• 제목/요약/키워드: Fire industry

검색결과 507건 처리시간 0.025초

Study on Hazard of Toner Cartridge at Recycle Facilities

  • Koseki, Hiroshi;Iwata, Yusaku;Lim, Woo-Sub
    • International Journal of Safety
    • /
    • 제11권1호
    • /
    • pp.15-18
    • /
    • 2012
  • Because of development of printing technology, toner cartridge particle becomes smaller and more dangerous. And sometimes we had incidents with dust explosion of toner cartridge particle at recycling facilities in Japan. Therefore we studied on hazard of toner particle relating with dust explosion. We found that toner particle is so dangerous compared with most organic solids, even though it does not belong to hazardous materials in the UN regulation and the Japanese Fire Service Law.

가스계 소화약제의 소화성능 평가에 관한 연구 (A Study on Fire Extinguishing Ability Evaluation of Gaseous Extinguishing Agents)

  • 임우섭;정종진;남동군;최근주;김종원
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.483-486
    • /
    • 2009
  • 국제사회의 할론계 소화약제 사용규제가 본격화 되면서 차세대 소화약제에 대한 개발은 시급한 사안으로 다가왔다. 그중에서도 청정소화약제에 해당하는 가스계 소화약제의 개발은 상당히 진척되었으며, 가스계 소화약제의 소화성능에 관한 평가는 화재발생시 인명과 재산상의 손실을 최소화하기 위한 중요한 평가요소이다. 본 연구는 기존의 이산화탄소 소화약제와 새로운 형태의 소화약제인 Novec의 소화성능을 비교 평가하기 위해서 Cup Burner Test를 이용하여 실험을 행하였으며, 에탄올, 노르말헵탄, 톨루엔과 가솔린을 원료하여 실험한 결과 Nocvec의 소화성능이 이산화탄소 소화약제보다 우수한 것으로 나타났다.

  • PDF

해양플랜트용 H-120 등급 방화 댐퍼의 성능 실험 (Performance Experiment of H-120 Class Fire Damper for Offshore)

  • 박창수
    • 한국산업융합학회 논문집
    • /
    • 제20권5호
    • /
    • pp.425-430
    • /
    • 2017
  • This study propose CAE analysis of fire damper and design of the damper control system. Through the design of the damper system for ANSYS-CFX heat transfer. As a result of the analysis, continuance equation of the damper control. Climate system. Finaily, We have obtained a fire damper solution by using orthogonal array. The fire damper of the set of fixture and alveolus are made by using a CAE software. Also, the optimum design offshore structures. The new H-120 class fire damper was designed. In the near future, fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. The test results showed that the insulation of the damper blade was an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500mm on the unexposed side as specified test standard.

티타늄 합금 폐기물의 연소 특성에 관한 실험적 연구 (Experimental study on the combustion characteristics of titanium alloy)

  • 이준식;남기훈
    • 한국산업융합학회 논문집
    • /
    • 제22권2호
    • /
    • pp.105-110
    • /
    • 2019
  • Most titanium alloy waste with cutting oil was discarded without recycling process so that it can be caused by metal and oil fires. However, there is no fire management system and studies on the titanium or titanium alloy waste in spite of high fire risk. The purpose of this experimental study is to identify the fire risk of the titanium alloy waste with cutting oil. We collected the 120g waste which was made in the biomedical titanium alloy cutting process. The waste was burned and conducted thermal image analysis with infrared camera. The experimental results which illustrated the process, characteristics, and trends of fire are presented. Firstly, the cutting oil was burned and partially the titanium alloy waste was burned. The maximum temperature of the fire was more than $650^{\circ}C$ in some specific spots. These results means when a lot of titanium alloy waste with cutting oil was ignited, this fire could connect the titanium fire. In other words, the fire has a flammable liquid fire and combustible metal fire at the same time. The experimental study could be used fire prevention, response, and investigation of the titanium alloy waste.

