• 제목/요약/키워드: Fire ignition

검색결과 520건 처리시간 0.024초

A Study on the Flash Point and Spontaneous Ignition Determination of Diethylene Glycol

  • 김정훈;최재욱
    • 한국태양에너지학회 논문집
    • /
    • 제36권2호
    • /
    • pp.73-78
    • /
    • 2016
  • This study investigates the main factors of fire prevention, such as spontaneous ignition and flash point, while using Diehylene Glycol (DEG) as the antifreeze for automobile and industrial machines. Our results show the flash point of $142^{\circ}C$ and the minimum ignition temperature of $388^{\circ}C$ in the range of $130{\mu}{\ell}{\sim}150{\mu}{\ell}$. By increasing temperature to ignite in 1 second, an instantaneous ignition temperature of the sample is $569^{\circ}C$ in the sample amount of $140{\mu}{\ell}$.

참깻묵의 자연발화온도와 활성화 에너지를 통한 화재 및 폭발의 위험성 평가 (Assessment of the Risks of Fire and Explosion through the Spontaneous Ignition Temperature and Activation Energy of Sesame Seed Oil Cakes)

  • 변성호;최유정;유두열;김경수;오재근;문병선;최재욱
    • Korean Chemical Engineering Research
    • /
    • 제59권2호
    • /
    • pp.225-231
    • /
    • 2021
  • 참깻묵은 4류 위험물 중 동식물류로서 기름을 추출하고 생성된 찌꺼기를 보관하는 중에 열이 축적되어 자연발화의 원인에 의해 화재가 발생되고 있다. 참깻묵의 자연발화에 대한 원인을 규명하기 위하여 시료용기의 두께(3 cm, 5 cm, 7 cm 및 14 cm)를 변화시켜 저장량에 따른 자연발화온도를 구한 결과 3 cm의 경우 180 ℃, 5 cm의 경우160 ℃, 7 cm의 경우 145 ℃, 14 cm의 경우 130 ℃를 구하였다. 시료용기의 두께가 두꺼워질수록 발화한계온도는 낮아졌으며, 발화지연시간 및 최고온도에 도달하는 시간이 길어졌다. 또한 발화와 비발화의 평균온도인 발화한계온도에 의한 겉보기 활성화 에너지는 97.10 [kJ/mol]로서 참깻묵의 발화특성을 파악하였다.

방염 처리에 따른 화재지연 효과 연구 (A Study on the Ignition Delay Effect by Flame-Resistance Paint Treatment)

  • 오규형;김황진;이성은
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.111-116
    • /
    • 2009
  • 시중에 유통되는 17종의 방염 도료를 소방법에서 요구하는 성능에 맞게 MDF에 방염처리하여 화재시 발생되는 복사열에 노출시켰을 경우 어느 정도의 화재지연 효과가 있는지를 연구하였다. 복사열의 크기는 콘히터를 이용하여 $10kW/m^2$에서 $30kW/m^2$까지 변화시키며 실험하였다. 착화시간과 착화형태를 측정하였으며 시료 표면의 온도를 측정하였다. 실험 결과 방염도료를 처리한 시료의 착화 임계열유속은 $10kW/m^2$ 였으며 $30kW/m^2$에서는 방염에 의한 착화지연효과가 없음을 확인할 수 있었다. 또한 시료 표면온도가 $400^{\circ}C$ 이상이 되어도 방염에 의한 화재 억재효과를 기대하기 어렵게 됨을 알 수 있었다.

발화열원에 따른 화재발생 특성 분석 (Analysis of Fire Occurrence Characteristics According to Ignition Heat Sources)

