• Title/Summary/Keyword: Fire rating

Search Result 102, Processing Time 0.023 seconds

저압용 소형 관형퓨즈의 용단 특성에 관한 실험적 연구 (An Experimental Study on Melting Characteristics of Low-voltage Miniature Cartridge Fuse)

  • 지홍근;김진표;송재용;최영우;박찬성;박남규;길경석
    • 한국안전학회지
    • /
    • 제28권5호
    • /
    • pp.15-20
    • /
    • 2013
  • This paper dealt with melting characteristics of low-voltage miniature cartridge fuse used for 220 V electronic equipment. The experimental sample is low-voltage miniature cartridge fuse with rating of 250 V(3A) and size of $5{\times}20$ mm. In order to evaluate melting and scattering characteristics of the fuse, we applied to 8/20 ${\mu}s$ surge current, overload current and external thermal stress such as flame of fire. From the experimental results, the fuse element was melted and scattered by applied surge current(above 0.79 kA) and overload current(above 4.5 A). It was also attached to the inner surface of the fuse tube. The fuse element was attached as a thin film on inner surface of fuse tube when large surge current was applied. It was confirmed, however, the fuse element was not changed by external thermal stress such as flame and hot-air.

청소년 지위비행의 인과적 경로 (Causal Pathway Analysis of Adolescence Status Delinquency)

  • 조영숙;신유선
    • 한국간호교육학회지
    • /
    • 제7권2호
    • /
    • pp.379-390
    • /
    • 2001
  • The purpose of this study was to examine the actual condition of the adolescent status delinquency and to predict that family environments, the mother's rear attitudes and personal factors influence on the adolescent status delinquency among high school students in Busan(N=404). Under these purposes of the study, the preliminary study was performed to divided the criminal delinquency from the status delinquency, and on the basis of the result of the preliminary study, the analysis of causal pathway were performed. The data were surveyed using paper and pencil self-rating. Descriptive statistics and pathway analyses were conducted to answer research objectives. The result of this study was as follows. First, the status delinquency and the criminal delinquency are different dimensions with each other independently. Second, Contents of the status delinquencies were Drinking, Smoking, Cheating examination, Stopping out, Reckless running, Gang fighting, Reading lewdness and Watching lewd video, Sexual intercourse with the other gender, etc., The criminal delinquencies were Robbing of bicycle or auto-bicycle, Taking nalcotic drug, Robbing money of drunkard and women, Rape, Setting on fire, etc. Third, The factors of structural environments of the family and the factors of mother's rear attitude influenced on the status delinquency via adolescence's compulsivity. that is to say, if the mother's rear attitude is affective, it restrains the impulsivity of adolescence causing to the restraint of the status delinquency.

  • PDF

경량기포콘크리트(ALC) 패널을 건축물 외장 커튼월에 적용을 위한 도료의 기초적 연구 (Applications and Analysis of Exterior Paints for the Curtain Wall Panel System based on the Autoclaved Lightweight Concrete(ALC))

  • 이용수;라현주
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권3호
    • /
    • pp.59-66
    • /
    • 2012
  • Autoclaved Lightweight Concrete(ALC) features such as a high performance insulation, the fire resistance, the advantage of easy handing construction, and lightweight panels applied the curtain wall system. ALC materials are certified as non-toxic environmental and eco-friendly productions. But ALC external panels mixed with blast furnace slag pounder and silica fume have to be coated with a stucco compound or plaster because of resisting the ambient environment. This study is that mixing tests to evaluate a performance analysis of exterior paints to be make-up pigments(organic or inorganic) coated with panel surface. Testing compared by KS F 2476; flow test, KS F 2426; compression strength test, KS F 2762; bond strength test. In results, the case of the inorganic binder, ratio of alumina cement : anhydrite is 90:10 to 80:20 at the highest level of intensity. In the case of the organic binder, adhesive strength rating at surface of ALC, the pullout strength is below 0.5 $N/mm^2$ but the normal concrete is over 2.0$N/mm^2$. A contents ratio of EVA resin is more than 3% and then bond strength is effectively.

