• Title/Summary/Keyword: Fire industry

Search Result 517, Processing Time 0.026 seconds

Study on the Promotion of Recycling of Old Fire Extinguishers (폐 소화기 재활용 촉진 방안에 관한 연구)

  • Jin, Young-Bae;Jung, Myung-won;Oh, Jung-Seok
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.156-163
    • /
    • 2019
  • This study examined the recycling system of a foreign lung excreta system. First, the measures for promoting the recycling of a pulmonary digestive system were as follows. Second, a manual considering specialization, such as the construction of a recycling treatment system of fire extinguishers and the collection, transportation, recycling, publicity, and education of fire extinguishers, were developed. Third, an education and counseling system is needed to overcome the lack of experience and technical support for systematic and safe disposal of pulmonary digestive system. Fourth, to promote the recycling of fire extinguishers in the government and fire extinguisher related organizations, it is necessary to prevent environmental pollution and recycle parts to reduce the waste of resources and improve the fire extinguisher quality by fostering a fire safety industry and policy support.

A Study on the Ignitibility of Wooden Flooring (목질바닥재의 착화특성에 관한 연구)

  • Kim, Hae-Rim;Kim, Young-Tak;Park, Young-Ju;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.397-402
    • /
    • 2008
  • In this study, we analyzed the ignitibility of the wooden floorings used as the finishing materials for interior with the flammability tester and the ignition point tester. Also we analyzed the limit oxygen index(LOI) using the oxygen index tester and the flame resistance of the wooden floorings. We confirmed that all of the samples had a excellent flame resistance. The ignitibility of the floorings were ranked as the material lumber>the strengthening flooring>the veneer board(1)>the veneer board(2).

  • PDF

A Study on Flame and Smoke Detection Method of a Tunnel Fire (터널 화재의 화염 및 연기 검출 기법 연구)

  • Lee, Jeong-Hun;Lee, Byoung-Moo;Han, Dong-Il
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1027-1028
    • /
    • 2008
  • In this paper, we proposed image-processing technique for automatic real-time fire and smoke detection in tunnel fire environment. To minimize false detection of fire in tunnel we used motion information of video sequence. And this makes it possible to detect exact position of event in early stage with detection, test, and verification procedures. In addition, by comparing false detection elimination results of each step, we have proved the validity and efficiency of proposed algorithm.

  • PDF

A Study of the Seismic Design Categories about Fire protection Facilities (소방시설의 내진설계범주에 관한 연구)

  • Lee, Jeong-Kyoon;Hur, Man-Sung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.227-228
    • /
    • 2013
  • 소방시설의 경우 지진 시 건축물의 진동 수준에 따라 2차적으로 지진하중을 받는다. 따라서 소방시설에 직접적인 피해를 입히는 수준보다 작은 지진동에 대하여 내진설계를 수행하는 것은 소방시설 설치비용이 증가하게 되어, 합리적인 수준에 대하여 내진설계를 수행할 필요가 있다. 본 연구에는 다양한 소방시설에 대한 실물 내진실험을 실시하였고, 내진설계범주에 따른 내진설계 적용필요성에 대하여 제안하였다. 실험결과 실제 지진 시 내진설계범주 A와 내진설계범주 B에 대한 건축물의 경우 현재의 소방시설로도 내구성을 가질 수 있다고 판단된다. 내진설계범주 C와 D의 경우는 건축물에 설치된 소방시설의 기능보전을 위해 내진보강 설계가 필요하다.

  • PDF

A Study on the Development of Fire Protection Industry Using Establishment of Network (네트워크 구축을 통한 소방산업 육성에 관한 연구)

  • Shin, Mi-Young;Lee, Hae-Pyeong;Jung, Do-Young
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.564-569
    • /
    • 2009
  • 최근 산업고도화에 따라 경쟁력의 원천이 노동, 자본에서 기술 및 정보로 전환 되어져 기술의 중요성이 부각되어 지고 있고, 도시화로 인한 소방산업의 경제 기대효과가 증대되고 있다. 따라서 국내 소방산업을 고부가가치 산업으로 집중 육성하기 위해서 관련산업 분야의 각 요소 간 네트워킹 즉 연계 협력강화 구축에 의해 생산적인 산업육성 시스템이 구축되어야 한다. 이에 본 연구에서는 국내 소방산업의 타 산업과의 비교를 통한 네트워킹 구축의 필요성과 네트워킹 구축을 통한 소방산업 육성 방안을 제시하고자 한다.

