the N-Industrial Complex, which is currently being installed.