산악기상자료와 목재평형함수율에 기반한 산림연료습도 추정식 개발 (Modeling and mapping fuel moisture content using equilibrium moisture content computed from weather data of the automatic mountain meteorology observation system (AMOS))

  • 이훈택;원명수;윤석희;장근창
    • 한국지리정보학회지
    • /
    • 제22권3호
    • /
    • pp.21-36
    • /
    • 2019
  • 본 연구는 산불 위험 예측의 주요 인자인 10시간 사연료습도(10-h FMC)를 산악기상관측망 기상자료로 추정하는 방법을 마련하기 위해 수행되었다. 안성(도심지)과 홍릉 두 지점(숲 속, 숲 밖)의 자동기상관측소에서 기상인자와 10-h FMC를 측정하고 이를 이용해 10-h FMC 추정식을 도출했다. 도출한 추정식을 이용해 지난 6년간(2013~2018년) 산불발생 다발일의 10-h FMC를 분석하고 전국 10-h FMC 지도를 제작했다. 기상인자(기온, 풍속, 목재평형함수율, 강우량)와 10-h FMC의 회귀분석 결과 목재평형함수율이 가장 효율적으로 10-h FMC를 설명했음을 확인했다. 목재평형함수율을 이용해 도출한 10-h FMC 추정식은 모형 적합과 검증과정 모두에서 높은 적합도를 보였다. 각 연구지의 추정식을 서로 다른 연구지에 적용하면 모형의 적합도가 같은 연구지에서 만든 식을 적용했을 때보다 줄어들었지만 여전히 만족할 만한 결과를 보였다. 본 연구의 회귀식은 10-h FMC와 목재평형함수율 사이 강우 후 건조반응 차이와 식생 유무가 10-h FMC에 미치는 영향을 반영하지 못해 적합도가 줄어든 것으로 나타났다. 마지막으로 도출한 추정식을 사용한 공간분석을 통해 지난 6년간 산불발생 다발일의 산불 중 70% 이상이 10.5% 이하의 10-h FMC 조건에서 발생했음을 확인했다. 본 연구 결과는 산악기상관측망과 연계하여 전국 산지의 10-h FMC를 추정하는 데 사용할 수 있다. 10-h FMC는 산불 위험 예측 기초 연구 자료로 활용되어 재해 관련 국가 정책 결정에 기여할 것으로 판단된다.

섬유강화재 함유율에 따른 FRTP의 기계적 특성 및 연소특성에 관한 연구 (A Study on the Mechanical and Combustion Characteristics According to Fiber Reinforcements Weight Fraction of FRTP)

  • 김경진;엄상용;김기환
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.21-28
    • /
    • 2019
  • 본 연구에서는 섬유강화 열가소성 플라스틱 복합재료(Fiber Reinforced thermo plastics, FRTP)의 기계적 특성 및 화재 위험성 예측을 위한 연소특성을 평가하였다. 폴리카보네이트와 나일론에 섬유강화재로 유리섬유와 탄소섬유를 각각 0~40 wt% 혼합하여 특성변화를 실험한 결과, 섬유강화재의 함유율이 증가할수록 비강도와 열변형 온도가 증가하였고 난연성은 유리섬유 함유율이 30 wt% 이상인 경우 V-0 등급을 보였다. 연소특성의 경우 섬유강화재의 함유율이 증가함에 따라 착화시간도 비례하여 증가하였으며, 최대 열방출율은 섬유강화재를 40 wt% 함유 시 함유하지 않았을 때보다 폴리카보네이트는 약 51%, 나일론은 약 24% 수준으로 낮아졌다. CO 발생율은 일정시간까지 감소하다가 증가하는 경향을 보이며, 이는 시간이 지남에 따라 불완전연소에 의한 것으로 판단된다. CO2 발생율은 열방출율과 매우 유사한 경향을 보이며, 최대 CO2 발생율은 섬유강화재를 40 wt% 함유 시 함유하지 않았을 때보다 폴리카보네이트는 약 50%, 나일론은 약 28% 수준으로 낮아졌다.

