• Title/Summary/Keyword: Fire judgment

Search Result 36, Processing Time 0.027 seconds

The Study about Fire Judgment Method on Hair Dryer (모발건조기 화재 감정 기법에 관한 연구)

  • Moon, Hyun-Wook;Gil, Hyung-Jun;Kim, Dong-Ook;Kim, Dong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2140-2141
    • /
    • 2011
  • 본 논문에서는 생활공간에서 발생하는 모발건조기로 인한 전기화재의 화재 감정 기법에 관하여 알아보았다. 모발건조기의 전원장치, 제어장치, 발열장치, 송풍장치 등의 구조분석과 화재 재현 실험을 통한 각 요소의 화제 위험성 분석으로 모발건조기의 화재 현장 조사 및 감정 포인트에 대해 알아보았다. 그래서 모발건조기에서 발생하는 전기 화재의 정확한 조사 및 감정을 통해 앞으로 일어날 수 있는 전기화재를 예방하고자 한다.

  • PDF

Experimental Study on Ignition and Explosion Hazard by Measuring the Amount of Non-volatile (NVR) and Explosion Limit of Biodiesel Mixture (바이오디젤 혼합물의 가열잔분측정과 폭발한계 측정을 통한 발화 및 폭발위험성에 대한 실험적인 연구)

  • Kim, Ju Suk;Koh, Jae-Sun
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.182-193
    • /
    • 2022
  • Purpose: By measuring and evaluating the risk of biodiesel through non-volatile residue (NVR) and flash point and explosion limit measurement at a specific temperature according to ASTM test standards, the risk of chemical fire causative substances is identified and a universal evaluation method By derivation and securing the risk-related data of the material, it can be used for the identification and analysis of the cause of the fire, and it can be applied to the risk assessment of other chemical substances Method: In order to measure the risk of biodiesel, it was measured using the non-volatile residue(NVR) measurement method, which measures how much flammable liquid is generated at a specific temperature. Heating was tested by applying KS M 5000: 2009 Test Method 4111. In addition, the flash point was measured using the method specified in ASTM E659-782005, and the energy supply method was measured using the constant temperature method. In addition, the explosion limit measurement was conducted in accordance with ASTM E 681-04 「Standard test method for concentration limits of flammability of chemicals(Vapors and gases)」 test standard. Result: As a result of checking the amount of combustible liquid by the non-volatile residue (NVR)measurement method, the non-volatile residue(NVR) of general diesel when left at 105±2℃ for 3 hours was about 30% (70% of volatile matter) and about 4% of biodiesel. In addition, similar results were obtained for the non-volatile residue(NVR)heating temperature of 150±2℃, 3 hours and 200±2℃ for 1 hour, and white smoke was generated at 200℃ or higher. In addition, similar values were obtained as a result of experimentally checking the explosion (combustion) limits of general diesel, general diesel containing 20% biodiesel, and 100% biodiesel. Therefore, it was confirmed that the flammability risk did not significantly affect the explosion risk. Conclusion: The results of this study suggested the risk judgment criteria for mixtures through experimental research on flammable mixtures for the purpose of securing the effectiveness, reliability, and reproducibility of the details of the criteria for determining dangerous substances in the existing Dangerous Materials Safety Management Act. It will be possible to provide reference data for the judgment criteria for flammable liquids that are regulated in the field. In addition, if the know-how for each test method is accumulated through this study, it is expected that it will be used as basic data in the research on risk assessment of dangerous substances and as a basis for research on the determination of dangerous substances.

Utilization and Excavation Practices of Fire-Fighting Vulnerable Zone Model (소방취약지 모델의 활용 및 적용사례 발굴)

