• Title/Summary/Keyword: Fire intensity

Search Result 166, Processing Time 0.027 seconds

Development of the Surface Forest Fire Behavior Prediction Model Using GIS (GIS를 이용한 지표화 확산예측모델의 개발)

  • Lee, Byungdoo;Chung, Joosang;Lee, Myung-Bo
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.6
    • /
    • pp.481-487
    • /
    • 2005
  • In this study, a GIS model to simulate the behavior of surface forest fires was developed on the basis of forest fire growth prediction algorithm. This model consists of three modules for data-handling, simulation and report writing. The data-handling module was designed to interpret such forest fire environment factors as terrain, fuel and weather and provide sets of data required in analyzing fire behavior. The simulation module simulates the fire and determines spread velocity, fire intensity and burnt area over time associated with terrain slope, wind, effective humidity and such fuel condition factors as fuel depth, fuel loading and moisture content for fire extinction. The module is equipped with the functions to infer the fuel condition factors from the information extracted from digital vegetation map sand the fuel moisture from the weather conditions including effective humidity, maximum temperature, precipitation and hourly irradiation. The report writer has the function to provide results of a series of analyses for fire prediction. A performance test of the model with the 2002 Chungyang forest fire showed the predictive accuracy of 61% in spread rate.

Characteristics study on fire-resistant paint used by TGA-IR (TGA-IR을 사용한 내화 도료의 특성에 관한 연구)

  • Cho, Nam-Wook;Shin, Hyun-Jun;Cho, Won-Bo;Lee, Seong-Hun;Rie, Dong-Ho;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.168-172
    • /
    • 2011
  • The iron frame of building could be collapsed or bent at $500^{\circ}C$. Therefore the fire-resistant paint should be applied for safety. This study performed the comparative analysis to show the characteristics of fireresistant paint. And then 12 products of fire resistant paint and 6 products of paints were used as samples. And the samples were analyzed by TGA (Thermogravimetric Analyzer) as analyzer for measuring the variation of weight on temper of weight by heating. When TGA analyzer could measure the variatiature, and FT-IR was measured for analyze gas components on variation on of weight by heating on 12 products of fire resistance, the samples showed to decrease 40% of weight to $800^{\circ}C$, and because paints had 50% to 40% of loss weight, it showed to be equal with loss weight of fire resistance paint on high temperature or was lower loss weight than it of fire resistance paints. However number 6 sample of fire resistance paints could show to decrease 20% of total weight on $800^{\circ}C$. And then in the case of FT-IR, fire resistance paints could show to have the high intensity of $CO_2$ spectrum as complete combustion. However paints could show to have the lower intensity of $CO_2$ spectrum, have the higher intensity of water spectrum. Therefore the TGA graph of result could be much different until $250^{\circ}C$. When it was burned, FT-IR spectrum could show to confirm the characteristics of fire resistance paints, and the characteristic could be confirmed on inorganic paint of fire resistance by weight loss of TGA.

A study on the smoke control performance of the damper exhaust system at FCEV fire in tunnel for small vehicles (소형차 전용터널 내 수소연료전지차 화재시 집중배기방식의 제연성능에 관한 연구)

  • Hong, Seo-Hee;Baek, Doo-San
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.745-756
    • /
    • 2022
  • The road tunnel is a semi-closed space that is blocked on all sides except the entrance and exit, and in the event of a fire, the smoke of the fire spreads longitudinally due to heat buoyancy caused by the fire and air currents that always exist in the tunnel. To solve this problem, smoke removal facilities are installed in road tunnels to secure a safe evacuation environment by controlling the direction of movement of smoke or directly smoking at fire points. In urban areas, the service level of urban roads decreases due to the increase in traffic due to the increase in population, and as a solution, the construction of underground roads in urban areas is increasing. When a fire occurs during hydrogen leakage through TPRD of a hydrogen fuel cell vehicle (FCEV), the fire intensity depends on the amount of leakage, and the maximum fire intensity depends on the orifice diameter of the TPRD. Considering the TPRD orifice diameter of 1.8 mm, this study analyzed the diffusion distance of fire smoke according to the wind speed of the roadway and the opening interval of the large exhaust port when the maximum fire intensity was 15 MW. As a result, it was analyzed that air flow in the tunnel could be controlled if the wind speed of the road in the tunnel was less than 1.25 m/s, and smoke could be controlled within 200 m from the fire if the damper interval was 50 m and 100 m.

INFLUENCE OF AERIAL FIRE FIGHTING ON INTENSITY OF RADIATION FROM FIRE

  • Iwata, Yusaku;Koseki, Hiroshi;Kon, Fumio
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.269-274
    • /
    • 1997
  • A large scale fire experiment was conducted through the collaboration between the Tokyo Fire Department and the National Research Institute of Fire and Disaster (NRIFD) for the purpose of studying the effectiveness of aerial fro fighting against urban fire. Ten model houses and ten collapsed model houses were arranged in an area of about $2,000\;m^2$. Water was dropped totally fourteen times by helicopters onto the model houses. In order to know influence of water drop, radiation was measured by four radiometers and four IR (Infrared) cameras, which were set around the burning area. In this report, the influence of aerial Ore fighting on fire was discussed in terms of irradiance and IR images. Data of irradiance, flame temperature and flame area showed that influence of each water drop continued only at most a minute.