Ecological Green Roofs in Germany

  • Kohler, Manfred
    • 한국환경복원기술학회지
    • /
    • 제7권4호
    • /
    • pp.8-16
    • /
    • 2004
  • The industrialization of central Europe more than 100 ago marked the beginning of densely concentrated buildings in quickly growing cities. A cheap type of roofing material of that time was tar. But it was dangerous because it was high inflammable. Then some roofer had a splendid idea. They used sandy material as a final layer atop the impermeable tar layer. These roofs were much more fire resistant than the typical roofs. In this sandy layer some plant species began to grow spontaneously. This was the beginning of the green roof history of modern Europe. A number of these green roofs survived both world wars. In the early 80's in Berlin alone, 50 such buildings existed and they continued to be waterproof until the present day. Since the 1992 Earth Summit of 1992 in Rio de Janeiro(http://www.johannesburgsummit.org/html/basic_info/unced.html) the term "sustainable development" became of central interest of urban designers. In city regions green roofs had become synonymous with this term. With a small investment, long-lasting roofs can be created. Further back in history, more exciting examples of green roofs can be found. The hanging gardens of antiquity are well-known. There are also green roofs built as insulation against cold and heat all over the world. For over 20 years, roof greening in central Europe has been closely examined for various reasons. Roof greening touches several different disciplines. Of primary interest is the durability of the roofs. But ecologists are also interested in green roofs, for instance in biodiversity research. The beneficial effect of greening on water proofing was also proven. For some time, the issue of fire protection was investigated. According to tests, green roofs received a harsh careful rating. Their fire protective property is considered similar to that of tile roofs. Another recent impulse for the green roof movement in Germany has come from the evident improvement of storm water retention and the reduced burden on the sewer system. The question of whether and how much energy green roofs can save has become an urgent question. The state of the research and also various open questions from a central European point of view will be discussed in the context of international collaboration. Apart from academic considerations, those who involve themselves in this issue take a predominantly positive view of the numerous existing green roofs in Germany. In some cities, green roofs are the typical construction technique for new buildings. A few outstanding examples will conclude this review. In Germany, about 20 companies, some of which operate internationally, specialize in green roof consulting. Learning from each other in an open-ended way with respect to different construction techniques and applications in various climatic regions can only be accomplished through such international collaboration as is taking place here.

일부 목재의 연소 시 발생되는 연기의 위험성 평가 (Risk Assessment of Smoke Generated During Combustion for Some Wood)

  • 정영진;진의
    • 공업화학
    • /
    • 제33권4호
    • /
    • pp.373-380
    • /
    • 2022
  • 본 연구에서는 화재 시 연기안전 등급 평가를 표준화하기 위해 Chung's equations 1, 2와 3을 확장하여 Chung's equations-V인 연기성능지수-V와 연기성장지수-V를 산정하였다. 5종류의 목재를 선별하여 ISO 5660-1의 규격에 의한 콘칼로리미터(cone calorimeter)법으로 연기지수들을 측정하였다. Chung's equation-VI에 따라 연기위험성지수-VI에 의한 연기위험성을 등급화 하였다. 연기위험성지수-VI는 PMMA(1) ≈ 단풍나무(1.01) < 물푸레나무(1.57) < 전나무(4.98) < 오동나무(46.15) < 적삼목(106.26)의 순서로 증가하였다. 단풍나무, 물푸레나무의 연기위험성이 가장 낮고, 오동나무, 적삼목이 가장 높은 것으로 예측되었다. 시험편 5종의 일산화탄소 평균생성속도는 0.0009~0.0024 g/s으로 나타났으며, 이들 목재는 기준 물질인 polymethyl methacrylate보다 불완전연소 물질임을 나타내었다. 선정된 목재들의 연기특성은 체적밀도가 높을수록 연기성능지수-V (SPI-V)이 증가하였고, 연기위험성지수-VI (SRI-VI)가 감소하였다.

