• Title/Summary/Keyword: Fire escape safety

Search Result 118, Processing Time 0.027 seconds

A Study on the Architectural Planning of the Refuge Areas in Geriatric Hospitals Considering Horizontal Evacuation of the Elderly (노인요양병원에서 고령자의 수평 피난을 고려한 대피공간의 건축계획에 관한 연구)

  • Kim, Mijung;Kweon, Jihoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.3
    • /
    • pp.7-15
    • /
    • 2023
  • Purpose: This study was conducted with the aim of presenting spatial planning directions for evacuation spaces based on an analysis of the performance of horizontal evacuation during the early stages of fire incidents in a geriatric hospital. Methods: Based on a review of previous studies, the research model was designed by establishing occupancy conditions, evacuation, and fire scenarios. The analysis model was developed by considering vulnerable areas in terms of evacuation movement and analyzing the results of evacuation performance. Furthermore, the study analyzed the improvement in evacuation performance by arranging refuge areas. Results: The results of the study are as follows. Firstly, vulnerability spots were identified in terms of evacuation performance by schematizing Required Safe Egress Time, Available Safe Egress Time, and their differences. Secondly, the Required Safe Egress Time in the adjacent public spaces along the escape routes of occupants was found to be higher compared to the Available Safe Egress Time. Thirdly, the results of the correlation analysis between the difference in Available Safe Egress Time and Required Safe Egress Time during the early stages of a fire, as well as their constituent factors, demonstrated that user congestion is a more significant factor in compromising evacuation safety than the physical changes in the fire condition. Fourthly, the analysis of evacuation time was conducted by designating refuge areas where occupants can evacuate within a sufficient timeframe. This led to a decrease in the Required Safe Egress Time. Implications: This study is expected to be used as data on the direction of evacuation space planning to improve the evacuation performance of Geriatric Hospital.

Safety Evaluation of Evacuation in a Dormitory Girls' High School based on PAPS (PAPS에 기반한 여자고등학교 기숙사생의 피난 안전성 평가)

  • Jeon, Seung-duk;Kong, Ha-sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.469-481
    • /
    • 2022
  • This study is for increasing evacuation safety by analyzing RSET(the required safe escape time) through the arrangement of personnel by floor and by room while evacuating in a Girls' High School Dormitory. For this study, PAPS(Physical Activity Promotion System) results that have not been studied so far were analyzed and reflected in evacuation simulations on the premise that individual student's physical strength can affect evacuation. Based on the PAPS results, four scenarios were applied. In addition, evacuation simulation using the pathfinder program was conducted in two situations: the evacuation route was assigned or not. Scenario 4 was the fastest at 168.5 seconds of RSET in assigning evacuation routes among scenarios. As a result of this study, the arrangement of students focusing on improving their academic ability and student life guidance excluding student physical strength has problem. In order to solve this problem, it is effective to place C group students(low grade on PAPS) on low floors and A group students(high grade on PAPS) on high floors and to assign evacuation routes in each room. In the future, the following ways need to be more studied. A study on how to increase evacuation safety through practical evacuation training, the way of assessing evacuation safety reflecting the lifestyle and physical strength of girls, the evacuation route assignment according to the fire occurrence point, and the method to secure evacuation routes in the event of a fire near stairs or entrances should be conducted.

Robust Design of Descending Lifeline Using Double Square Linkage Mechanism (이중 4절링크 기구를 이용한 완강기 강건 설계)

  • Park, Jung-Woo;Yun, Seul-Gi;Jung, Geun-Hak;Jung, Min-Hee;Kim, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.6
    • /
    • pp.108-113
    • /
    • 2021
  • Recently, a new concept of a one-touch descending lifeline has been proposed to address the drawbacks of the conventional descending lifeline, which can be easily installed and quickly evacuated in the case of a fire emergency. All separate parts for escape are initially mounted in a box, and the link-type support is spread out of the window by pushing the handle attached to the box. In this study, the proposed double square linkage mechanism was redesigned, and its safety is verified by determining an appropriate moment of inertia of the link through finite element analysis using Abaqus. The shape and assembling method of the reel and speed controller were also modified such that the safety belt was simultaneously unfolded with link-type support. Finally, the feasibility of the proposed one-touch all-in-one descending lifeline was confirmed through fabrication.

