• Title/Summary/Keyword: Fire frequency

Search Result 427, Processing Time 0.041 seconds

Smoke Characteristics of a Small Scale Pool Eire (작은 풀화재에서의 연기 특성)

  • Lee Eui-Ju;Ahn Chan-Sol;Shin Hyun-Joon;Oh Kwang-Chul;Lee Uen-Do
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.58-63
    • /
    • 2005
  • Experimental measurements of flames and the product properties were performed for small kerosene pool fires. which is widely used as a fire source of laboratory scale experiments with scaling modeling. The flame length and flickering frequency were investigated for the flame structures, and compared with the theory. Three measurement methods were introduced to clarify the smoke characteristics, i.e. various gas concentrations, smoke density and thermophoretic sampling with transmission electron microscopy (TEM). The yield of carbon dioxide and the consumption of oxygen were proportional to the heat release rate of pool fires, but there is no trend on carbon monoxide emission. Smoke density of turbulent flames was exponentially increased with the heat release rate. The morphology of the soot particle was investigated to address the degree of soot maturing. The results show that the similar smoke morphology between an inverse jet flame and a pool fire exists despite of different combustion controlling mechanisms.

Analysis of Work Postures of Fire Fighters for Prevention of Musculoskeletal Disorders (소방대원들의 근골격계질환 예방을 위한 작업 자세 분석)

  • Roh, Hyo-Lyun;Son, Sung-Min;Oh, Hyun-Soo;Chang, Seong-Rok;Kim, Yong-Jae
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.71-78
    • /
    • 2011
  • The aim of study was to reduce risk factors of musculoskeletal disorders, and prevent it according to evaluation and analysis of its symptoms survey, and work postures which doing much frequently. This study was conducted by 64 firefighters. It was surveyed physical burden levels, distribution of musculoskeletal symptoms, and analized work postures by using ergonomics tools, such as Rapid Entire Body Assesment(REBA), Rapid Upper Lim Assessment(RULA), NIOSH Lifting Equation(NLE). Physical burden levels, and distribution of musculoskeletal symptoms were surveyed according to frequency analysis, and the analysis of above tools were presented figures and scores. The all the results of REBA were that risk level was "High", action level was "Need soon" and the results of RULA were "The results are required detailed survey and immediate improvement" at Require rescue person handling, fire hose, hybraulic rescue equipment, universal axe work postures. The occurrence possibility of musculoskeletal disorders of fire fighters is quite high due to instability postures, excessive physical work and so on. Thus, making various efforts to prevent disorders, and improving working environment is necessary continuously.

A Study on the Rehabilitation Room of Firefighters at Disaster Spot (재난현장 소방공무원의 회복실에 관한 연구)

  • Chae, Jin;Yim, Dong-Kyun
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.116-125
    • /
    • 2020
  • This study intends to provide a model for the establishment of a rehabilitation room for the safety and rehabilitation of firefighters by proposing a basis for the establishment of a firefighter rehabilitation room at disaster sites. To achieve the research objectives, a questionnaire, frequency analysis, and variance analysis were conducted to assess the effectiveness of rehabilitation rooms for firefighters. Based on the results of the research, the policy suggestions for operating an effective rehabilitation room are as follows. An organization of the operation of the rehabilitation room should be established at each firefighting headquarters, and human resources must be secured for the operation of the rehabilitation room. In addition, detailed operating standards such as the operation contents of the rehabilitation room's operation manager and its operator, as well as its operation procedures should be prepared. Additionally, training to improve the rehabilitation room and its understanding is needed.

Analysis of Adult Cardiopulmonary Resuscitation Skill Performed by Emergency Medical Technicians in Fire Department (소방 2급응급구조사의 성인 심폐소생술에 대한 숙련도 분석)

  • 최용철;이창섭;왕순주
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.13-17
    • /
    • 2004
  • Purpose: The purpose of this study is to predict a reasonable direction to design a pertinent educational program in the future by evaluating an adult CPR(Cardiopulmonary Resuscitation) skill performed by EMTs engaged in fire services organization and comparing the CPR success rate of factors as like a duty place and licensed year. Methods: We studied CPR skill by the use of a CPR manikin(Skillmeter Resusci Annie, Laerdal company). The study population consisted of 320 EMTs. Every EMT performed four cycle after investigating the manikin for 2 minutes. We regarded chest compression with 100 times in a minute as the 100% success rate. We analysed the skill of chest compression, ventilation and chest compression times success rate by the records printed in the CPR paper. Results: The average success rate of chest compression was 59.42$\pm$29.26% and ventilation 49.22$\pm$29.65%. The success rate of manual CPR was different between chest compression and ventilation. Also the success rate of chest compression times was high relatively as a 87.32$\pm$9.14%(p=0.000). For the CPR skill, ventilation was lowest as 49.22%. The factors such as duty place and licensed year did not influence the CPR success rate (p>0.001). Conclusion: We could have conclusion that CPR training should be shared more time in ventilation than in chest compression. Also we could reach to a conclusion that it is important to increase the times of CPR training for improving the accuracy of CPR and that the continuing education of CPR training frequency might be more than four times in a year.