산불 방지를 위한 산악기상관측시스템 구축방안 (A Study on Establishment of the Optimum Mountain Meteorological Observation Network System for Forest Fire Prevention)

  • 이시영;정일웅;김상국
    • 한국농림기상학회지
    • /
    • 제8권1호
    • /
    • pp.36-44
    • /
    • 2006
  • 본 연구에서는 강원 영동 및 경북 동부지역의 산악기상관측시스템 구축을 위한 AWS 위치선정, 네트워크 구성(관측시스템, 통신시스템, 자료처리시스템)과 특히, 산불방지를 위해 산림청과 지방자치단체가 기 설치한 산불무인감시카메라, 무선중계탑의 산악기상관측망과의 연계 구축방안과 산악기상관측망의 관리방안을 제시하였으며, 본 연구를 통해 얻어진 사항은 다음과 같다. 산지가 많은 강원도에서는 산악지형에 따른 악기상이 자주 발생하여 강원지방기상청에서는 관측망을 유지관리 하는데 고초를 겪고 있으며 강풍, 뇌전현상 등으로 장비피해를 많이 입어, 보다 피해를 최소화할 수 있는 여러 가지 방안들을 강구하여 왔다 따라서 산악지형에 관측망을 구성하기 위해서는 장비의 견고성을 최우선적으로 반영해야 한다. 전원시설은 가능한 태양전원을 권장하지만 일조량이 적은 깊은 계곡과 같은 지역에 설치가 이루어질 경우 상용전원을 사용할 수밖에 없으며 대부분 산악에서의 전원시설은 열악하여 전원 백업시설 설치를 강구해야 한다. 전원 백업시설의 효율성을 유지하기 위해서는 소비전력이 적은 시스템을 선택하여 관측자료의 손실을 최대한 방지해야만 한다. 또한 태양전원을 이용할 경우 충전과 소모량을 사전에 면밀히 검토해야 한다. 산악은 뇌전현상이 근접하고 잦기 때문에 뇌전으로부터 장비 보호시설 설치를 강구하기 위해 피뢰접지 및 장비접지 시설에 투자를 아껴서도 안 될 것이다. 뇌전으로부터의 장비 보호시설을 강구하는 것도 중요 하지만 써지에 강한 제품을 채택하는 것이 보다 중요하다고 하겠다. 자료수집에 있어서는 전원 및 통신환경을 감안하여야 하며 전체 통신망을 단일화하는 것도 간결하지만 단일 통신망만을 채택할 경우에는 한계성이 있으므로, 다양한 통신망을 이용하는 것이 자료수집의 한계를 극복할 수 있는 방법이다. 따라서 수집 통신망을 통한 기상 관측 자료를 인근 1차 수집기관을 거쳐 최종 메인 수집장치로 내부망을 따라 수집하는 것이 최선의 망 운영방법이다. 자동관측시스템(AWS) 설치 시 기존의 무인감시카메라와 무선중계탑을 최대한 활용하되 무인감시카메라 설치위치$(70\siml,245m)$와 무선중계탑의 설치위치 $(299\sim1,573m)$가 산불위험지역에 포함되어 있는지의 면밀한 검토가 요구된다. 산불 등 각종 산림재난 방지와 관련한 정보를 얻을 수 있는 자동기상관측시스템(AWS)의 설치 위치는 산불발생확률모형에서 산정된 위험지역 내에 설치하는 것이 산불발생 위험지역을 판정하는데 매우 효과적일 것으로 판단된다. 기상청과 지자체가 보유하고 있는 기상관측 장비들은 대부분 도시를 중심으로 설치 운영되고 있어 산림 또는 산악에 설치된 기상관측 장비의 수는 적은 편이다. 따라서 산림과 산악에 기상관측 장비의 보강은 필수적이다. 관측망 구성은 기상청의 관측 표준(안)을 준수하며, 설치 지점의 특성에 따라 가장 경제적인 방법을 선택하는 것이 바람직하며, 특히 장비구매 설치 시 다양한 종류의 제품을 선택하는 것은 차후 장비 관리에 어려움을 겪을 소지가 있어 가능한 우수한 제품을 선택하되 동일 제품 사용을 권장한다. 따라서 위의 망구축이 이루어져 현재 기상청이 설치 운영하고 있는 측정 장비에 의해 취득한 기상자료를 공동 활용하여 표출하면 더욱 상세한 자료의 획득과 활용이 기대되어 진다. 또한, 금번 논문에서는 산불위험지역의 격자점(15km)내에 최소한 1대의 AWS 설치방안을 제시하였지만, 금후에는 15km내에서도 능선, 계곡 등 구체적인 위치확정을 위한 선행연구가 실시되어야할 것으로 판단된다.

