• Title/Summary/Keyword: Fire information system

Search Result 775, Processing Time 0.027 seconds

Wireless Sensor Networks based Forest Fire Surveillance System

  • Son, Byung-Rak;Kim, Jung-Gyu
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.123-126
    • /
    • 2005
  • Wireless Sensor Networks will revolutionize applications such as environmental monitoring, home automation, and logistics. We developed forest fire surveillance system. In this paper, Considering the fact that in Korea, during November to May, forest fires occur very frequently causing catastrophic damages on the valuable environment, Although exists other forest fire surveillance system such as surveillance camera tower, infrared ray sensor system and satellite system. Preexistence surveillance system can't real-time surveillance, monitoring, database and automatic alarm. But, forest fire surveillance system(FFSS) support above. In this paper, we describes a system development approach for a wireless sensor network based FFSS that is to be used to measure temperature and humidity as well as being fitted with a smoke detector. Such a device can be used as an early warning fire detection system and real-time surveillance in the area of a bush fire or endangered public infrastructure. Once the system has being development, a mesh network topology will be implemented with the chosen sensor node with the aim of developing a sophisticated mesh network.

  • PDF

A Study on Fire Evacuation Guidance System using Indoor Spatial Information from Beacon (실내공간정보를 활용한 비콘기반 화재위험감지와 재실자 피난지원 서비스에 관한 연구)

  • Lee, Sun Min;Kim, Tae-Kyung;Hong, Sung-Moon;Kim, Ju-hyung;Kim, Jae-Jun
    • Journal of KIBIM
    • /
    • v.6 no.3
    • /
    • pp.15-23
    • /
    • 2016
  • The purpose of this study is to present the possibility of adopting beacons to implement the fire evacuation guidance system in order to reduce the evacuation time for a fire in complex buildings. A beacon-based evacuation system can quickly detect a fire's origin, optimal path of evacuation involved with the exits and the location of evacuees using information collected by the proposed system. The assessment is conducted by integrating different scenario models including fire simulation. Based on the research result, beacon is an effective tool to warn potential hazards or to provide early detection and a safe escape.

Synthetic Circumstantial Judgement System Applied Recognition of Fire Levels Model (화재 상황 인식 모델을 적용한 종합 상황 판단 시스템)

  • Song, Jae-Won;Lee, Se-Hee;An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1275-1281
    • /
    • 2011
  • This paper presents synthetic circumstantial judgement system that detects and predicts a fire in subway station. Unlike conventional fire surveillance systems that judge the fire or not through smoke, CO, temperature or variation of temperature, a proposed system discovers a fire more easily or gives the alarm high possibility of fire to operator through recognition of fire levels based on Fuzzy Inference System using by FCM and information of objects from video data.

  • PDF

Design of the Integrated Fire Automation System(IFAS) on based P-Type Fire Control Panel (P형 수신기 기반 통합화재 자동 시스템의 설계)

  • Kim, Hyun-Ju;Park, Jae-Heung;Seo, Yeong-Geon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.12
    • /
    • pp.133-142
    • /
    • 2010
  • P-type fire control panel, currently in use, has a big hazard that can cause the large scaled human death tolls and property damage in the massive fire because it is difficult to identify in real time the location of fire outbreak and whether search-device are broken down or not. In this paper, I suggest that the integrated fire automation system on based p-type fire control panel should be used, which can detect in real time the signal that occur when whether search-device are broken down or not, and can detect the arisen circumstances information of p-type fire control panel on the fire signal in the far away. The devised systems have designed and embodied the analysis of circumstances information and module that can analyze the circumstances information from the p-type fire control panel and the part of internet access installment which can gather and deliver the circumstances information from the fire prevention facility receiver.

Smart Fire Fighting Appliances Monitoring System using GS1 based on Big Data Analytics Platform (GS1을 활용한 빅데이터 분석 플랫폼 기반의 스마트 소화기구 모니터링 시스템)

  • Park, Heum
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.4
    • /
    • pp.57-68
    • /
    • 2018
  • This paper presents a smart firefighting appliances monitoring system based on big data analytics platform using GS1 for Smart City. Typical firefighting appliances are fire hydrant, fire extinguisher, fire alarm, sprinkler, fire engine, etc. for the fire of classes A/B/C/D/E. Among them, the dry chemical fire extinguisher have been widely supplied and 6 millions ones were replaced for the aging ones over 10 years in the past year. However, only 5% of them have been collected for recycling of chemical materials included the heavy metals of environment pollution. Therefore, we considered the trace of firefighting appliances from production to disposal for the public open service. In the paper, we suggest 1) a smart firefighting appliances system using GS1, 2) a big data analytics platform and 3) a public open service and visualization with the analyzed information, for fire extinguishers from production to disposal. It can give the information and the visualized diagrams with the analyzed data through the public open service and the free Apps.

