• Title/Summary/Keyword: Fire monitoring

Search Result 397, Processing Time 0.022 seconds

A study on CFRP based lightweight House deck structure design and configuration of Deck body connected IoT sensor data acquisition devices

  • Jaesang Cha;Chang-Jun Ahn;Quoc Cuong Nguyen;Yunsik Lim;Hyejeong Cho;Seung Youn Yang;Juphil Cho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.250-260
    • /
    • 2023
  • In this paper, we designed a IoT(Internet of Things) sensor block embedded lightweight house deck structures that can be implemented using Carbon Fiber Reinforced Polymer(CFRP). Deck-Sensor interconnection interface block via IoT connectivity Hub that can mount external environmental sensors such as fire sensors on the Deck body itself was also proposed. Additionally we described the configuration of devices for data acquisition and analysis based on IoT environmental detection sensors that can be commonly installed and used on these deck bodies. On the other hand, received sensing data based monitoring user interface(UI) also developed and used for sensing data analysis for remote monitoring center. Through the implementation of such IoT-based sensor data transmission and collection analysis devices and UI software, this paper confirmed the availability of CFRP based lightweight House deck structure and possibility of CFRP deck-based IoT sensor data networking and analysis functions.

Monitoring of Soil Bacterial Community and Some Inoculated Bacteria After Prescribed Fire in Microcosm

  • Song Hong-Gyu;Kim Ok-Sun;Yoo Jae-Jun;Jeon Sun-Ok;Hong Sun-Hee;Lee Dong-Hun;Ahn Tae-Seok
    • Journal of Microbiology
    • /
    • v.42 no.4
    • /
    • pp.285-291
    • /
    • 2004
  • The soil bacterial community and some inoculated bacteria were monitored to assess the microbial responses to prescribed fire in their microcosm. An acridine orange direct count of the bacteria in the unburned control soil were maintained at a relatively stable level $(2.0\~2.7\times10^9\;cells/g^{-1}{\cdot}soil)$ during the 180 day study period. The number of bacteria in the surface soil was decreased by fire, but was restored after 3 months. Inoculation of some bacteria increased the number of inoculated bacteria sev­eral times and these elevated levels lasted several months. The ratios of eubacteria detected by a flu­orescent in situ hybridization (FISH) method to direct bacterial count were in the range of $60\~80\%$ during the study period, with the exception of some lower values at the beginning, but there were no definite differences between the burned and unburned soils or the inoculated and uninoculated soils. In the unburned control soil, the ratios of $\alpha-,\beta-\;and\;\gamma-subgroups$ of the proteobacteria, Cytophaga-Fla­vobacterium and other eubacteria groups to that of the entire eubacteria were 13.7, 31.7, 17.1, 16.8 and $20.8\%,$ respectively, at time 0. The overall change on the patterns of the ratios of the 5 subgroups of eubacteria in the uninoculated burned and inoculated soils were similar to those of the unburned con­trol soil, with the exception of some minor variations during the initial period. The proportions of each group of eubacteria became similar in the different microcosms after 6 months, which may indicate the recovery of the original soil microbial community structure after fire or the inoculation of some bac­teria. The populations of Azotobacter vinelandii, Bacillus megaterium and Pseudomonas fluorescens, which had been inoculated to enhance the microbial activities, and monitored by FISH method, showed similar changes in the microcosms, and maintained high levels for several months.

Differences in Breeding Bird Communities by Post-fire Restoration Methods (산불 후 복원방법의 차이가 번식기 조류 군집에 미치는 영향)

  • Kim, Jin-Yong;Lee, Eun-Jae;Choi, Chang-Yong;Lee, Woo-Shin;Lim, Joo-Hoon
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.4
    • /
    • pp.508-515
    • /
    • 2015
  • Post-fire restoration can affect breeding bird communities and species compositions over a long-term period by determining pot-fire succession, and a long-term monitoring is therefore required to understand its impacts on forest birds. This study aimed to document the effects of post-fire restoration methods on breeding bird communities in three areas: unburned and two burned (nonintervention and intervention with clear-cut logging and planting) stands 13 years after the stand-replacing Samcheok forest fire at Mt. Geombong in Samcheok, South Korea. According to 108 point counts during the breeding season from April to June 2013, we found that the number of individuals, observed bird species, and species diversity index in intervention stands with clear-cut logging and planting were lower than that in nonintervention and unburned control stands. Foraging and nesting guild analysis also showed a lower abundance of foliage searchers, timber drillers, primary cavity nesters and secondary cavity nesters in intervention stands than in the other stands, while no significant difference was detected between the nonintervention and unburned stands. These results imply that an interventional restoration method may deter the recovery of avian breeding communities after forest fires, and also suggest that non-interventional restoration methods may be an effective way to benefit the species diversity and density of breeding bird communities.