화학물질 관리 연구-1. 산업안전보건법상 관리 화학물질의 특성과 노출기준 비교 (Study on the Chemical Management - 1. Chemical Characteristics and Occupational Exposure Limits under Occupational Safety and Health Act of Korea)

  • 박지훈;함승헌;김선주;이권섭;하권철;박동욱;윤충식
    • 한국산업보건학회지
    • /
    • 제25권1호
    • /
    • pp.45-57
    • /
    • 2015
  • Objectives: This study aims to compare the physicochemical characteristics, toxicological data with Occupational Exposure Limits (OELs) of chemicals under the Occupational Safety and Health Act(OSHA) regulated by the Ministry of Employment and Labor of Korea. Methods: Information on chemicals which have OELs on physicochemical characteristics and toxicological data was collected using Material Safety Data Sheet(MSDS) from Korea Occupational Safety and Health Agency(KOSHA) and the Korea Information System for Chemical Safety Management(KISChem) in 2014. Statistical analyses including correlation and simple regression were performed to compare the OELs with chemical characteristics including molecular weight, boiling point, odor threshold, vapor pressure, vapor density, solubility and octanol-water partition coefficient(OWPC) and toxicological data such as median lethal dose($LD_{50}$) and median lethal concentration($LC_{50}$). Results: A total of 656 chemicals have OELs under OSHA in Korea. The numbers of chemicals which have eight-hour time weighted average(TWA) and short term exposure limits(STEL) are 618 and 190, respectively. TWA was significantly correlated with boiling point and STEL was only correlated with vapor pressure among physicochemical characteristics. Solubility and OWPC between "skin" and "no skin" substances which indicate skin penetration were not significantly different. Both $LD_{50}$ and $LC_{50}$ were correlated with TWA, while the $LC_{50}$ was not with STEL. As health indicators, health rating and Emergency Response Planning Guidelines(ERPG) rating as recommended by the National Fire Protection Association(NFPA) and American Industrial Hygiene Association(AIHA) were associated with OELs and reflect the chemical hazards. Conclusions: We found relationships between OEL and chemical information including physicochemical characteristics and toxicological data. The study has an important meaning for understanding present regulatory OELs.

기후환경 변화에 따른 전기재해 위험도 분석 (Analysis and Risk Prediction of Electrical Accidents Due to Climate Change)

  • 김완석;김영훈;김재혁;오훈
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.603-610
    • /
    • 2018
  • 본 산업의 발달 및 화석연료 사용 증가로 인하여 지구온난화 및 기후변화가 가속화되어 기존보다 강도 높은 자연재해가 빈번하게 발생하고 있다. 전기시설물은 옥외에 시설된 경우가 많아 자연재해에 큰 영향을 받아 전기설비 관련 사고가 증가하는 추세이다. 본 논문에서는 국내의 기후변화에 따른 전기화재, 감전사고 및 전기설비사고의 통계 현황을 분석하여 기후변화와 연계한 위험도를 제시한다. 또한, 다양한 지역 별(광역시) 기후조건(온도, 습도)과 연계한 전기재해 데이터 분석을 통하여 각 지역의 월별 전기화재 위험도 분석 모델을 제시하고, 저압, 고압 설비의 자연재해에 대한 사고 위험도를 분석한다. 이러한 지역별, 설비별 위험도 분석 모델을 통하여 기초적인 전기재해 예측 모델을 제시하였다. 따라서 제시한 분석 데이터를 활용하여 향후 각 지역 및 전기설비를 대상으로 전기재해 위험도 예측 맵을 웹사이트나 스마트폰 앱을 통하여 전기안전 서비스를 제안할 수 있으며, 기후변화의 따른 자연재해에 대한 전기사고를 미연에 방지하기 위한 내성기준이나 전기설비의 내구성을 증가시키기 위한 노력이 필요하다.