• 제목/요약/키워드: Fire evacuation

검색결과 689건 처리시간 0.033초

방탈출카페의 성능위주설계에 의한 피난안전성 확대 방안 (Measures to Increase Evacuation Safety through Performance-Based Design of Escape Room Cafes)

  • 이홍상;이재영;공하성
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.95-104
    • /
    • 2023
  • The purpose of this study is to propose measures to increase evacuation safety by calculating the habitable time using a fire and evacuation simulation program for the Room-escape cafe currently in operation, and comparing and analyzing it with the evacuation required time. Assuming a fire due to overheating of electric heaters in use in front of the warehouse, the habitable time was calculated through fire simulation, and the occupant's evacuation time calculated through evacuation simulation according installation of safety facilities, etc. was compared and analyzed with the habitable time. In the case of escape room cafes with safety facilities installed, evacuation safety was satisfied, but in escape room cafes without safety facilities, the evacuation safety was not secure. As a result of analyzing evacuation safety for each scenario based on the ASET analyzed in the fire simulation, it was found that in scenario 1, evacuation safety was secured and everyone successfully evacuated, while in scenario 2, no one succeeded in evacuation. These results can be said to confirm that the installation of safety facilities is very important in business establishments such as escape room cafes, which become enclosed structures when games are started.

초고층 건물의 화재 대피 시뮬레이터 개발에 관한 연구 (A study on the simulator development for fire evacuation of the high-rise buildings)

  • 박양수;임동진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.308-308
    • /
    • 2000
  • In case of fire in the high-rise buildings, the appropriate and safe evacuation plans for the building residents are very important to minimize the number of casualties. Since the evacuation time usually depends on the floor plans of the buildings, the evacuation plans should be considered while the architectural design is done. Conventionally, the calculation of the evacuation time in the case of fire breakout is based on the approximate mathematical equations which are prone to error In this study, the simulator model is developed to help the architectural designers to access the more accurate evacuation time and find out the floor plans which offers the most safe evacuation plans for the residents in case of fire.

  • PDF

주택형화재경보기 작동에 따른 피난안전해석 (The Analysis of Evacuation Safety by Smoke Alarm in Housing Fire)

  • 최영상;전흥균;백열선
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.73-82
    • /
    • 2011
  • 야간의 주택화재는 피난개시의 지연으로 인명피해 위험이 높아지게 된다. 따라서 주택용화재경보기를 설치하여 조기에 화재경보를 해주어 피난개시시간을 단축시킬 때의 피난안전을 해석하였다. 주택을 연구의 대상 건물로 하여 CFAST를 사용해서 화재특성과 화재경보기 작동시간을 분석하였고, 이를 building EXODUS의 위험인자로 사용하여 4인 가족에 대한 피난시뮬레이션을 하였다. 피난개시시간을 다르게 하였을 때 170초에 피난을 개시한 경우 최초 사망자가 발생하였으나 주택용화재경보기작동시간 37.1초를 피난개시시간으로 한 경우는 안전한 피난이 되었다. 해석결과 주택용화재경보기를 설치할 경우 주택화재로부터 인명과 재산피해를 줄이는데 효과가 있다고 판단하였다.

건축물의 피난계획에 관한 기초적 연구 (A Basic Study on the Evacuation Plans of Buildings)

  • 고치원
    • 한국화재소방학회논문지
    • /
    • 제14권4호
    • /
    • pp.1-6
    • /
    • 2000
  • With the "Fire Protection Building Plan" of the Building Center of Japan as a sample, actual evacuation plans used for large scaled and multi-storied buildings are analyzed. Sufficient number of samples were classified into 6 categories. For room evacuation, time to pass through the exit was the most critical point for larger spaces and movement time in the room was the key for smaller evacuation object zone and less number of evacuees. Seen from the location of fire breakout point, it was witnessed that the numbers of crowding at the exits of the fire escape staircase are serious for floor level evacuation. For vertical traffic line, it was actually proved that time to fire escaping floor is problem of higher buildings. It was also proved that special evacuation methods are in practical use in many buildings in japan.

  • PDF

일본건축학회의 화재 시 피난 엘리베이터를 이용한 피난계획 지침안(案)에 대한 조사(II) (A Investigation Study on the Recommendation for the Evacuation Plan using Evacuation Elevator of AIJ (II))

  • 이재원;김동은;서동구;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.316-321
    • /
    • 2008
  • Most elevators worldwide do not have smoke protection, fire protection, and other features necessary for them to be considered as a means of fire evacuation. It is the aim of this study to investigate and analyze the recommendation for the evacuation plan using evacuation elevator of AIJ the aim of this study is to introduce AIJ method for the safety plan using evacuation elevator of high rise building written by working group fire resistant.

