• 제목/요약/키워드: Fire ignition

검색결과 520건 처리시간 0.021초

발포 프라스틱의 착화특성 및 연소가스 분석 (Ignition Characteristics and Combustion Gas Analysis of the Plastics Foam)

  • 이근원;김관응
    • 한국안전학회지
    • /
    • 제16권1호
    • /
    • pp.48-52
    • /
    • 2001
  • This study was undertaken to investigate fire risk characteristics of the plastics foam that is used an insulating materials in workplaces. The ignition characteristics and combustion gas of the plastics foam were carried out using the ISO self-Ignition tester, the Cone Calorimeter, and NES combustion analyzer. The experimental materials used were commercial samples and their composition is not disclosed by the manufacturer. As the experimental results, the self-ignition temperature of the plastics foam ranges from $410^{\circ}C$ to $510^{\circ}C$, and the flash-ignition temperature of plastics foam ranges from $370^{\circ}C$ to $450^{\circ}C$. The difference of ignition temperature on density with plastics foam type was smaller since the amount of combustible gas to ignite is not caused enough. The time to ignition of the polyethylene foam in samples of the plastics foam was shorter, and its of polyethylene foam was longer. The concentration of carbon dioxide of the polyethylene foam shows higher in samples of the plastics foam. It is found that the concentration values of carbon monoxide of the plastics foam show very fatality on people during exposure of 30 minutes in fire.

  • PDF

전원주택의 벽난로와 관련된 화재사례의 분석 (A Case Study on Fire Investigation for a Wood-Burning Stove in an Idyllic House)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.119-128
    • /
    • 2015
  • 이 논문에서는 신축 후 약 2년이 경과한 전원주택에서 벽난로 가동 중에 벽난로로 인한 화재가 발생하여 전소된 사례에 대해 법원을 통해 소방서, 경찰서, 화재보험관련 조사기관, 주택을 시공한 건설회사와 벽난로를 시공한 벽난로제조업체로부터 제공받은 자료들을 분석하여 벽난로 옆 벽체의 목재기둥에 남아 있는 저온장기발화의 화재패턴을 근거로 벽난로 옆 벽체의 목재기둥에 벽난로 화실(火室)의 열이 전도되어 화재가 발생하였음을 입증하였다. 그리고 벽난로 옆의 목재기둥이 저온장기발화를 한 이유는 굴뚝에 환기를 위한 공기창을 설치하지 않았기 때문임을 화재시뮬레이션을 통해 입증하였다.

콘덴서의 발화 메커니즘 실험 (A Study of the Ignition Mechanism in Electric Condenser Iksan Firestation)

  • 김상순;이재욱
    • 대한안전경영과학회지
    • /
    • 제23권3호
    • /
    • pp.103-113
    • /
    • 2021
  • As the use of capacitors in electrical appliances and electrical control circuits increases, the related electrical fire is increasing. There are various parts such as resistors, coils, and capacitors that make up an electric circuit. Among them, the ignition of a capacitor with a temporary charging function is closely related to the structural characteristics of the capacitor. Capacitors can explode due to various reasons, and the high heat generated when they explode ignites the inflammable dielectric, which in turn burns the inflammable materials such as the surrounding electric wires and spreads into a fire. In this paper, the ignition mechanism is studied by conducting a reenactment experiment on the various probabilities that can be ignited in an electric capacitor, and the prevention measures to be applied to the fire prevention are presented.

경질 폴리우레탄폼의 착화성 및 열방출특성 연구 (A Study on Ignitability and Heat Release Rate Characteristics of Rigid Polyurethane Foam)