  • 이경수;김태형;이재오
    • 한국재난정보학회 논문집
    • /
    • 제18권2호
    • /
    • pp.280-289
    • /
    • 2022
  • 연구목적: 본 연구에서는 발화열원을 작동기기, 담뱃불·라이터불, 불꽃·불티 등 발화열원에 따른 화재 발생의 특징을 알아보고자 하였다. 연구방법: 일원배치 분산분석과 교차분석을 이용하여 발화열원에 따른 발화환경, 화재피해 현황 및 규모, 발화원인과의 차이 검증을 통해 화재발생 특성을 분석하였다. 연구결과: 작동기기에 의해 발생한 화재는 다른 발화열원에 비해 평일에 발생 빈도가 높고, 이재세대수와 이재민 발생이 가장 많아 소방력 동원과 재산피해가 가장 큰 것으로 나타났다. 최초착화물은 전기·전자기기에 의해 발생되었으며, 합성수지에 의해 연소가 확대되는 특징을 보였다. 담뱃불·라이터불에 의해 발생하는 화재는 토·일요일에 화재가 가장 많이 발생되었으며, 소방력 동원보다는 경찰력 동원이 많은 특징을 보였다. 특히, 최초착화물과 연소확대물은 종이·목재·건초에 의해 발생하는 것으로 나타났다. 불꽃·불티에 의해 발생하는 화재는 토·일요일에 화재가 가장 많이 발생되었으며, 최초착화물과 연소확대물은 종이·목재·건초에 의해 발생하는 것으로 나타났다. 특히, 소방서와의 거리가 가장 먼 곳에서 발생하고 있는 특징을 보였다. 모든 발화열원에서의 공통적인 특징은 오후시간대에 화재가 가장 많았으며, 화재유형은 건축구조물화재가 지배적이었고 발화지점만 연소되는 경우가 가장 많은 것으로 나타났다. 결론: 대형 화재가 발생하게 될 확률은 높아지고 있기 때문에 화재 예방 및 피해를 최소화 하기 위해서는 화재 발생 경향을 분석하고 화재발생 요인에 따른 적절한 대비를 해야 한다. 향후 공공데이터를 이용한 화재발생 특성 분석을 위해서는 재난 데이터의 표준화와, 데이터 개방 및 활성화가 필요하다.

전기다리미의 발화원인 판정에 관한 현상학적 고찰 (A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron)

  • 문용수;공하성;이종화
    • 대한안전경영과학회지
    • /
    • 제11권1호
    • /
    • pp.43-49
    • /
    • 2009
  • This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

Burning Characteristics of Wood-based Materials using Cone Calorimeter and Inclined Panel Tests

  • Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권3호
    • /
    • pp.18-25
    • /
    • 2002
  • Research to discuss the fire performance of materials requires tools for measuring their burning characteristics and validated fire growth models to predict fire behavior of the materials under specific tire scenarios using the measured properties as input for the models. In this study, burning characteristics such as time to ignition, weight loss rate, flame spread, heat release rate, total heat evolved, and effective heat of combustion for four types of wood-based materials were evaluated using the cone calorimeter and inclined panel tests. Time to ignition was affected by not only surface condition and specific gravity of the tested materials but also the type and magnitude of heat source. Results of weight loss rate, measured by inclined panel tests, indicated that heat transfer from the contacted flame used as the heat source into the inner part of the specimen was inversely proportional to specific gravity of material. Flame spread was closely related with ignition time at the near part of burning zone. Under constant and severe external heat flux, there was little difference in weight loss rate and total heat evolved between four types of wood-based panels. More applied heat flux caused by longer ignition time induced a higher first peak value of heat release rate. Burning characteristics data measured in this study can be used effectively as input for fire growth models to predict the fire behavior of materials under specific fire scenarios.

퍼지가능성 척도를 이용한 전기화재 원인진단 시스템의 구축 (Construction of Diagnosis System for Electric-fire Causes using Fuzzy Possibility Measure)

  • 김두현;김상철
    • 한국안전학회지
    • /
    • 제7권4호
    • /
    • pp.105-114
    • /
    • 1992
  • This paper presents an study on the knowledge based system for diagnosing the fire causes using the Fuzzy Possibility Measure( FPM ) about the electric-fire ignition. The Ignition values needed for causes diagnosis is computed as FPM for electric-fire ignition based on the internal scale technique that assigns numerically the characteristic difference of facts to the-tin-ear scale. For the convinience of inference, ignition sources are classified into seven types : short, ground fault, leakge of electricity, overcurrent, cord junction overheating, bad Insulation and spark. The system for causes diagnosis of electric-fire is composed of Knowledge Acquisition System, Inference Engine and Man-Machine Interface, The diagnosis system is wrritten in an artificial intelligence langusge “PROLOG” which uses depth-first search and backward chaining schemes in reasoning process.

