• Title/Summary/Keyword: Fire judgment

Search Result 36, Processing Time 0.027 seconds

Research about Improvement Way of Fire Investigation System - Regarding Product Liability Responsibility Law - (화재조사 제도의 개선방안에 관한 연구 - 제조물 책임법과 관련하여 -)

  • Mun, Yong-Soo;Kong, Ha-Sung;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.105-111
    • /
    • 2008
  • Improvement of fire investigation system is required to supplement problem that can happen after product liability law enforcement of our country. This treatise searches special quality of inside and outside of the country fire investigation that was enforced present with theoretical background of manufacture water responsibility law and compared. And is based and grasped objective and hangup in police fire investigation, fire fighting fire investigation, engine fire investigation of private fire judgment. By improvement way accordingly first, proposed fire emotion connection studies and establishment and connoisseurship qualification system establishment etc. in the common people private fire diet, judgment, analysis company's necessity second, fire fighting of fire investigation system, police's member anger third, college.

A Study on the Unique point about the Tracking at Electrical fire spot (화재현장에서 분석 절차에 따른 전기화재 조사기법 개발)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2130-2131
    • /
    • 2011
  • Electric fire breaks out by various causes such as electric short, overload(over current), leakage current, poor contact, static electricity, insulation deterioration, partial disconnection and etc. In this paper, we studied analysis technique for scientific and systematic judgment for distinction of electricity fire existence and nonexistence, and described about electricity fire cause analysis process for collecting physical evidences. We handled external form analysis, Substance extension analysis, X-ray transmission analysis, cross-section analysis, thermal analysis, chemical structure analysis, surface structure analysis, component analysis, electrical properties analysis, and circuit analysis by analysis technique for electricity fire cause judgment. We expect that analysis technic elevation and correct cause of fire analysis of scene of a fire investigators and analysts through this paper which see help.

  • PDF

Scientific fire investigation by NFPA 921 CODE based on frozen warehouse fire case (냉동창고 화재 사례를 기반으로 하는 NFPA 921 CODE에 의한 과학적 화재조사 연구)

  • Park, Kyong-Jin;Lee, Yong-KI;Cha, Sung-Sig;Jung, Dong-Young;Kim, Jang-Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.78-85
    • /
    • 2018
  • In this study, we investigated the cases where there were many opinions in the judgment of the cause of ignition in the case of 20 cases of frozen warehouse fire that occurred in 2017.The research methodology is the scientific fire survey method prescribed by the NFPA 921 CODE. Scientific fire investigation method is fire investigation method by logical reasoning through hypothesis setting, minimizing errors in judgment of ignition source. On the other hand, unscientific fire investigation methods cause many errors by the intervention of irrational factors such as subjective estimation, reasoning judgment, etc. This eventually leads to the problem of human and material responsibility and academic deterioration. In particular, fire not seen as compared to sighted fire makes more errors in ignition sources in the cause investigation. In this study, we set the hypothesis A and hypothesis B based on the review of the fire investigation report and the field survey on the fire case of the cold storage warehouse front line that occurred at ** city ** Mart in 2017.The set hypothesis was tested by the NFPA 921 code. This analytical method will be constructed by NEW Paradigm as a source of fire that is not seen in the future and a source of ignorant fire.In addition, the experimental data of this study will be used to inform the manufacturer and operator of the refrigeration warehouse and serve as basic data for fire prevention.

Development of Fire Control System with an Analysis of Impact Vibration and Impact Energy (충격체의 진동 및 충격량 분석을 이용한 사격 통제장비 개발)

  • Lee, Dong-Hee;Lee, Jong-Heon;Youn, Ju-Houc;Park, Noh-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.58-63
    • /
    • 2011
  • This paper presents a development of a fire control system with an intelligent judgment algorithm of hit or not. The presented algorithm analyzes an impact energy and impact signals according to impact materials. And the detected signals are used to judge the correct hit or not. Furthermore, Zigbee wireless communication technology is applied in the developed fire control system. The wireless communication technology can supply a simple installation of the practical system and free from ageing of communication wire. The presented system is verified in the practical fire test, and the results show the effectiveness of the development system.

Fire Simulations (화재시뮬레이션)

  • Kim Sang-Moon;Yoon Sang-Youl;Kim Kyung-Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.1
    • /
    • pp.8-13
    • /
    • 2006
  • Fire simulation has been developed for decades to analyze fire cases and provide a tool to study fundamental fire dynamics and combustion. There are three way of fire simulation which are a full scale simulation, an experimental simulation and a computational simulation. In case of a full scale simulation, because a higher cost, a higher risk, more efforts are needed, a demand for it has been decreased. But recently a demand for an experimental simulation and a computational simulation has been increased. A computational simulation has several advantages; lower cost, short period, many case studies, more visual results, a quantitative result and etc. FDS(Fire Dynamics Simulator) which has been developed in BFRL(Building and Fire Research Laboratory), NIST(National Institute of Standards and Technology) is a popular world wide code for fire simulation. Lack of accurate predictions by the model could lead to erroneous conclusions with regard to fire safety. All results should be evaluated by the informed judgment of the qualified user.