  • 공영건;이두형
    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.117-123
    • /
    • 2003
  • 본 연구에서는 Setchkin 착화성시험장치와 산소소비원리를 이용한 콘칼로리미터를 사용하여 난연처리되지 않은 경질우레탄폼의 착화특성 및 열방출특성 및 플래쉬오버 가능성에 대하여 연구하였다. 연구결과 경질폴리우레탄폼의 유도발화온도(FIT)는 $383^{\circ}C$$390^{\circ}C$, 자연발화온도(SIT)는 $493^{\circ}C$$495^{\circ}C$로 나타났으며 자연발화온도가 유도발화온도에 비해 약 $100^{\circ}C$ 높게 나타났다. 콘칼로리미터실험에서는 착화시간은 heat flux의 크기가 증가할수록 빨라졌으며 동일한 heat flux 크기에서는 밀도가 작을수록 착화시간은 짧게 나타났다. 열방출율은 $50 ㎾\m^2$에서 가장 크게 나타났으며, 최대열방출율의 경우 heat flux의 크기와 밀도가 커질수록 증가하는 경향을 보였다. 착화시간과 열방출율의 관점에서 경질폴리우레탄폼의 화재성능은 가해진 heat flux의 크기와 밀도에 큰 영향을 받는 것으로 나타났으며, Petrella의 제안방법에 의해 플래쉬오버 가능성을 분류한 결과 플래쉬오버 가능성이 큰 것으로 분류되었다.

열선에 의한 파이프라인내의 수소/공기 혼합기의 착화온도 (Ignition Temperature of Hydrogen/Air Mixture by Hot Wire in Pipeline)

  • 김동준
    • 한국화재소방학회논문지
    • /
    • 제28권4호
    • /
    • pp.8-13
    • /
    • 2014
  • 본 연구에서는 수소 네트워크 설비의 안전성 확보를 위한 기초연구로 파이프라인 내부에서의 수소/공기혼합기의 착화온도를 조사하였다. 착화원으로는 순간적으로 고온이 된 후 일정한 온도를 유지하는 열선을 사용하였다. 수소농도와 열선의 온도를 변화시키며 실험한 결과, 수소농도의 감소에 따라 최저착화온도도 감소하는 경향이 확인되었다. 착화를 위한 열선의 최저온도는 수소 농도 10 vol.%에서 가장 낮음이 확인되었다. 이러한 경향은 열선주변의 부력에 의한 영향이라 생각된다. 또한, 혼합기의 습도는 착화온도, 화염온도에 큰 영향을 미치는 않는 것이 확인되었다.

광 방사로부터 점화 위험성 (Ignition Hazard of Flammable Atmospheres by Optical Radiation)

  • 최상원
    • 한국화재조사학회지
    • /
    • 제5권1호
    • /
    • pp.25-28
    • /
    • 2004
  • Since the very first use of optical systems in the process industries there has been a tacit assumption that, because they are not electrical, they do not present an ignition risk when used in flammable atmospheres. This paper describes about an optical ignition mechanism from experimental work carnied out by Sira Safety Services Limited(UK) and whether there is sufficient of an ignition risk for precautions to be advisable when optical systems are used in flammable atmospheres.

  • PDF

전선의 접속부에서 직렬아크에 의한 전기적 및 열적 신호 분석 (Analysis of Electrical and Thermal Signal for Series Arc in Electrical Contact)

  • 김두현;황동규
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.1-7
    • /
    • 2015
  • This paper is aimed to analyze the electrical and thermal signal such as ignition possibility, ignition time, thermal characteristics and arc fault power that are associated with electrical fire in case of the occurrence of series arc at IV wiring used for interior wiring at commercial power source. In order to analyze the signal, series arc was induced by generating the constant vibration through vibrating device in the one phase (R phase) and ignition possibility was analyzed along the condition of current value by adding cotton material to the contact point of wiring. The ignition time is shortened as the electric current value increased, burning time is not associated with current value and the temperature rose up to $740^{\circ}C$ though it was not ignited. It was checked out that the temperature was the energy source enough that can generate the fire related with insulation aging of wiring and the inflammable. The possibility of electrical fire by series arc was shown as more than 12% at 5A, more than 42% at 20A and arc showed 27W at 5A, 180W at 20A. It was confirmed that the possibility of electrical fire exists at the condition as above and the circuit breaker did not operate. This data can be used as the reference value for the investigation of electrical fire or development of the circuit breaker.