  • Choi, Gap Yong;Chang, Eun Mi;Kim, Seong Gon;Cho, Kwang-Hyun
    • Spatial Information Research
    • /
    • v.22 no.3
    • /
    • pp.79-87
    • /
    • 2014
  • In order to foster rapid disaster response and public life protection, National Emergency Management Agency has been trying to spread 'Emergency Rescue Standard System' on a national scale since 2006. The agency has also intensified management of firefighter's safety on disaster site by implementing danger predication training, specialized training and education and safety procedure check as a part of safety management officer duties. Nevertheless, there are limitations for effective fire fighting steps, such as damage spreading and life damage due to unawareness of illegal converted structure, structure transformation by high temperature and nearby hazardous material storage as well as extemporary situation handling endangered firefighter's life. In order to eliminate these limitations there is a need for an effort and technology application to minimize human errors such as inaccurate situational awareness, wrong decision built on experience and judgment of field commander and firefighters. The purpose of this study is to propose a new disaster response model which is applied with geospatial information. we executed spatial contextual awareness map analysis using fire-fighting vulnerable zone model to propose the new disaster response model and also examined a case study for Dalseo-gu in Daegu Metropolitan City. Finally, we also suggested operational concept of new proposed model on a national scale.

A Study on Leaking amount Test of Control Damper - For a Performance Based Designed of Smoke Control System - (제연댐퍼 누설량 시험에 관한 연구 - 제연시스템의 성능위주설계를 위하여 -)

  • Choi, Kyu-Chool;Song, Yun-Suk;Cha, Jong-Ho
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.131-137
    • /
    • 2009
  • This study measured smoke control damper leaking amount of condition of various kinds examination regarding AMCA Standard 500-D-98. As result of study establish because smoke control damper leaking amount performance curve that use tester data of engineering applies right design method of smoke control system and test method design, drawing examination, performance test and do so that right comprehension and performance about skill may be defined. Also user wishes to prove performance of smoke control system and construct smoke control system of reliable performance-based design derive smoke control damper quality improvement continuously selection of smoke control damper by performance judgment of performance curve.

Standardization of Underground Shopping Center Address System for the Three-Dimensional GIS-based Emergency Management (3차원 GIS기반의 소방방재를 위한 지하상가 주소체계 표준화)

  • Ha, Byeong Po;Kang, In Joon;Hong, Soon Heon;Park, Dong Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.63-69
    • /
    • 2014
  • Due to population growth and urban development in construction technology has expanded living space, underground construction as public transport as has been extended to the ground and underground urban traffic congestion increases. This underpass Stations sphere of influence this development was the center of the living space, space-time became a cultural space. However underpass ground space and time and space are enormous difficulties in contrast visibility due to smoke when light levels are low fire occurs, momentary loss of judgment errors due to a sense of orientation, rapid diffusion and ambient oxygen deficiency due to acquisition limitations, such as the Open resulting in property damage and personal injury. The purpose of this study is to analyze the existing system with respect to the address of the underground shopping center and system for presenting an address to the underground shopping mall in the basement of the straight and circular in connection with the street name address. Also can be known only to evacuate their citizens to address the position in the event of a fire inside the basement through the underground shopping mall address standardization system, the fire department only address exact location is being judged will be identified.

A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type (하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

A Study on the Flammability and Combustion Risk of Biodiesel Mixture (바이오디젤 혼합물의 인화 및 연소 위험성에 관한 연구)

  • Kim, Ju Suk;Ko, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.10-24
    • /
    • 2021
  • Purpose: The purpose of this study is to determine the dangers of biodiesel and general diesel mixtures currently used as alternative fuels by equipment (tag method and penski Marten method) and to determine the difference between flash point and combustion point (closed, open) according to test methods. It is intended to be used as a reference material for identification and evaluation of firecausing substances by confirming the risk of mixtures by comparative analysis and measurement, and establishing a risk assessment method for chemical substances. Method: Flash point test method and result treatment were tested based on ASTM and KS M mode, which are tag sealing and pen schematense test methods used as flash point and combustion point test methods for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was a test equipment that satisfies the test standards of KS M 2010 with equipment produced by TANAKA of Japan. The flash point and combustion point were measured, and the flash point according to the test method of biodiesel and general diesel mixture ( Closed, open), and the ignition point of a mixture of biodiesel and general diesel was compared and analyzed for ignition risk compared with conventional diesel. Results: Looking at the experimental results, first, as an analysis of the risk of flammability of the mixture, the flash point of a substance containing 70% biodiesel was found to be about 92℃ based on general diesel with a flash point of 64.5℃, and gasoline and biodiesel or When the biodiesel mixture was synthesized, it was confirmed that the flash point tends to decrease. In addition, the difference between the flash point and the combustion point was analyzed as about 20 ~ 30℃, and when a small amount of gasoline or methanol was mixed, the flash point was lowered, but it was confirmed that the combustion point was similar to that of the existing mixture. Conclusion: In this study, in order to secure the effectiveness of the details of the criteria for judging dangerous materials in the existing Dangerous Materials Safety Management Act, and to secure the reliability and reproducibility of the judgment of dangerous materials, we confirm the criteria for judging the risk of the mixture through an experimental study on flammable mixtures. It will be able to provide reference data for experimental criteria for flammable liquids that are regulated in the field. In addition, if this study accumulates know-how on experiment by test method, it is expected that it can be used as a basis for research on risk assessment and research on dangerous goods.