  • PDF

A Study on Adhesion Test Methods for Fire Hose (소방호스 밀착강도시험방법에 관한 연구)

  • 김준배;백창선;김학진
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.66-74
    • /
    • 2001
  • In order to improve the adhesion test methods for fire hose, 7 kinds of standards (KOFEIS, UL, FM, NFPA, BS, Chinese standard, JIS, JFEII standard) in 5 countries (Korea, USA, UK, China, Japan) were compared and adhesion tests were conducted by using the samples choosed randomly from the product produced in Korea. It was concluded that the sample size, the rate of seperation of a strip of the lining from the janet and standard judgment should be more differed and divided in accordance with the fire hose number in adhesion test to get the high Quality of fire hose.

  • PDF

A Study on the Proposal of Amendment of Laws and Regulations on the Improvement of Defect Determination Criteria for Painting Work and the Establishment of Replacement Cycle for Fire door (도장공사 하자판정기준 개선 및 방화문 교체 주기 설정에 관한 법령 개정안 제안 연구)

  • Kim, Soo-Yeon;Kwon, Young-Jin;Kim, Yun-Seong;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.95-96
    • /
    • 2022
  • Based on the analysis of defects occurring before and after painting work, this study intends to derive a reasonable improvement in judgment criteria and propose an amendment to the relevant law through the establishment of a clear fire door replacement cycle in terms of fire safety.

  • PDF

Seismic capacity evaluation of fire-damaged cabinet facility in a nuclear power plant

  • Nahar, Tahmina Tasnim;Rahman, Md Motiur;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1331-1344
    • /
    • 2021
  • This study is to evaluate the seismic capacity of the fire-damaged cabinet facility in a nuclear power plant (NPP). A prototype of an electrical cabinet is modeled using OpenSees for the numerical simulation. To capture the nonlinear behavior of the cabinet, the constitutive law of the material model under the fire environment is considered. The experimental record from the impact hammer test is extracted trough the frequency-domain decomposition (FDD) method, which is used to verify the effectiveness of the numerical model through modal assurance criteria (MAC). Assuming different temperatures, the nonlinear time history analysis is conducted using a set of fifty earthquakes and the seismic outputs are investigated by the fragility analysis. To get a threshold of intensity measure, the Monte Carlo Simulation (MCS) is adopted for uncertainty reduction purposes. Finally, a capacity estimation model has been proposed through the investigation, which will be helpful for the engineer or NPP operator to evaluate the fire-damaged cabinet strength under seismic excitation. This capacity model is presented in terms of the High Confidence of Low Probability of Failure (HCLPF) point. The results are validated by the proper judgment and can be used to analyze the influences of fire on the electrical cabinet.

Method for High-visibility of Online Monitoring and Fault Diagnosis System for Industrial Motor using PVA (PVA를 이용한 산업용 모터 고장진단 모니터링 시스템의 가시성을 높이는 방법)

  • Goh, Yeong-Jin;Kang, In-Won
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • Industrial Motors diagnostic equipment is highly dependent on the automation system, so if there are defects in the automation equipment, it can only rely on the operator's intuitive judgment.To help with intuitive judgment, Park's Vactor Approach(PVA) represents the current signal as a pattern of circles, so it can tell if a fault occurs when the circle is distorted. However, the failure to judge the degree of distortion of the circle pattern is the basis of the fault, so it will face difficulties. In this paper, in order to compare the faults of PVA, the period of d-axis current of PVA pulsation was mastered, so that two phase differences occurred in the same signal source. Through experiments, it is confirmed that this is a 90 degree cross formation of PVA, which is convenient for judging from the vision that there is no fault, thus helping the operator to make intuitive judgment.

Development of the Judgment Method of the Occupational Safety & Health Management System for Small & Medium Enterprises (중소규모 사업장용 안전보건경영시스템의 인증 심사방법 개발)

  • Jang, Seo-Il;Ha, Jeong-Ho;Lyu, Bo-Hyuk;Kwon, Hyuck-Myun;Kim, Tae-Ok
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.3
    • /
    • pp.1-9
    • /
    • 2009
  • The present management of the domestic and international advanced enterprises is transferring the systems and the regulations to the prevention system management. Expecially, KOSHA (Korea Occupational Safety & Health Agency) in Korea has supported to set up the OSHMS (Occupational Safety & Health Management System) by KOSHA 18001 since 1997. But small & medium enterprises (SMS) has many difficulties to set up the OSHMS system because of limited natural and human resources. In this study, the rating system as a judgment method of an OSHMS based on the certification standard of the OSHMS, which was suggested in previous study, was developed for SMS to adopt voluntarily the OSHMS, certify KOSHA 18001, and improve the safety and health level.