ESS (에너지 저장장치) 배터리 화재사례를 통한 감식기법 및 연소 확산방지에 관한 연구 (A Study on the Identification Technique and Prevention of Combustion Diffusion through ESS (Energy Storage System) Battery Fire Case)

  • 이정일
    • 한국재난정보학회 논문집
    • /
    • 제16권2호
    • /
    • pp.383-391
    • /
    • 2020
  • 연구목적 : 에너지 저장실의 외부 화염에 의한 내부자기 점화 및 점화를 식별하고, 과열로 인한 점화와 외부 열원에 의한 점화의 차이를 분석하는 것이다. 연구방법 : 분리막 녹는점 측정, 배터리 외부 수열 실험, 배터리 과충전 실험, 과충전과 외부수열에 의한 연소 시 전극 판 비교분석, 과충전 연소 특징, 외부수열 화재 연소특징, 3.4(전극판 비교)/ 3.5(과충전)/ 3.6(외부수열) 분석 실험을 하였다. 연구결과: 화재 발생 시까지 센서의 위치에 따른 온도 차이가 극심했음으로 기존처럼 한 모듈 당 온도 센서 두 개로는 측정값이 부족해 온도제어를 통한 화재를 사전에 방지할 수 없다고 판단한다. 결론: 단락이 점화원으로 작용하여 혼합가스에 착화돼 가스폭발이 발생하고, 폭발 압력에 의해 전극이 잘게 파손되며, 가루형태의 리튬산화물이 불꽃반응에 의해 폭죽과 유사한 불꽃이 분출되었다.

형태소 분석을 이용한 발화관련 기기의 새로운 입력 키워드 추출 (New Input Keyword Extraction of Equipments Involved in Ignition Using Morphological Analysis)

  • 김은주;최정우;류정우
    • 한국화재소방학회논문지
    • /
    • 제28권2호
    • /
    • pp.91-97
    • /
    • 2014
  • 급변하는 사회에서 기존에는 없었던 새로운 화재 사고가 발생하거나, 또는 과거에는 자주 발생된 화재 사고가 발생하지 않는 경우가 많아지고 있다. 본 논문에서는 화재분류체계를 개선할 때 사용할 수 있는 새로운 명사를 화재조사데이터로부터 추출하는 방법을 제안하였다. 화재조사데이터는 화재 조사관에 의해 작성된 화재사고 관련 데이터이다. 제안한 방법은 기타 소분류에 포함된 화재조사데이터의 제품명과 발화개요를 형태소 분석하여 발화관련 기기의 소분류 범주로 사용할 수 있는 새로운 입력 키워드를 추출하였다. 본 논문에서는 제품명을 분석하여 발화관련 기기 대분류인 농업용장비와 계절용 기기의 새로운 소분류 범주로 "건조기"와 "보일러"를 추출하였다. 또한 발화개요를 분석하여 발화관련 기기 대분류인 상업장비와 영상, 음향기기의 새로운 소분류 범주로 "수족관"과 "모니터"를 추출하였다. 이 네 가지의 새로운 소분류 범주로 화재조사데이터를 재분류하였을 때 총 3,808건 중 14.39%인 548건이 재분류되었다.

수소/공기/희석제 혼합기의 점화지연과 화학반응 특성연구 (Characteristics of Chemical Reaction and Ignition Delay in Hydrogen/Air/Diluent Mixtures)

  • 이동열;이의주
    • 한국안전학회지
    • /
    • 제36권3호
    • /
    • pp.1-6
    • /
    • 2021
  • Hydrogen is considered a cleaner energy source than fossil fuels. As a result, the use of hydrogen in daily life and economic industries is expected to increase. However, the use of hydrogen energy is currently limited because of safety issues. The rate of combustion of the hydrogen mixture is about seven times higher than that of hydrocarbon fuels. The hydrogen mixture is highly flammable and has a low minimum ignition energy. Therefore, it presents considerable risks for fire and explosions in all areas of hydrogen manufacturing, transportation, storage, and use. In this study, the auto-ignition characteristics of hydrogen were investigated numerically for diluted hydrogen mixtures. Auto-ignition temperature, a critical property predicting the fire and explosion risk in hydrogen combustion, was determined in well-stirred reactors. When N2 and CO2 were used to dilute the hydrogen/air mixture, the ignition delay time increased with increasing dilution ratios in both cases. The CO2-diluted mixtures exhibited a longer ignition delay than the N2-diluted mixtures. We also confirmed that lower initial ignition temperatures increased the ignition delay times at 950 K and above. Overall, the auto-ignition characteristics, such as the concentrations of participating species and ignition delay times, were primarily affected by the initial temperature of the mixture.