A Study on HSTPA Model for Improvement of Emergency Response Training for Ships (선박의 비상대응훈련 개선을 위한 HSTPA 모델에 관한 연구)

  • Han, Ki-Young;Jung, Jin-ki;Ahn, Young-Joong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.441-447
    • /
    • 2019
  • Since emergency response training for maritime safety and safety education of maritime education institutions are conducted based on the set scenarios and education contents, there are limitations in the reduction of human error and response to various situations. Although there is a need for improvement, there is no way to improve response capabilities by assessing existing education training and securing diversity in situations. This study proposes a theoretical procedure analyzer method to model the diversity of situations for the improvement of emergency response training. This paper defines the human and system theoretical procedure analysis model (HSTPA) based on the organic relationship of the source and system. The limitations of the existing training were derived by analyzing the errors that each component could produce and applying them to the fire response training scenarios requiring vertical reporting systems and responses. The segmentation and inspection of training scenario considerations applying the proposed HSTPA model is believed to help create diverse and realistic scenarios in emergency response training and education, and improve the situation judgment understanding and response capabilities of the subjects.

Characteristics of Positive Pressure Distribution in Vertical Drainage Method to Prevent Buoyance (부력방지를 위한 연직배수공법의 양압력 분포 특성 분석)

  • Jongin Hong;Namcheol Kim;Youngshin Park;Donghyuk Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.10
    • /
    • pp.33-39
    • /
    • 2023
  • As interest in the use of underground spaces increases, safety against water pressure acting on underground structures is required. In Korea, various buoyancy prevention methods are used to control such underground water pressure, and among them, the vertical drainage method with excellent economic efficiency, constructionability and stability has recently been introduced and applied. However, in the case of the vertical drainage method designed and constructed in the field, it is often designed and constructed depending on numerical analysis, making it difficult to expect practical stability judgment. Accordingly, in this study, an experiment was conducted to measure both pressure by installing a vertical drainage system using a model soil. Based on the measured value by the experiment and the numerical analysis value, we intend to compare and analyze the action positive pressure and use it as basic data for field application.

A Study on Animation Character Face Design System Based on Physiognomic Judgment of Character Study in the Cosmic Dual Forces and the Five Elements Thoughts (음양오행(陰陽五行)사상의 관상학에 기반한 애니메이션 캐릭터 얼굴 설계 시스템 연구)

  • Hong, Soo-Hyeon;Kim, Jae-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.7
    • /
    • pp.872-893
    • /
    • 2006
  • In this study, I classify the elements of physiognomic judgment of character with regard to form and meaning from a visual perspective based on physiognomic judgment of character study in 'the cosmic dual forces and the Five Elements theory'. Individual characters for each type are designed using graphic data. Based on that, design system of individual characters for each personality type is investigated using Neural Network system. Faces with O-Haeng (Five Elements) shapes are shown to constitute the system with ${\pm}0.3%$ degree of error tolerance for the non-loaming input data. For the shapes of Chinese characters 'tree, fire, soil, gold and water', their MSE(Mean Square Error) are 0.3, 0.3, 0.2, 0.5, 0.2. It seems to be the best regarding the scoring system which ranges from 0 to 5. Therefore, this system might be regarded to produce the most accurate facial shape of character automatically when we input character's personality we desire to make.

  • PDF