A Study on the Improvement of Hazardous Materials Accident Report for Chemical Safety Management (화학물질 안전관리를 위한 위험물 사고 발생보고서 개선연구)

  • Goh, Moon-Soo;Jang, Hyeon-Jun;Seong, Chun-Mo;Lee, Hunggi;Lee, Bong-Woo;Shin, Dong-il
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.1
    • /
    • pp.41-49
    • /
    • 2022
  • Chemicals are widely used throughout society, and usage is expected to increase in the future. As a result, various accidents related to chemicals and dangerous substances are occurring, and the frequency of occurrence is expected to continue to increase. Thus, it is expected that this study will present problems and improvement directions through analysis of each associated agency's accident report and management system, and improve the research input system to increase efficiency in collecting and statistical calculation of chemical and hazardous accident.

A Study on the Safety Consciousness of Elementary Students (초등학생의 안전의식에 관한 연구)

  • Park, Dae-Sung;Lee, Young-Hyun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.87-104
    • /
    • 2004
  • This study selected the fifth and sixth graders of elementary school in Jeollanamdo who can express their opinions of safety consciousness and understand the items of questionnaire as the population. It selected 10 elementary schools under the supervision of Jeonnam Board of Education and sampled 700 students randomly from 2-3 classes in the 5th and the 6th grade. One preliminary survey was conducted to revise and complement the contents and forms of questionnaire with 70 students of a school from Apr. 1 to 6, 2004 and this study was conducted from Apr. 10 to 30, 2004. Data of this study were collected by explaining the purport of study to subjects after obtaining approval of principal and teacher of the school and distributing questionnaires. Total 700 questionnaires were distributed and 681 were collected (97%) and 602 were used for final analysis except 79 lacking responses. The results of this study are as follows. According to demographical characteristics of subjects, 'male' students were 302(50.%) and 'female' students were 300(49.8%) by sex and 'the 5th graders' were 285(47.3%) and 'the 6th graders' were 317(52.7%) in grade distribution. Residents at 'apartment house' were 406(67.4%) in residence type, 'going to school by foot' was 477 students(79.2%), 'high school graduates' were 297(49.3%) in fathers' education, 'high school graduates' were 366 (60.8%) in mothers' education, 'professional and office workers' were 231(38.4%) in fathers' job, 'full-time workers' were 283(47.0%) in mothers' job, and the number of siblings was one except myself in 343 students(57.0%). Respondents on the level of class showing 'good' were 340(56.5%) and those on the degree of adaptation to school life showing 'active' were 349(58.0%). On the characteristics related to safety education, 360(59.8%) responded it was 'very necessary', on the frequency of safety education at school for last one year, 339(56.3%) responded they had 'once or twice', on the frequency of safety education by parents, 279(46.3%) responded they 'often' had it, on the level of safety practice by parents, 347(57.6%) responded they practiced it 'frequently', on the source of knowledge of safety, 223(37.0%) responded they got it from 'parents, siblings and relatives', on the degree of recognizing the need of safety education textbooks, 295(38.5%) responded 'it was needed', on the recognition of necessity of teacher for safety education, 271(45.0%) answered it was very necessary', and on the recognition of qualification of teacher for safety education, 370(61.5%) answered it was 'paramedic'. The mean score of safety consciousness of subjects was 2.72 (SD. 21) of full score 3, having high score over mean score. According to each area, the area showing the highest safety consciousness was safety of fire(2.83), followed by home safety(2.76) and first-aid treatment(2.76), traffic safety(2.71), play and leisure safety(2.66) and school safety(2.56). Items showing statistical differences in the degree of safety consciousness according to demographical characteristics were sex(t=-3.11, p=.002), education(t=2.33, p=.021) and number of siblings(F=3.729, p=.011). In the difference of safety consciousness between both sexes, 'female' students(2.75) showed higher safety consciousness than 'male' students (2.69), and the former also showed higher safety consciousness than the latter in all six areas of school safety, play and leisure safety, traffic safety, fire safety, home safety and first-aid treatment, and there were statistical differences in the areas of play and leisure safety, traffic safety, fire safety and first-aid treatment. According to the differences of safety consciousness by grade, 'the fifth graders'(2.74) showed higher safety consciousness than 'the sixth graders'(2.70) and the former also showed higher safety consciousness than the latter in all six areas of school safety, play and leisure safety, traffic safety, fire safety, home safety and first-aid treatment, and there were statistical differences in the areas of fire safety and home safety. In the safety consciousness by the number of siblings, 'single son or daughter' (2.78) was highest and their safety consciousness was also highest in all six areas of school safety, play and leisure safety, traffic safety, fire safety, home safety and first-aid treatment, and there were statistical differences in the areas of school safety, fire safety and home safety, There were statistically remarkable differences in degree of adaptation to school life (F=15.349, p=.000) and perceived schooling level(F=9.552, p=.000). According to the degree of safety consciousness related to characteristics of safety education, there were statistical differences at the degree of recognizing the need of safety education(F=9.797, p=.000), degree of safety education at school(F=2.595, p=.006), degree of safety education by parents(F=12.709, p=.000), degree of practicing safety by parents(F=17.579, p=.000), source of knowledge of safety education (F=2,715, p=.044), necessity of safety education textbooks(F=3.972, p=.008), need of safety teacher(F=4.137, p=.006) and qualification standard of safety teacher(F=3.016, p=.029).