A Study on the Reliability Improvement Plan on Electric Leakage & Ground Fault of Low-voltage Electrical Line (저압전로의 누전.지락에 대한 신뢰성향상 방안에 관한 연구)

  • Kang, Kyung-Won;Yoon, Myung-O;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.136-145
    • /
    • 2011
  • One of a large proportion among the causes of fire is electrical factors, and of fire by electric factors, the accident which accounted for over certain percentage is electric leakage and ground fault. In order to reduce the electric leakage and ground fault, the technical guidelines on the protection of ground fault in the low-voltage electrical line (KECG 1091-2011) was amended for reflecting recent international standard, IEC 60364-4-41, and new conservation methods, which improved the reliability by recovering the facility's all-time use operation and breakdown defect, was on the rise. Accordingly, in this paper, after grasping the fire's status for last 10 years and analyzing the risk of electrical fires, and as a way to improve the electric leakage and ground fault accident which accounted for more than certain percentage, the revision of KECG 1091-2011 will be reviewed. And then, after applying to the preventive conservation methods in order to enhance the protection reliability of electric leakage and ground fault detection, the problems at issue routine inspection scheme and durable years scheme in time-scheduled conservation method are listed, along with suggestion of the problem-solving scheme, and the leakage current integrated monitoring systems and digital electric leakage devices by status monitor conservation method will be proposed.

Change in the Concrete Strength of Forest Road Drainage Systems Caused by Forest Fires (산불로 인한 임도 배수시설의 콘크리트 강도 변화)

  • Ye Jun Choe;Jin-Seong Hwang;Young-In Hwang;Hyeon-Jun Jeon;Hyeong-Keun Kweon;Joon-Woo Lee
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.4
    • /
    • pp.451-458
    • /
    • 2023
  • As forest fires continue to increase in scale worldwide, the importance of forest roads in relation to forest fire prevention and suppression has become increasingly evident. To ensure effective functioning during a forest fire disaster, it is crucial to apply appropriate road planning and ensure roads' structural integrity. However, previous studies have predominantly focused on the impact of forest fires on firebreak efficacy and road placement, meaning that insufficient attention has been paid to ensuring the safety of these facilities. Therefore, this study sought to compare the strength of concrete facilities within areas damaged by forest fires over the past three years by using the rebound hammer test to identify signs of thermal degradation. The results revealed that concrete facilities damaged by forest fires exhibited significantly lower strength (15.6 MPa) when compared with undamaged facilities (18.0 MPa) (p<0.001), and this trend was consistent across all the target facilities. Consequently, it is recommended that safety assessment criteria for concrete forest road facilities be established to prevent secondary disasters following forest fire damage. Moreover, continuous monitoring and research involving indoor experiments are imperative in terms of enhancing the stability of forest road structures. It is expected that such research will lead to the development of more effective strategies for forest fire prevention and suppression.

A Study on the Application of RTLS Technology for the Automation of Spray-Applied Fire Resistive Covering Work (뿜칠내화피복 작업 자동화시스템을 위한 RTLS 기술 적용에 관한 연구)

  • Kim, Kyoon-Tai
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.5
    • /
    • pp.79-86
    • /
    • 2009
  • In a steel structure, spray-applied fire resistive materials are crucial in preventing structural strength from being weakened in the event of a fire. The quality control of such materials, however, is difficult for manual workers, who can frequently be in short supply. These skilled workers are also very likely to be exposed to environmental hazards. Problems with construction work such as this, which are specifically the difficulty of achieving quality control and the dangerous nature of the work itself, can be solved to some degree by the introduction of automated equipment. It is, however, very difficult to automate the work process, from operation to the selection of a location for the equipment, as the environment of a construction site has not yet been structured to accommodate automation. This is a fundamental study on the possibility of the automation of spray-applied fire resistive coating work. In this study, the linkability of the cutting-edge RTLS to an automation system is reviewed, and a scenario for the automation of spray-applied fire resistive coating work and system composition is presented. The system suggested in this study is still in a conceptual stage, and as such, there are many restrictions still to be resolved. Despite this fact, automation is expected to have good effectiveness in terms of preventing fire from spreading by maintaining a certain level of strength at a high temperature when a fire occurs, as it maintains the thickness of the fire-resistive coating at a specified level, and secures the integrity of the coating with the steel structure, thereby enhancing the fire-resistive performance. It also expected that if future research is conducted in this area in relation to a cutting-edge monitoring TRS, such as the ubiquitous sensor network (USN) and/or building information model (BIM), it will contribute to raising the level of construction automation in Korea, reducing costs through the systematic and efficient management of construction resources, shortening construction periods, and implementing more precise construction

Impact of the Smoke Aerosol from Russian Forest Fires on the Atmospheric Environment over Korea during May 2003 (2003년 5월 러시아지역에서 발생한 산불로 인한 스모크 에어로졸 플룸의 영향)