A Study on Building the Regional Cluster: The Case of Fire and Emergency Industrial Cluster in Samcheok-si

  • Lee, Dong-Kyu;Yang, Gi-Geun
    • International Journal of Contents
    • /
    • 제5권3호
    • /
    • pp.57-64
    • /
    • 2009
  • Korea has relied on top down development method, in which companies, research and education institutions move into the industrial complexes established by the government. However, to improve local competitiveness, the paradigm is shifting from the government initiated industrial complex to the clusters based on the cooperative network of the region. Representative case is 'Samcheok-si Fire & Emergency industry cluster construction project' that begun in 2007. AHP technique analysis results on first-stage showed that priority was on policy and network elements, and the results of second-stage analysis show that priority was on Policy incentives to internationalize the cluster and strengthen link,. Cluster branding, Sharing of organizational culture to cope with changes in environment, Creation of group learning culture. The subject of this research is limited to Samcheok-si's the Fire and Emergency Industry cluster formation project. Therefore, the research area and standard should be expanded to increase generality in further researches.

요양병원의 피난안전에 관한 연구 (A Study on Evacuation Safety of a Long-term Care Hospital)

  • 박경진
    • 한국산업융합학회 논문집
    • /
    • 제26권3호
    • /
    • pp.389-393
    • /
    • 2023
  • In this study, We analyzed that evacuation characteristics of residents, fire safety standards, evacuation facilities and flame retardation, etc to increase the evacuation safety of a long-term care hospital. Therefore, In order to improve of evacuation safety in case of fire, We proposed that an increase in the number of care workers, education, training and an amendment to the law, a change of positions of fire safety controller.

열화상카메라를 이용한 산불 화재 대응시스템 연구 (Forest Fire Response System Using Thermal Imaging Camera)

  • 윤원섭;김연규;김승준
    • 한국산업융합학회 논문집
    • /
    • 제24권6_2호
    • /
    • pp.927-935
    • /
    • 2021
  • This study conducted a study to improve the problems of the existing fire sensor system. In the case of the existing system, it took more than 3 minutes to detect a fire even at a short distance, making it difficult to extinguish the initial fire. In order to improve these problems, in this study, a fire detection system using an infrared thermal imaging camera was studied. The infrared image-based fire detection system is relatively wide and can detect fire over a long distance, so it has the advantage of being applicable to many fire detection systems. As a result of conducting a field test using the fire detection system, a fire that occurred about 2 km ahead was detected within about 10 seconds. Since the fire detection function of this system can detect within 10 seconds from a distance of about 2 km, it was applicable to forest fires that occur frequently in spring and autumn.

석유화학공장의 소화설비에 대한 고찰

  • 이형섭
    • 방재기술
    • /
    • 통권12호
    • /
    • pp.21-30
    • /
    • 1992
  • This fire fighting systems engineering specification includes the design and installation requirements which normally adopted for petroleum refineries and petrochemical industries. Also, this shall be applied the Korean Fire Safety Law, in addition to the Korean Industry Safety & Health Law and NFPA Code.

  • PDF

태양광 발전 시스템의 화재 위험 감소 방안에 관한 이론적 연구 (Study on Theoretical Research to Reduce Fire Risk of Solar Power System)

  • 박경진;이근출;이봉우
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.219-224
    • /
    • 2020
  • This study is based on the principle of solar power system and fire breakout. The result of the survey indicates that a solar power system is vulnerable to fire due to lack of maintenance after the installation. Currently the national fire safety agency does not have standards and legal provisions for the installation and maintenance of solar power facilities. Therefore, it increases the risk of fire breakouts as well as possibility of electric shock for the firefighters during fire fighting. This results possible damages to the human and equipments. In this study is proposing an automatic fire extinguishing system to reduce the power generation of solar panels during fire breakouts. Also, propose an over load current alarm system and fire prevention measures for fire fighters. The results of this study will be used as basic data for further fire testing of solar power systems.

전등 부하 및 전동기 부하시 전기화재예방 제어장치의 동작 특성에 관한 연구 (A Study on Dynamic Characteristics of Electrical Fire Prevention Control Devices with a lamp and a motor load)

  • 이상호;오홍석
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.255-260
    • /
    • 2002
  • Recently, the occurrences of electrical fire have been suppressed by an earth leakage breaker(ELB), a no fuse breaker(NFB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the ELB to break the circuit in the case of the failure of pressure contacts on connecting points and the momentary short circuit. Therefore, it is require to study the constructive problem of the ELB. In this paper, we have developed the auxiliary control device, electrical fire prevention control device(EFPCD), of the ELB. And we have tested the operation characteristics of the ELB according to the load(R, L) As a result of this experiment, we could prevent the electrical fire due to the spark and the overheat occurring in the failure of pressure contacts on connecting points and the momentary short circuit.

  • PDF