• 제목/요약/키워드: Fire frequency

검색결과 425건 처리시간 0.025초

소방용품의 강제인증을 위한 위험도평가 및 품목분류에 관한 연구 (A Study on Risk Evaluation and Classification of Fire Equipments for Certification)

  • 최기흥
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.7-12
    • /
    • 2009
  • This study focuses on the classification of fire equipments for certification based on the risk evaluation. In general, known statistics on fire equipment-related accidents needs to be used for risk evaluation. When statistics is not available, however, expected frequency and severity of accident for individual equipment can be taken into account in evaluating the related risks. Based on the level of inherent risks, each equipment is then classified into three categories for certification. For equipments that risk evaluation is not possible, characteristics of those products such as reliability are considered for classification. Once classified, each equipment is assigned an appropriate certification module.

도로터널 구조물 내화설계기준 확립방안에 관한 연구 (An Study on Design Guidelines for Structural Fire Resistance of Road Tunnels)

  • 김흥열;신현준;유용호;김형준
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.416-421
    • /
    • 2008
  • A growing number of larger and bigger tunnels are being constructed, along with the continuing enhancement of road design speed, thereby increasing the frequency of vehicles using tunnels. For such reasons, a fire in tunnels may lead to such situations. Gases and heat caused by fires are to be blamed for such disasters, as well as the development of vehicles leads to the construction of large tunnels. Therefore this study is to provide for the safety of public and rescue personnel in the event of a fire within the tunnel system. For these purpose, the tunnel system must be protected from collapse during a specified time period. This study introduced the role of ITA, it is to developed guidelines for techniques and materials to answer these structural requirements and make tunnels and their ancillary structures more resistant to fire damage.

  • PDF

송전용 폴리머 애자에 대한 산불 영향 평가 (The Influence of Forest Fire on the Polymer Insulator for Transmission Lines)

  • 최인혁;이동일;이철호;강병규;이원교;박준호
    • 한국전기전자재료학회논문지
    • /
    • 제20권9호
    • /
    • pp.787-792
    • /
    • 2007
  • To understand the effects of forest fires on polymer insulators for transmission lines, the forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.

Pool 화재의 연소 특성에 관한 연구 (A Study on the Characteristics of Pool Fire)

  • 오규형;나선종;이성은
    • 한국화재소방학회논문지
    • /
    • 제18권3호
    • /
    • pp.39-44
    • /
    • 2004
  • Pool화재의 화염 거동을 알아보기 위하여 산업에서 많이 사용되는 가연성 액체인 아세톤 메탄을 헥산 그리고 헵탄을 직경 50mrn에서 400nun까지의 용기 내에 넣고 연소실험을 하였다. 용기의 재질은 스테인리스와 구리를 사용하였다. 연소시간과 용기 벽면의 온도 및 열유속 등을 측정하였으며 연소 시 화염의 거동은 비디오카메라를 이용하여 촬영하였다. 실험을 통해서 연소속도와 화염의 높이는 용기 직경의 증가와 함께 증가하였으며 화염의 와류 생성 주기는 용기 직경에 반비례하였다. 또한 pool화재의 특성은 액체연료의 물리 화학적 성질과 용기의 재질에 의해서도 영향을 받는 것을 알 수 있었다.

배선에서 전기화재 전조신호 검출을 위한 H/W 및 S/W 구축 (Development of H/W and S/W for Detecting Electrical Fire Precursor Signal on Electrical Wirings)

  • 김성철;김두현
    • 한국안전학회지
    • /
    • 제24권3호
    • /
    • pp.13-18
    • /
    • 2009
  • This paper is purposed to develop DAQ H/W, S/W and DB which can be used in developing electrical fire alarm system or in analyzing electrical fire cause, by detecting and monitoring precursor signals which have high possibility leading to electrical fire on electrical distribution wires. In this paper, developed was DAQ H/W adopting the C8051FXXX CPU which can analyze the measurement signals of current and voltage in electrical distribution wires, other CPU was investigated in view of the best digital sampling rate on the basis of previous researches for electrical fire alarm system. Also, the S/W which can interface with DAQ H/W's communication protocol and can be applied for electrical fire causes analysis, are embodied by LabVIEW. The combined DAQ H/W and S/W could analyze efficiently normal as well as abnormal electrical signals such as RMS value, instantaneous value of current and voltage, frequency signals etc, on the electrical wires. Also, DB system was constructed for recording various analysis results for precursor signals including voltage and current signals. The results by simulator and experiment showed that the suggested scheme with DAQ H/W, S/W and DB in this paper has high usability.

전기철도 전원계통에서의 화재 사고사례 분석 (Analysis of Fire Accidents on Power Line for DC Electric Traction Vehicles)

  • 송재용;조영진;김진표;박남규;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.241-247
    • /
    • 2008
  • This paper describes a cause of fire accidents on power system for DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accidents of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it make progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial frequency overvoltages and/or lightning one. Deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. The power failures, such as line to ground fault would be causative of the fire accidents.