A Study on the Effects of an Increase in the Height of Ship's Accommodation Area on Safe Evacuation in Emergency Situation (선박 거주구역의 높이가 피난안전에 미치는 영향에 대한 연구)

  • Kim, Won-Ouk;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.1
    • /
    • pp.69-73
    • /
    • 2011
  • Unlike land fires, Fires on board a ship are not likely to be extinguished by skilled human resources using a variety of fire fighting equipments, but have to be brought under control on board a ship itself despite of difficult task. There are more cases of deaths from suffocation by smoke than from an increased temperature by heat in fires on board ships, because crew fail to secure a sufficient visibility range enough to escape from the scene of a fire or to leave the ship as early as possible. On the assumption that the height of ship's accommodation area increases from 2.0m to 2.3m comparable to the height of apartments on the ground in Korea, behaviors of fire smokes between the cases of 2.0m and 2.3m heights were compared and analyzed. Based on the blue print of the existing Training Ship "Hanbada", a new blueprint with the 30 cm height adjustment was additionally created. FDS (Fire Dynamic Simulator), which was created by the NIST in the United States and is the most widely distributed simulator for fires, was used to conduct a simulation and predict results. The results of simulation on the basis of temperature of $60^{\circ}C$ showed a safe evacuation period of time at the position 10m apart from the scene of a fire to increase by 55.8 seconds, when the height of ship's accommodation area increased from 2.0m to 2.3m. The results of simulation on the basis of visibility range of 6m showed the safe evacuation periods of time at the positions 10m, 20m and 30m apart from the scene of a fire to increase by 27.1 seconds, 109.2 seconds and 73.3 seconds, respectively, as the height of ship's accommodation area increased from 2.0m to 2.3m. This means that crew can escape more safely from a scene of fires on board when the height of ship's accommodation area is increased and equal to the height of living room in a building on land.

A Study on the Motion Analysis of CPR on EMT Who Wearing PPE (4구급대원의 PPE(Personal Protective Equipment)착용 시 CPR 동작분석에 관한 연구)

  • Shin, Dong-min;Chung, Jae-han;Kim, Seung-yong;Hong, Eun-jung;Kim, Kyoung-yong;Han, Yong-taek
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.74-79
    • /
    • 2015
  • The purpose of this study is to find out its effect on changes in the joint angle and the success rate of cardiopulmonary resuscitation by conducting cardiopulmonary resuscitation (CPR) when wearing and not wearing PPE (personal protective equipment) targeting 20 paramedics with more than 5 years of experience. The subjects carried out CPR in 30:2 for 4 minutes and collected images were digitized by Kwon3D XP Software Package(Version 4.0) and then data were obtained. Data, which were collected by analyzing the motion when starting in one cycle, when pressing to the maximum, in the final position (relaxed), were analyzed by using SPSS 18.0. In conclusion, during CPR, the angle of the both shoulder joints was not significant (p>.05) and the angle of the right elbow joint was reduced in all positions and was statistically significant (p<.05) and the angle of the left was significantly reduced in the maximum pressure posture and the final position (p>.05). In the case of the trunk, the angle increased statistically significantly at all stages (p<.01, p<.001). Also, during CPR, the average compression rate was significantly reduced after wearing PPE (p<.05) and average hand escape time by cycle increased statistically significantly (p<.05) but chest compression execution rate at the correct depth did not show any significant difference between the two groups (p>05).

Evaluation of Hazardous Zones by Evacuation Scenario under Disasters on Training Ships (실습선 재난 시 피난 시나리오 별 위험구역 평가)

  • SangJin Lim;YoonHo Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.200-208
    • /
    • 2024
  • The occurrence a fire on a training ship with a large number of people on board can lead to severe casualties. Hence the Seafarers' Act and Safety Life At Sea(SOLAS) emphasizes the importance of the abandon ship drill. Therefore, in this study, the training ship of Mokpo National Maritime University, Segero, which has a large number of people on board, was selected as the target ship and the likelihood and severity of fire accidents on each deck were predicted through the preliminary hazard analysis(PHA) qualitative risk assessment. Additionally, assuming a fire in a high-risk area, a simulation of evacuation time and population density was performed to quantitatively predict the risk. The the total evacuation time was predicted to be the longest at 501s in the meal time scenario, in which the population distribution was concentrated in one area. Depending on the scenario, some decks had relatively high population densities of over 1.4pers/m2, preventing stagnation in the number of evacuees. The results of this study are expected to be used as basic data to develop training scenarios for training ships by quantifying evacuation time and population density according to various evacuation scenarios, and the research can be expanded in the future through comparison of mathematical models and experimental values.