A Study on the Improvement of the Fire Investigation System In Korea (우리나라의 화재조사제도 개선에 관한 연구)

  • Ko, G.B.;Choi, D.M.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.155-166
    • /
    • 2007
  • This study is to deduce problems and grope for its solution by investigating the general operation status about the present fire investigation in Korea. As for the problems, this study is to point out that they are application of diversion by the function of law for fire investigation, execution of individualized fire investigation by each institution, total lack of information sharing system for fire investigation, and weakness of cause investigation for arson. The reform measures are as follows: the unity of law for fire investigation, joint investigation by the related institutions, early introduction of civil fire investigation expert system, extension of special research institutes for fire investigation, introduction of system for sharing information of fire investigation, and operation of fire investigation team for cause investigation for arson.

  • PDF

Trends of Onboard Fire Extinguishing System (선박용 소화설비의 국제동향)

  • Kim, Mann-Eung
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.126-127
    • /
    • 2005
  • This paper provides information on the current issues and the progress of on-going researches relating onboard fixed fire extinguishing system in the IMO Sub-committee on Fire Protection. And also prepares to introduce the recent amendment to regulations and technical trends of the water mist fire extinguishing system and high expansion foam system.

  • PDF

Fire Detection Method Using IoT and Wireless Sensor Network

  • Park, Jung Kyu;Roh, Young Hwa;Nam, Ki hun;Seo, Hyung Yoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.8
    • /
    • pp.131-136
    • /
    • 2019
  • A wireless sensor network (WSN) consists of several sensor nodes and usually one base station. In this paper, we propose a method to monitor topics using a wireless sensor network. Fire threatens people, animals, and plants, and it takes a lot of recovery time when a fire occurs. For this reason, it is necessary to use a fire monitoring system that is easy to configure and fast to avoid fire. In this paper, we propose a fast and easily reliable fire detection system using WSN. The wireless node of the WSN measures the temperature and brightness around the node. The measured information is transferred to the workstation and to the base station. The workstation analyzes current and historical data records to monitor the fire and notify the manager.

Forest Fire Monitoring System Using Remote Sensing Data

  • Hwangbo, Ju-Won;Yu, Ki-Yun
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.747-749
    • /
    • 2003
  • For forest fire monitoring in relatively cool area like Siberia, design of Decision Support System (DSS) is proposed. The DSS is consisted of three different algorithms to detect potential fires from NOAA AVHRR image. The algorithm developed by CCRS (Canada Center for Remote Sensing) uses fixed thresholds for multi-channel information like one by ESA (European Space Agency). The algorithm of IGBP (International Geosphere Biosphere Program) involves contextual information in deriving fire pixels. CCRS and IGBP algorithms are rather liberal compared to more conservative ESA algorithm. Fire pixel information from the three algorithms is presented to the user. The user considers all these information in making decision about the location fire takes place.

  • PDF

A Hybrid Fire Fighting Control Intelligent System using Rules and Cases in Integrated Platform Management System (통합플랫폼관리체제에서 규칙 및 사례기반의 하이브리드 화재진압통제 지능시스템)

  • 현우석;김용기
    • Journal of Intelligence and Information Systems
    • /
    • v.6 no.2
    • /
    • pp.15-27
    • /
    • 2000
  • The paper proposes a hybrid fire fighting control intelligent system(H-FFIS) using rules and cases to detect fire in Integrated Platform Management System. By far most conventional systems have been based on rule-based system in which expert knowledges are expressed with production rules. It is hard to express the knowledges to detect fire with production rules only. The knowledges of fire detection are often based on previously encountered situations of fires. For improvement of system capability renewing and adding of rules is needed in an already build-up system and such adding and renewing procedures could hinder users from fluent utilization of the system. We design and implement H-FFIS. Compared with rule-based FFIS(Fire Fighting control Intelligent System), H-FFIS extended with case-based reasoning shows that the system proposed here can lead to an improvement in fire detection rate.

  • PDF