  • PDF

우드펠릿의 저장량에 따른 발화온도 및 발화유도시간에 관한 연구 (A Study on the Ignition Temperature and Ignition Induction Time According to Storage Amount of Wood Pellets)

  • 김형석;최유정;김정훈;정필훈;최재욱
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.7-14
    • /
    • 2019
  • 우드펠릿은 화력발전소 및 화목 보일러의 연료로 많이 사용되고 있으나 발열량이 높은 우드펠릿을 장기간 보관 시 자연발화의 위험성이 있다. 본 연구에서는 시료 용기의 크기에 따라 유량의 변화에 따른 최소자연발화온도와 발화한계온도를 구하였으며, 발화한계온도를 이용하여 겉보기 활성화 에너지를 측정함으로써 우드펠릿의 발화 특성을 예측하였다. 겉보기 활성화 에너지는 190.224 kJ/mol을 구하였다. 용기에 저장된 시료량이 두꺼워질수록 시료 표면에서 중심까지의 열전달이 어려워 발화유도시간이 긴 것으로 나타났으며, 용기의 크기가 같을 경우 유량의 양이 많아 질수록 자연발화온도는 낮아졌다. 또한 시료용기가 커질수록 자연발화온도는 낮아지고 발화유도시간은 길어지는 것으로 나타났다.

Hydroxy Propyl Methyl Cellulose의 자연발화에 관한 연구 (A Study on Spontaneous Ignition of Hydroxy Propyl Methyl Cellulose)

  • 최재욱;목연수;하동명
    • 한국화재소방학회논문지
    • /
    • 제15권4호
    • /
    • pp.34-40
    • /
    • 2001
  • HPMC의 자연발화는 일정한 주위온도에서 자연발화의 연구와 Godbret-Greenwald가 고안한 전기로에서 운상상태의 최소발화온도를 구하였으며, 시료를 용기에 충전했을 경우 용기의 크기가 클수록 발화한계 온도는 낮아졌으며 겉보기활성화에너지는 Frank-Kamenetskii의 열발화이론으로부터 계산하였고, 운상상태의 발화온도는 21%의 산소농도하에서 최소발화온도를 구하였으며, 산소농도 변화의 실험결과 산소농도 10%에서 발화되지 않았으며 한계산소농도를 구할 수 있었다.

  • PDF

지하주차장 화재 시 스프링클러헤드 작동 여부에 따른 천장 위 단열재의 발화 여부 (Ignition of ceiling insulation depending on working condition of Sprinkler head in underground parking lot fire)

  • 김서영;공하성
    • 문화기술의 융합
    • /
    • 제8권1호
    • /
    • pp.461-468
    • /
    • 2022
  • 이 논문에서는 지하주차장 화재 시 스프링클러 작동 여부에 따른 천장 위 단열재의 착화 여부에 관해 연구하였다. 스프링클러 작동 여부에 따라 동일 지점의 온도변화를 측정할 경우 시나리오 1에서는 화재와 인접한 천장부의 뿜칠재(SP-2)와 천장 단열재(발포 폴리스티렌)의 경계지점의 화재 내부온도는 658.27 ℃로 분석되었으며, 천장 단열재(발포 폴리시티렌)의 발화점인 427 ℃보다 최대 내부온도가 높아 화염이 천장 단열재에 착화되어 화재가 확산하는 것으로 나타났다. 시나리오 2에서는 화재와 인접한 천장부의 뿜칠재(SP-2)와 천장 단열재(발포 폴리스티렌)의 경계지점의 화재 내부온도는 53.10 ℃로 분석되었으며 뿜칠재(SP-2)와 천장 단열재 (발포 폴리스티렌)의 경계지점 최대 내부온도가 발화점 이하가 되어 화염이 천장 단열재에 착화되지 않았다. 이로 인해 스프링클러 작동 여부에 따라 천장 단열재의 점화 가능성을 예측할 수 있었다.