  • Lee, Kwon-Ho;Kim, Jeong-Eun;Kim, Young-Joon;Kim, Joon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.5
    • /
    • pp.603-613
    • /
    • 2004
  • Extensive forest fires occurred across the border in Russia. particularly east of Lake Baikal between the Amur and Lena rivers in May 2003. These forest fires released large amounts of particulates and gases into the atmosphere. resulting in adverse effects on regional air quality and the global radiation budget. Smoke pollution from the Russian fires near Lake Baikal was sometimes transported to Korea through Mongolia and eastern China. In this study ground based radiation (visible and UV-B) data measured during May 2003 at Seoul and Kwangju were analyzed to estimate smoke aerosol impacts on solar radiation. Surface criteria air pollutants ($PM_{10}$, CO, $O_3$) data were also obtained from National Institute of Environmental Research (NIER) during smoke aerosol event period (19 May~24 May 2003). Large Aerosol Optical Depth (AOD) 1.0~3.0 was observed during this period due to the influence of the long range transport of smoke aerosol plume from the Russian fires, resulting in short-wavelength direct aerosol radiative forcing of -90~ -200W/$m^2$. These smoke aerosol plume caused decrease in surface UV-B radiation up to 80% and increase in PM_(10) concentration up to 200${\mu}g/m^3$ exceeding the 24 hour ambient air quality standard.

Retrieval of Aerosol Microphysical Parameter by Inversion Algorithm using Multi-wavelength Raman Lidar Data (역행렬 알고리즘을 이용한 다파장 라만 라이다 데이터의 고도별 에어로졸 Microphysical Parameter 도출)

  • Noh, Young-Min;Kim, Young-Joon;Muller, Detlef
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.1
    • /
    • pp.97-109
    • /
    • 2007
  • Vertical distribution and optical properties of atmospheric aerosols above the Korean peninsula are quite important to estimate effects of aerosol on atmospheric environment and regional radiative forcing. For the first time in Korea, vertical microphysical properties of atmospheric aerosol obtained by inversion algorithm were analyzed based on optical data of multi-wavelength Raman lidar system developed by the Advanced Environmental Monitoring Research Center (ADEMRC), Gwangju Institute Science and Technology (GIST). Data collected on 14 June 2004 at Gwangju ($35.10^{\circ}N,\;126.53^{\circ}E$) and 27 May 2005 at Anmyeon island ($36.32^{\circ}N,\;126.19^{\circ}E$) were used as raw optical data for inversion algorithm. Siberian forest fire smoke and local originated haze were observed above and within the height of PBL, respectively on 14 June 2004 according to NOAA/Hysplit backstrajectory analysis. The inversion of lidar optical data resulted in particle effective radii around $0.31{\sim}0.33{\mu}m$, single scattering albedo between $0.964{\sim}0.977$ at 532 nm in PBL and effective radii of $0.27{\mu}m$ and single scattering albedo between $0.923{\sim}0.924$ above PBL. In the case on 27 May 2005, biomass burning from east China was a main source of aerosol plume. The inversion results of the data on 27 May 2005 were found to be particle effective radii between $0.23{\sim}0.24{\mu}m$, single scattering albedo around $0.924{\sim}0.929$ at 532 nm. Additionally, the inversion values were well matched with those of Sun/sky radiometer in measurement period.

Real-time measurement management system UI development linked the Water treatment facilities Broadband Convergence Network (수처리시설용 광대역 통합망 연계형 실시간 계측 관리 시스템 UI개발)

  • Yang, Seungyoun;Kim, Jintae;Oh, Hwanjin;Lee, Minwoo
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.83-86
    • /
    • 2015
  • In this paper, we propose a real-tim measurement management system UI development linked the Water treatment facilities broadband Convergence Network. The sensor and the image data received by the server develop a program to interact with Web through water treatment facilities broadband convergence network. So, Separately develop UI capable of independently operating. Building a web server for remote monitoring of the transmission sensor and the image data. And Monitoring and control is possible the sensor data and image data through the Web-based UI. We can grasp the current state such as measurement time, concentration and depth of interface through the proposed real-time measurement management system UI development liked the water treatment facilities broadband convergence network. So, we can check in whether the normal operation of water treatment facilities and whether the casualties such as fire and security. As well as real time to see the information at a glance due to UI development can be raal-time monitoring of real-time measurement management system.

A Design and Implementation of Personal Vessel Monitoring System Based on Context Aware (상황인식 기반 개인 선박 상태감시시스템 설계 및 구현)

  • Shin, Do-Sung;Lee, Seong-Ro
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.112-118
    • /
    • 2011
  • Ship can be faced with more dangerous situations than ground vehicles due to the opened surroundings, sea. Therefore, it is very important to prevent the ship emergency by finding risk factor. In this paper, We propose context-aware monitoring system which that frequently check the condition of ship using the data that get through the installed sensor in the ship as gyro-sensor, strain-gage sensor. We analyzed sensor data through backpropagation algorithm and the Condition and Safety Information of sailing ship is transmitted to the crew's personal mobile device in the ship. Thus, moving crew can check the ship's condition in real time. As a result, we obtained about 95% accuracy for fire risk context and about 89% accuracy for body of Ship risk context in the simulated experiments.