  • PDF

Seismic capacity evaluation of fire-damaged cabinet facility in a nuclear power plant

  • Nahar, Tahmina Tasnim;Rahman, Md Motiur;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1331-1344
    • /
    • 2021
  • This study is to evaluate the seismic capacity of the fire-damaged cabinet facility in a nuclear power plant (NPP). A prototype of an electrical cabinet is modeled using OpenSees for the numerical simulation. To capture the nonlinear behavior of the cabinet, the constitutive law of the material model under the fire environment is considered. The experimental record from the impact hammer test is extracted trough the frequency-domain decomposition (FDD) method, which is used to verify the effectiveness of the numerical model through modal assurance criteria (MAC). Assuming different temperatures, the nonlinear time history analysis is conducted using a set of fifty earthquakes and the seismic outputs are investigated by the fragility analysis. To get a threshold of intensity measure, the Monte Carlo Simulation (MCS) is adopted for uncertainty reduction purposes. Finally, a capacity estimation model has been proposed through the investigation, which will be helpful for the engineer or NPP operator to evaluate the fire-damaged cabinet strength under seismic excitation. This capacity model is presented in terms of the High Confidence of Low Probability of Failure (HCLPF) point. The results are validated by the proper judgment and can be used to analyze the influences of fire on the electrical cabinet.

Application of Deep Learning: A Review for Firefighting

  • Shaikh, Muhammad Khalid
    • International Journal of Computer Science & Network Security
    • /
    • 제22권5호
    • /
    • pp.73-78
    • /
    • 2022
  • The aim of this paper is to investigate the prevalence of Deep Learning in the literature on Fire & Rescue Service. It is found that deep learning techniques are only beginning to benefit the firefighters. The popular areas where deep learning techniques are making an impact are situational awareness, decision making, mental stress, injuries, well-being of the firefighter such as his sudden fall, inability to move and breathlessness, path planning by the firefighters while getting to an fire scene, wayfinding, tracking firefighters, firefighter physical fitness, employment, prediction of firefighter intervention, firefighter operations such as object recognition in smoky areas, firefighter efficacy, smart firefighting using edge computing, firefighting in teams, and firefighter clothing and safety. The techniques that were found applied in firefighting were Deep learning, Traditional K-Means clustering with engineered time and frequency domain features, Convolutional autoencoders, Long Short-Term Memory (LSTM), Deep Neural Networks, Simulation, VR, ANN, Deep Q Learning, Deep learning based on conditional generative adversarial networks, Decision Trees, Kalman Filters, Computational models, Partial Least Squares, Logistic Regression, Random Forest, Edge computing, C5 Decision Tree, Restricted Boltzmann Machine, Reinforcement Learning, and Recurrent LSTM. The literature review is centered on Firefighters/firemen not involved in wildland fires. The focus was also not on the fire itself. It must also be noted that several deep learning techniques such as CNN were mostly used in fire behavior, fire imaging and identification as well. Those papers that deal with fire behavior were also not part of this literature review.

소방활동을 위한 밀폐공간 무선통신 측위성능 평가 (The Evaluation of UWB Wireless Communication Position Determination Function in an Enclosed Space for Fire Fighting)

  • 김동현;김충일
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.117-122
    • /
    • 2017
  • 밀폐된 공간에서 통신인프라가 파괴될 경우, 긴급 유 무선 통신환경을 구축하여 화재진압 및 소방관 위치확인을 통한 보다 안전한 재난대응환경 확보가 필요하다. 본 연구에서는 Ultra-Wide Band (UWB) 무선통신망을 이용하여 밀폐된 실내 통신환경을 구축하기 위해 6가지 실내환경에 대해 단일 UWB 통신모듈에 대한 통신측위 성능평가를 최대 20 m까지 측정하였다. UWB 통신주파수 각 대역별 6개 채널에 대한 실내환경 통신거리 측정 결과, 개방공간(평균 15.5 m, 최대 20 m), 복도(평균 17.33 m, 최대 20 m), 실내집기류 존치 실내(평균 15.3 m, 최대 20 m), 수직계단(평균 4.33 m, 최대 6 m), 방화문 폐쇄 수평공간(평균 6.5 m, 최대 17 m)으로 나타났다. 이중 7번 채널인 6489.6~1081.6 MHz 주파수 대역에서 통신성능과 거리성능이 가장 우수한 것으로 나타났다. 이에 UWB 통신모듈을 20m 간격으로 설치하고 멀티채널을 이용할 경우 밀폐공간에서 통신환경 구축이 가능한 것으로 판단된다.

강원도 화재의 공간적 군집 특성 분석 (Spatial Clustering Analysis of Fire in Gangwon-Do)

  • 배선학
    • 한국지리정보학회지
    • /
    • 제21권3호
    • /
    • pp.93-103
    • /
    • 2018
  • 본 연구의 목적은 장기적인 화재 발생 데이터를 이용하여 연구지역에서의 화재 발생에 대한 공간적인 군집 특성을 분석하는 것이다. 이를 위해 강원도 읍 면 동 단위에서 지난 40년 동안 발생한 화재 자료를 GIS 데이터로 변환하여 공간 분석을 수행하였다. 화재의 공간적인 군집 특성 파악에는 국지적 공간 연관성을 분석하는 방법인 Moran's I, Geary's Ci 그리고 Getis-Ord's Gi*를 활용하였다. 그리고 개별 분석방법이 지니는 장점을 연구 결과에 반영하기 위하여, 각각의 분석에서 도출된 결과를 통합하여 화재의 공간적 분포 특성을 해석하였다. 연구 결과 강원도에서는 화재 발생의 핫스팟 지역이 존재하였으며, 핫스팟 지역 중에서도 인접한 지역에 비하여 상대적으로 높은 화재 발생빈도를 보이는 지역을 확인할 수 있었다. 본 연구의 결과는 연구지역에서의 화재 발생 위험지역 예측과 소방 시설 재배치를 위한 자료로 활용될 수 있다.