Program for Estimating Service Time for Oxygen Generating Closed-Circuit SCBA -Pilot Study- (산소발생 폐쇄식 SCBA의 서비스 수명 예측 프로그램 -예비연구-)

  • Han, Don-Hee;Kim, Dong Cheon;Kang, Min Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.2
    • /
    • pp.120-130
    • /
    • 2007
  • A oxygen generating closed-circuit SCBA for escape from fire will be newly developed and then a program for estimating service time for it should be required. A SCBA made on an experimental basis consisted of five components such as half facepiece (mask), $KO_2$ box, oxygen reservoir, $CO_2$ remover and hood. The half mask had a good fitting performance since fit factors for 10 subjects were all above 100. It was found that height of subjects should be the best variable to estimate service time. Measured service time was inversely correlated with height of subjects. Service life time could be estimated by interpolation and extrapolation using inverse relationship between height and measured service time, for example, 28 minutes for male and female of 170 cm during resting, 10 minutes at the walk of 4 km/h and 5 minutes at the walk of 6 km/h considering safety margin of 20%. The study implies that program for estimating service time for the SCBA should require subject's height, speed of walk (4 km/h and 6 km/h) and fit testing. Considering safety margin, selecting younger subjects would be better. The study on the number of subjects and selecting facial dimensions should be more needed for the final program.

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

A survey of the Types of Burns in Children and Mother's Preventive Attitudes to, and Knowledge of Burns (어린이 화상사고 유형과 어머니의 예방, 태도, 지식에 대한 실태조사)

  • Han Jung Suk;Kim Dong Hee
    • Child Health Nursing Research
    • /
    • v.4 no.1
    • /
    • pp.97-104
    • /
    • 1998
  • Burns in children result in the loss of precious life, or if the child survives, in much suffering from physical, emotional, social, and economic problems. These burn accidents to children happen in the bustle of family life and frequently without any warning. With this background information, this study was designed to identity types of burns in children and mothers' attitudes towards, and knowledge of burn prevention, in order, to not only, in still a safety consciousness regarding the seriousness of burn accidents and the strengthening prevention, but also as basic data towards the development of an educational program aimed at prevention. From May 1 to May 25 in 1997, data were collected from the mothers of children attending five day care centers and kindergartens located in Seoul, which had been selected for the study. The tools used for the study, which were developed by the researchers, surveyed the type of burns suffered by children, mothers' knowledge of burns and attitudes toward burn accidents. The data were analyzed through real numbers percentages and analysis was done using SPSS computer programs. The results of the study show that the most frequent type of burn accidents were those caused by hot water(55.4%) and these were frequently related to everyday habits that easily lead to danger. Further, the first aid treatment following a burn was weak. The majority of the mothers had not instructed their children on who to contact in the case of a fire, first aid for burns, or how to take escape in the case of a fire. This left the children in a defenseless position in case of a fire. The mothers showed a lack knowledge, on what to do when a blaze is discovered, how to put out a fire, first aid for burns, escaping from a fire and appropriate water temperature, in that 50% of the time they answered incorrectly. From this study a prevention program, HIPP (Home Injury Prevention Program) could be developed that includes fire prevention habits and first aid for burns. This program can be used with kindergarten and elementary school children for group education on fire prevention and can be used as a foundation for construction of a system of facilities and equipment to prevent fires and also prevent injury from fires.

  • PDF

A Comparison of the Trainees' Evacuation Characteristics according to the Indoor Smoke-fullfill during the Safety Training on Ship (선상안전교육 시 선내 연기충진 여부에 따른 실습생의 피난이동특성 비교)

  • Hwang, Kwang-Il;Cho, Ik-Soon;Yun, Gwi-Ho;Kim, Byeol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.4
    • /
    • pp.422-429
    • /
    • 2018
  • To make students recognize the danger of fire smoke that may occur in ships and to improve the response capability, spaces for safety educ ation were built inside the training ship, and scenarios were developed. This study is an analysis of the movement characteristics of the students acquire d under each scenario. Followings are the summary of the analysis results. In the non-smoke environments, there was no difference in the velocity of escape movement between the case of without block on the familiar route and the case of with unexpected block. However, when the indoor was filled with smoke, the visibility became very low because of the smoke density and the average velocity was 62.5 % slower than the case where it was not. Regardless of the scenarios, the average equivalent velocity on the complex path was faster than the simple straight path, and the standard deviation was smaller. Under the smoke-fullfilled environment, although the relative velocity probability distributions of the complex passage and the entire passag e are very similar, the inter-individual fluctuation of the relative velocity ratio of the complex passage to that of the entire passage was very large. On the other hand, equivalent velocity could be expressed by the logarithmic function of the visibility. Also, as the tension of the students increased, the equivalent velocities were accelerated on all scenarios.