• 제목/요약/키워드: Fire industry

검색결과 506건 처리시간 0.024초

핵심 객체 추출에 기반한 비주거 시설의 화재불꽃 추출에 관한 기초 연구 (A Basic Study on the Fire Flame Extraction of Non-Residential Facilities Based on Core Object Extraction)

  • 박창민
    • 디지털산업정보학회논문지
    • /
    • 제13권4호
    • /
    • pp.71-79
    • /
    • 2017
  • Recently, Fire watching and dangerous substances monitoring system has been being developed to enhance various fire related security. It is generally assumed that fire flame extraction plays a very important role on this monitoring system. In this study, we propose the fire flame extraction method of Non-Residential Facilities based on core object extraction in image. A core object is defined as a comparatively large object at center of the image. First of all, an input image and its decreased resolution image are segmented. Segmented regions are classified as the outer or the inner region. The outer region is adjacent to boundaries of the image and the rest is not. Then core object regions and core background regions are selected from the inner region and the outer region, respectively. Core object regions are the representative regions for the object and are selected by using the information about the region size and location. Each inner region is classified into foreground or background region by comparing its values of a color histogram intersection of the inner region against the core object region and the core background region. Finally, the extracted core object region is determined as fire flame object in the image. Through experiments, we find that to provide a basic measures can respond effectively and quickly to fire in non-residential facilities.

GS1을 활용한 빅데이터 분석 플랫폼 기반의 스마트 소화기구 모니터링 시스템 (Smart Fire Fighting Appliances Monitoring System using GS1 based on Big Data Analytics Platform)

  • 박흠
    • 디지털산업정보학회논문지
    • /
    • 제14권4호
    • /
    • pp.57-68
    • /
    • 2018
  • This paper presents a smart firefighting appliances monitoring system based on big data analytics platform using GS1 for Smart City. Typical firefighting appliances are fire hydrant, fire extinguisher, fire alarm, sprinkler, fire engine, etc. for the fire of classes A/B/C/D/E. Among them, the dry chemical fire extinguisher have been widely supplied and 6 millions ones were replaced for the aging ones over 10 years in the past year. However, only 5% of them have been collected for recycling of chemical materials included the heavy metals of environment pollution. Therefore, we considered the trace of firefighting appliances from production to disposal for the public open service. In the paper, we suggest 1) a smart firefighting appliances system using GS1, 2) a big data analytics platform and 3) a public open service and visualization with the analyzed information, for fire extinguishers from production to disposal. It can give the information and the visualized diagrams with the analyzed data through the public open service and the free Apps.

화목 연료 난방설비의 화재 위험 감소 방안에 관한 이론적 연구 (Study on the effective response method to reduce fire risk of wood fuel heating system)

  • 박경진;이봉우;이근출;남기훈
    • 한국산업융합학회 논문집
    • /
    • 제22권2호
    • /
    • pp.163-171
    • /
    • 2019
  • Recently, rural housing in urban areas has been increasing due to the improvement of income level. With the increase of the construction of the power house, the installation of the heating system using the harmonious fuel for the purpose of heating and the beauty of the room is increasing rapidly. In addition to the increasing use of firewood heating equipment, the incidence of fire is also increasing. Analysis of the National Fire Data System of the Fire Department The result of the analysis of the National Fire Data System Many parts of the fire are incinerated by the accumulation of tar due to the incompleteness of periodic cleaning inside the cylinder. The distance between the fire extinguisher and the combustible materials such as ceiling, Resulting in fire. In addition, it was found that much of the fire of the firewood heating system in the time zone occurs during the sleeping and resting time and there is not enough time for the residents to cope. This, in turn, causes serious harm to the lives and property of the users of the pyrotechnic heating system. Therefore, in this study, domestic and foreign standards and laws related to fuel oil heating facilities were analyzed and 12 cases of fire accidents were analyzed. Through the revision of the fire prevention and firefighting facilities installation and maintenance law, the installation standards of the alarm and fire extinguishing facilities were presented.

국내 제조업 화재감시자 운영 실태 분석 - 개정 산업안전보건법 중심 (Analysis of the Operation of Fire Observers in the Domestic Manufacturing Industry - Focusing on the Revised Occupational Safety and Health Act)

  • 김경민;서용윤;이종빈;장성록
    • 한국안전학회지
    • /
    • 제38권3호
    • /
    • pp.77-84
    • /
    • 2023
  • Welding and cutting, which are representative tasks in handling firearms at industrial sites, are the basis for production and maintenance processes across all industries. They are also essential in the root industry. Specifically, they are widely used in the manufacturing industry, including equipment industries such as shipbuilding, automobiles, and chemicals, and subsequent maintenance work and general facility repair. However, such hot work carries a high fire risk owing to sparks scattering and inadequate management, resulting in a high occurrence of accidents. In response, the government and relevant organizations have recently revised the Occupational Safety and Health Act to prevent accidents during hot work. These revisions impose more stringent regulations than before, which are expected to help prevent actual fire accidents. However, whether the fire observer system, which is the core element of the revision, would be practically applied and maintained is unclear. Therefore, this study compared the fire observer system in the revised Occupational Safety and Health Act with those in the laws and systems of developed countries, conducted interviews with safety and health experts to assess the suitability of the new system for fire observer operations, and improvement plans were derived accordingly. Therefore, the laws and systems of developed countries grant more authority to fire observers compared with those of Korea. Moreover, professional training in handling emergency is required. Interviews with safety and health experts revealed that regardless of company size, the same operating standards were applied, and standards for deploying fire observers in various locations were unclear. Furthermore, there was a lack of professional education and training, and the role and authority of fire observers were limited. These findings revealed a problem in this sector. The results of this study are expected to serve as basic data for establishing a practical system for placing fire observers and supplementing laws, guidelines, and systems for preventing fire accidents.