  • PDF

화재 대피 시뮬레이터를 이용한 초대형 고층 건물의 화재 대피 계획에 관한 연구 (A study on the planning for fire evacuation of the high-rise buildings using the fire evacuation simulator)

  • 박양수;임동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 D
    • /
    • pp.618-620
    • /
    • 2000
  • In case of fire in the high-rise buildings, the appropriate and safe evacuation plans for the building residents are very important to minimize the number of casualties. Since the evacuation time usually depends on the floor plans of the buildings, the evacuation plans should be considered while the architectural design is done. Conventionally, the calculation of the evacuation time in the case of fire breakout is based on the approximate mathematical equations which are prone to error. In this study, the simulator model is developed to help the architectural designers to access the more accurate evacuation time and find out the floor plans which offers the most safe evacuation plans for the residents in case of fire.

  • PDF

일본건축학회의 화재 시 피난 엘리베이터를 이용한 피난계획 지침안(案)에 대한 조사 (I) (A Investigation Study on the Recommendation for the Evacuation Plan using Evacuation Elevator of AIJ (I))

  • 권영진;윤유혁
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.3-6
    • /
    • 2008
  • Most elevators worldwide do not have smoke protection, fire protection, and other features necessary for them to be considered as a means of fire evacuation. It is the aim of this study to investigate and analyze the recommendation for the evacuation plan using evacuation elevator of AIJ the aim of this study is to introduce AIJ method for the safety plan using evacuation elevator of high rise building written by working group fire resistant.

  • PDF

다중이용시설의 피난방화문에 관한 연구 (Study of evacuation fire doors in multiple facilities)

  • 차종호
    • 한국산학기술학회논문지
    • /
    • 제15권12호
    • /
    • pp.7380-7384
    • /
    • 2014
  • 피난방화문이란 기존에 성능을 인정받은 방화문의 전면에 축광도료를 바르고 손잡이 부근에는 시온도료를 발라 제작한 방화문으로 기존에 방화설비로만 사용되었던 방화문에 피난 및 안전 기능을 추가, 방화문 자체가 피난설비로서의 기능을 겸용하는 설비이다. 피난안전방화문의 휘도는 기존의 유도표지 휘도(60분후 7mcd)이상의 성능으로 한국소방산업기술원의 휘도시험을 통과한 설비로, 화재 시 가시성의 면적이 피난구유도등에 비해 크며 연기의 하강에도 방화문 아랫부분의 방광상태가 관찰되어 피난자들의 피난유효 시간을 연장시켜 줄 것으로 사료된다. 손잡이 부근에 발라져 있는 시온도료는 일정온도에 도달하면($70^{\circ}C$) 색상이 변화 위험경고가 방화문 바탕에 나타나게 되어 화재 시 피난자들이 방화문 손잡이에 입을 수 있는 1차 재해를 예방할 수 있으며, 화재공간에 진입을 하여야 하는 소방관들에게는 역화 가능성을 사전에 인지 안전 사고를 예방하는데 도움을 줄 것으로 판단된다.

FDS를 이용한 실습선 한바다호 화재 및 피난 연구 (A Study on Fire and Evacuation of TrainingShip HANBADA using FDS)

  • 김원욱
    • 수산해양교육연구
    • /
    • 제29권2호
    • /
    • pp.380-385
    • /
    • 2017
  • Maritime accidents caused by a ship include collisions, sinking, stranding and fire etc. This study is intending to consider fire accidents among such diverse marine accidents. It is much likely that various sorts of fires break out because crews are living in a narrow space for long periods of time consequent on the ship's characteristic of sailing on the sea. This study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of cadets based on the collected simulation data by fire size and sort. As a result of the analysis, It was analyzed the Evacuation Allowable Limit Temperature $60^{\circ}C$ and resulted that there is no influence in evacuation by temperature. In case of visibility analysis, it reached to 5m which is the Evacuation Allowable Limit at 117 seconds under the condition of wood fire in 1MW. When there is Kerosene in 1MW, it took 92.4 seconds to reach by 5m which is the Evacuation Allowable Limit. Theoretical evacuation time for the non-tilted ship was 118.8 seconds in 1MW sized fire so it is shown that the most passengers are met the evacuation safety in case of wood fire. However, the majority of passengers could not be ensured the evacuation safety in Kerosene case.

건축물의 화재 시 피난안전성 평가 개선을 위한 시뮬레이션 분석 연구 (A Study on the Analysis of Simulation for Improvement Evacuation Safety Assessment of Building in Fire)

  • 김혜원;김윤성;이병흔;진승현;구인혁;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.107-108
    • /
    • 2020
  • There is a need to analyze various factors in evacuation safety assessment of building in fire. In the current performance based design, evacuation safety assessment in case of fire is being conducted through the simulation as FDS and Pathfinder. However, the location and size of the door, the location of evacuation in the event of a fire are not considered when design. Accordingly, it is difficult to determine the worst case scenario considering the actual fire. Therefore in this study, in this study, we will propose an appropriate evaluation plan through simulation considering the worst-case scenario that may occur in case of fire.

  • PDF