  • PDF

Control Algorithm Development for an Arc Current Interruption (아크 전류 차단을 위한 제어알고리즘 개발)

  • 반기종;김낙교
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.3
    • /
    • pp.166-172
    • /
    • 2004
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this Paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the low voltage network. This arc Is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional control algorithm does not have the arc current interrupt function. Hence, Control algorithm of arc current is designed for the interruption of arc fault current which has the modified arc characteristics.

Analysis of Serial Arc with DC Current (DC 전류에 의한 직렬 아크 특성 분석)

  • Ban, Gi-Jong;Nam, Moon-Hyun;Kim, Lark-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1700-1701
    • /
    • 2007
  • DC Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, DC arc detection device is designed for the display of DC arc fault current which is occurred in the local electric network with DC Power. This DC arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and low frequency. DC Arc current detection device is designed for the display of arc fault current which has the modified arc characteristics.

  • PDF

Empirical Application for the Urban Disaster Risk Assessment : Fire, Facility and Escape Cases in Cheongju City (도시 재해위험도 평가 모형 연구 - 화재, 시설, 피난위험도 중심의 청주시 사례 -)

  • Hwang, Hee-Yun;Baek, Ki-Young;Park, Byung-Ho;Lee, Man-Hyung;Hwang, Jae-Hoon;Ryu, Eul-Leal;Kim, Tae-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.1 no.2 s.2
    • /
    • pp.123-137
    • /
    • 2001
  • Based on basic characteristics of urban disasters and their data availabilities in Korea, this study provides risk assessment models which are derived from Cheongju examples. In specific, the application models are confined to fire, facility and escape risk survey results in the paper. For the assessment criteria, major independent variables for the categories of fire include both the frequency levels and the amount of damage. And the degree of facility risk assessment is heavily hinged on both the weighted values of key facilities and their weighted rank-sizes. In the same context, the degree of escape risk assessment is hinged on both the weighted values and the amount of the classification of land. From the empirical configuration, this paper presents that the potential figure of fire risk is relatively higher in the built-up areas within the existing Central Business District where accommodates a number of dilapidated housing units and community-supportive facilities. In contrast, the potential figure of facility and escape risk is higher in both old residential areas and the newly-built apartment complex. In short, the CBD and its neighboring residential areas record a high potential figure in terms of total risk, juxtaposing fire, facility and escape risk all together.

  • PDF

An Experimental Study on the Vibration and Fire Resistance of Steel Void Deck Plate Slab for Omega-steel plate (오메가형 강판을 중공체로 사용한 데크플레이트 슬래브의 진동 및 내화에 관한 실험적 연구)

  • Kim, Sang-Seup;Ryu, Deog-Su
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.705-713
    • /
    • 2011
  • This study was conducted to assess the vibration capacity and the fire resistance capacity of a deck plate slab using an omega steel plate as the void deck plate. First, to evaluate the vibration capacity of the deck plate slab after the insertion of the omega steel plate, three 150mm specimens and three 200mm specimens were made using the slab depth as the main variable. Each specimen consisted of an existing deck plate and two specimens, using the topping depth as the variable according to the slab depth. Second, two real-size specimens were made to evaluate the fire resistance capacity. The results of the test showed that the steel-wire-integrated deck plate slab that was inserted in the omega steel plate did not have a vibration problem due to the void deck plate, because the natural frequency was 12.66-14.09 Hz in the vibration test, and each specimen satisfied the appraisal standards for the load capacity, heat block quality, and chloride inhibition for two hours in the fire resistance test. Consequently, the steel-wire-integrated deck plate slab that was inserted in the omega steel plate can be reduced using the concrete volume and can have higher vibration and fire resistance capacities, similar to the existing deck plate.