APPLICATION OF FIRE RESEARCH TO BUILDING FIRE SAFETY DESIGN - CURRENT BENEFITS AND FUTURE NEEDS

  • Bressington, Peter;Johnson, Peter
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.392-403
    • /
    • 1997
  • There is a strong international move towards performance based fire regulations for buildings with New Zealand and Australia at the forefront of research in this fold. The reform of regulations is thought to offer more innovation and flexibility in building design and greater cost effectiveness in construction. An important part of the research in this area is related to the development of agreed approaches to fire safety design, such as the Fire Code Reform Centre's "Fire Engineering Guidelines" or New Zealand's "Fire Engineering Design Guide". Such design process documents have incorporated or referenced much of the latest research in areas such as: tenability criteria fire compartment models egress models risk assessment. Use of such design guidelines or equivalents in major projects in countries such as Hong Kong and Australia have highlighted where fro engineering can offer real benefits to building designers and ultimately building owners and operators. However, there is still much research to be done and use of a systematic, logical design approach clearly identifies where design data or modelling techniques are still urgently required. Such areas are: fire growth rates and peak heat release rates for non-residential occupancies pre-movement times related to egress experimental validation and limits of applicability of CFD and other compartment Ire models probability/reliability data on fire protection systems for risk based analysis. Examples from case studies will be shown where lack of such research and poor judgement can lead to inferior design solutions or where unnecessarily conservative designs can lead to cost excesses. In summary, the link between Ire engineering designers and the research community is very important to highlight areas of fire research that will have the most benefit to the building and construction industry.nstruction industry.

  • PDF

전기차 화재 실험 및 대응방안에 관한 연구 (An Experiment Study on Electric Vehicle Fire and Fire Response Procedures)

  • 남기훈;이준식
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.63-70
    • /
    • 2024
  • Lithium-ion batteries (LIB) are widely used in various sectors, such as transportation (e.g., electric vehicles (EV)) and energy (e.g., energy storage facilities) due to their high energy density, broad operating temperature (-20 ℃ ~ 60 ℃), and high capacities. LIBs are powerful but fragile on external factors, including pressure, physical damage, overheating, and overcharging, that cause thermal runaway causing fires and explosions. During a LIB fire, a large amount of oxygen is generated from the decomposition of ionogenic materials. A water fire extinguisher that helps with cooling and suffocating must be essentially required at the same time. In fact, however, it is difficult to suppress LIB fires in the case of EVs because a LIB is installed with a battery pack housing that interrupts direct extinguishing by water. Thus, this study aims to investigate effective fire extinguishing measurements for LIB fires by using an EV. Relevant documents, including research articles and reports, were reviewed to identify effective ways of LIBs fire extinguishing. A real-scale fire experiment generating thermal runaway was carried out to figure out the combustion characteristics of EVs. This study revealed that the most effective fire extinguishing measurements for LIB fires are applying fire blankets and water tanks. However, there is still a lack of adequate regulation and guidelines for LIB fire extinguishment. Taking this into account, developing functional fire extinguishment measurements and available regulatory instruments is an urgent issue to secure the safety of firefighters and citizens.

소방차량의 안전벨트 설계 및 정책제안 (Design and Policy of Seat Belt for fire Engines)

  • 박경진;조철희;이봉우
    • 한국산업융합학회 논문집
    • /
    • 제25권6_3호
    • /
    • pp.1173-1182
    • /
    • 2022
  • According to the National Fire Agency, there were 61 traffic accidents of Fire engines in 2021. That is an increase of about 80% compared to the previous year. And the number of injuries and deaths increased by more than 300%. According to the survey of this study, less than 25% of firefighters wore seat belts of Fire engines during dispatch, contrary to the rapid increase in injuries and deaths. About the reasons for why firefighters do not wear seat belts, It can be found in aspects that are related to personal consciousness, organizational culture, and firefighting dispatch. The number of dispatches will increase in the future, this is considered to be a serious problem for the stability of the firefighting organization. In this study, a seat belt should be designed newly and proposed to improve the seat belt wearing policy.

소방기관의 조직 개편에 관한 연구 (A Study on the Reorganization of Fire Service Agencies)

  • 박경진
    • 한국산업융합학회 논문집
    • /
    • 제26권2_2호
    • /
    • pp.279-284
    • /
    • 2023
  • In this study, We analyzed that organization of fire service agencies, personnel management and firefighting activities. As a results, Many problems were found out, about ratio of administrative to firefighting personnel, retirement age, promotion, employment, Etc. T herefore, In order to carry out there mission faithful in disasters scene, We proposed that reduction of the number of administrative firefighter, abolition of the employment system candidates for fire executive positions, reducing of the retirement age and changing of the promotion system.

소방기관의 조직공정성에 관한 연구 (A Study on the Organizational Justice of Fire Service Agency)

  • 박경진;이현경
    • 한국산업융합학회 논문집
    • /
    • 제27권2_2호
    • /
    • pp.363-370
    • /
    • 2024
  • This study is about the organizational justice of fire service agency for organizational commitment and motivation of firefighters. The research data were collected from 355 firefighters nationwide using the On-nara Administrative Work Management System 2.0. The statistical processing method of the research data was analyzed using the statistical program SPSS 28.0. The study results showed that the overall level of firefighters' perception of organizational justice was slightly lower than normal, with an average score of 2.85. Regarding gender, male firefighters were more likely to believe that the organization was injustice than female firefighters. In addition, organizational justice was found to be lower among fire sergeants by rank and first aiders by responsibility.