  • PDF

A numerical analysis on the performance of buckling restrained braces at fire-study of the gap filler effect

  • Talebi, Elnaz;Tahir, Mahmood Md.;Zahmatkesh, Farshad;Kueh, Ahmad B.H.
    • Steel and Composite Structures
    • /
    • v.19 no.3
    • /
    • pp.661-678
    • /
    • 2015
  • Buckling Restrained Braces (BRB) have been widely used in the construction industry as they utilize the most desirable properties of both constituent materials, i.e., steel and concrete. They present excellent structural qualities such as high load bearing capacity, ductility, energy-absorption capability and good structural fire behaviour. The effects of size and type of filler material in the existed gap at the steel core-concrete interface as well as the element's cross sectional shape, on BRB's fire resistance capacity was investigated in this paper. A nonlinear sequentially-coupled thermal-stress three-dimensional model was presented and validated by experimental results. Variation of the samples was described by three groups containing, the steel cores with the same cross section areas and equal yield strength but different materials (metal and concrete) and sizes for the gap. Responses in terms of temperature distribution, critical temperature, heating elapsed time and contraction level of BRB element were examined. The study showed that the superior fire performance of BRB was obtained by altering the filler material in the gap from metal to concrete as well as by increasing the size of the gap. Also, cylindrical BRB performed better under fire conditions compared to the rectangular cross section.

Fire Resistant Regulation Status and Activation Plan of Domestic Modular Construction (국내 모듈러 건축의 내화구조 제도 현황 및 활성화 방안)

  • Choi, Yun-Jeong;An, Jae-Hong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.673-680
    • /
    • 2022
  • Modular construction is recognized as a construction method with various advantages, such as shortening the construction duration, achieving quality control through factory production, ease of maintenance, and reduced construction costs due to reduced weight of materials. However, despite efforts by the modular industry and government to activate modular construction, it has rarely been established in the domestic market. Currently, there are technical limitations to the modular construction fire resisting technology applied to general buildings. The lack of access to modular construction fire resistance regulation is considered a major factor. In this study, the current status and problems with modular construction fire resistance regulation, a significant hindrance factor, were considered to activate modular construction. This study is intended to present a direction for institutional improvement in modular construction fire resistance and a direction for research and development.

Problems and Improvement Directions of Fire Protection Designing and Supervising Jobs (소방 설계·감리업의 문제점 및 개선방향에 관한 연구)

  • Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8745-8752
    • /
    • 2015
  • Since many accidents have occurred in Korea in these days, many people have lost their health and have been damaged. The damages caused by fires which occur to many buildings where many people always reside takes a substantial share of the total damages. And since the proportions of the domestic fire protection designing/supervising industries are relatively much disregarded compared to other kinds of work, it is in the situation that there are many cases of serious damages because the fire protection equipment didn't exert the proper functions on fire after a building is constructed since the supervision against the poor construction along with the inadequate design. In order to improve such situations, in case of the design industry, the criteria on registration and workforce placement, the scope of operation, the design documents required when requesting the agreement to the construction permits, the responsibilities and authorities about the jobs of the fire protection facility designers must be improved and, in case of supervising industry, the registration criteria, the operation scope and the kinds, methods, targets and criteria of supervision, the criteria on the additional placement of assistant supervisors, the contents and scope of work must be improved, the PQ system and Public Supervision System must be reviewed and the systems for preventing any poor supervision must be improved in order to pursue the security of the people and their properties at the same level as the other kinds of work by preparing for the firm position and foundation of the fire protection design and supervision.

Measurement of the Device Properties of Fixed Temperature Heat Detectors for the Fire Modeling (화재모델링을 위한 정온식 열감지기의 장치물성 측정)

  • Park, Hee-Won;Cho, Jae-Ho;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • The high predictive performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of Performance-Based fire safety Design (PBD). The main objective of the present study is to measure input information in order to predictive the accurate activation time of fixed temperature heat detectors adopted in Fire Dynamics Simulator (FDS) as a representative fire model. To end this, Fire Detector Evaluator (FDE) which could be measured the device properties of detector was used, and the spot-type fixed temperature heat detectors of two thermistor types and one bimetal type were considered as research objectors. Activation temperature and Response Time Index (RTI) of detectors required for the fire modeling were measured, and then the RTI was measured for ceiling jet flow and vertical jet flow in consideration of the install location of detectors. The results of fire modeling using measured device properties were compared and validated with the experimental results of full-scale compartment fires. It was confirmed that, in result, the numerically predicted activation time of detector showed reasonable agreement with the measured activation time.