  • PDF

A Safety Evaluation of Cable Tunnel Exposed to Fire (화재피해 통신구의 안전진단)

  • 김지상;김형우;김효환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.221-226
    • /
    • 1994
  • A safety evaluation of cable tunnel, which is a concrete box structure with telecommunication facilities in it, exposed to fire is given. The immediate field observation was performed to find out any sign of sudden structural failure. In some region, where the fire intensity was heavy, the spalling of concrete cover in upper slab occurred. Next, more careful investigation was done with proper non-desturctive testing methods and structural analysis taking into account the changes in material properties due to fire. It seems that there is no severe damage on concrete, reinforcements and over all structural system.

  • PDF

Fire Detection Algorithm Based On Motion Information and Color Information Analysis (움직임 정보와 칼라정보 분석을 통한 화재검출 알고리즘)

  • Choi, Hong-seok;Moon, Kwang-seok;Kim, Jong-nam;Park, Seung-seob
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.180-188
    • /
    • 2016
  • In this paper, we propose a fire detection algorithm based on motion information and color information analysis. Conventional fire detection algorithms have as main problem the difficulty to detect fire due to external light, intensity, background image complexity, and little fire diffusion. So we propose a fire detection algorithm that accurate and fast. First, it analyzes the motion information in video data and then set the first candidate. Second, it determines this domain after analyzing the color and the domain. This algorithm assures a fast fire detection and a high accuracy compared with conventional fire detection algorithms. Our algorithm will be useful to real-time fire detection in real world.

High-intensity Fitness Training Among a National Sample of Male Career Firefighters

  • Jahnke, Sara A.;Hyder, Melissa L.;Haddock, Christopher K.;Jitnarin, Nattinee;Day, R. Sue;Carlos Poston, Walker S.
    • Safety and Health at Work
    • /
    • v.6 no.1
    • /
    • pp.71-74
    • /
    • 2015
  • Obesity and fitness have been identified as key health concerns among USA firefighters yet little is known about the current habits related to exercise and diet. In particular, high-intensity training (HIT) has gained increasing popularity among this population but limited quantitative data are available about how often it is used and the relationship between HIT and other outcomes. Using survey methodology, the current study evaluated self-reported HIT and diet practice among 625 male firefighters. Almost one-third (32.3%) of participants reported engaging in HIT. Body composition, as measured by waist circumference and percentage body fat, was significantly related to HIT training, with HIT participants being approximately half as likely to be classified as obese using body fat [odds ratio (OR) = 0.52, 95% confidence interval (CI) = 0.34-0.78] or waist circumference (OR = 0.61, 95% CI = 0.37-0.98). Those who engaged in HIT were more than twice as likely as those who did not (OR = 2.24, 95% CI = 1.42-3.55) to meet fitness recommendations. Findings highlight directions for future prevention and intervention efforts.

Experimental Study on the Fire Whirl Characteristics of Oriental Oak Leaves (굴참나무 낙엽의 Fire Whirl 특성에 관한 실험연구)

  • Hong, Ki-Bae;Lee, Jae-Ha;Bae, Seung-Yong;Ryou, Hong-Sun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.17-21
    • /
    • 2009
  • The fire whirl occurring in the urban and/or wildland fire is generated by the instabilities of atmosphere. The fire whirl is a rare phenomenon, but highly destructive because it has high inhalation and lift force. In this study, experimental study is performed with oriental oak leaves, for investigating of the fire whirl characteristics occurred in wildland fire. As a result of experiment, the circulation intensity increases as increasing of the induced air velocity, and then the fire whirl occurs. Also, the heat release rate and flame height increase 22% and 18% in highest circulation.

Smart Fire Image Recognition System using Charge-Coupled Device Camera Image (CCD 카메라 영상을 이용한 스마트 화재 영상 인식 시스템)

  • Kim, Jang-Won
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.77-82
    • /
    • 2013
  • This research suggested smart fire recognition system which trances firing location with CCD camera with wired/wire-less TCP/IP function and Pan/Tilt function, delivers information in real time to android system installed by smart mobile communication system and controls fire and disaster remotely. To embody suggested method, firstly, algorithm which applies hue saturation intensity (HSI) Transform for input video, eliminates surrounding lightness and unnecessary videos and segmentalized only firing videos was suggested. Secondly, Pan/Tilt function traces accurate location of firing for proper control of firing. Thirdly, android communication system installed by mobile function confirms firing state and controls it. To confirm the suggested method, 10 firing videos were input and experiment was conducted. As the result, all of 10 videos segmentalized firing sector and traced all of firing locations.

Fire Severity Mapping Using a Single Post-Fire Landsat 7 ETM+ Imagery (단일 시기의 Landsat 7 ETM+ 영상을 이용한 산불피해지도 작성)

  • 원강영;임정호
    • Korean Journal of Remote Sensing
    • /
    • v.17 no.1
    • /
    • pp.85-97
    • /
    • 2001
  • The KT(Kauth-Thomas) and IHS(Intensity-Hue-Saturation) transformation techniques were introduced and compared to investigate fire-scarred areas with single post-fire Landsat 7 ETM+ image. This study consists of two parts. First, using only geometrically corrected imagery, it was examined whether or not the different level of fire-damaged areas could be detected by simple slicing method within the image enhanced by the IHS transform. As a result, since the spectral distribution of each class on each IHS component was overlaid, the simple slicing method did not seem appropriate for the delineation of the areas of the different level of fire severity. Second, the image rectified by both radiometrically and topographically was enhanced by the KT transformation and the IHS transformation, respectively. Then, the images were classified by the maximum likelihood method. The cross-validation was performed for the compensation of relatively small set of ground truth data. The results showed that KT transformation produced better accuracy than IHS transformation. In addition, the KT feature spaces and the spectral distribution of IHS components were analyzed on the graph. This study has shown that, as for the detection of the different level of fire severity, the KT transformation reflects the ground physical conditions better than the IHS transformation.