The Fire Detection Scheme Utilizing Received Signal Variation (수신 신호 변화를 활용한 화재 감지 기법)

  • Ha, Kyunguk;Kim, Dongwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.251-254
    • /
    • 2018
  • Research about IoT system that utilizes variation of wireless received signal according to the changing of the surrounding environment are actively being studied. In this paper, firstly we proved that the received signal strength changes according to the ambient temperature variation. Then, we proposed the fire detection scheme by using received signal strength variation when the signal exchange between fixed transmitter and receiver periodically. The proposed scheme consists of the received signal strength change detection unit and the internal receiver temperature detection unit which prevents misunderstanding the received signal strength variation by the changing of wireless channel environment as outbreak of fire. The proposed scheme has the advantage of being able to support the existing receiver through software upgrade without additional device.

  • PDF

A Ring-Oriented Multicast Architecture over Mobile Ad Hoc Sensor networks

  • Yang, Yubai;Hong, Choong Seon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.1259-1262
    • /
    • 2004
  • Detecting environmental hazards and monitoring remote terrain are among many sensor network applications. In case of fire detection, it is significantly valuable to monitor fire-spot's shape and trend in time. Mobile ad hoc sensor nodes right round are responsible for sensoring, processing and networking packets, or even launching extinguisher. In this paper, we proposed a ring-oriented Multicast architecture based on "Fisheye State Routing" (MFSR) to organize a group of mobile ad hoc sensor nodes in a multicast way. It is familiar with traditional mesh-based multicast protocol [1] in mobile ad hoc network, trying to concentrates on efficiency and robustness simultaneously. Certain applications-based solution for hazards is proposed, quantitative results including architecture and recovery algorithms of MFSR are also investigated in this paper.

  • PDF

Integrated Logical Model Based on Sensor and Guidance Light Networks for Fire Evacuation (화재 대피 유도를 위한 센서 및 유도등 네트워크 기반의 통합 논리 모델)

  • Boo, Jun-Pil;Kim, Do-Hyeun;Park, Dong-Gook
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.5
    • /
    • pp.109-114
    • /
    • 2009
  • At the present time, buildings are designed higher and more complex than ever before. Therefore the potential disasters are happened such as fire, power outage, earthquake, flood, hurricanes. Their disasters require people inside buildings to be evacuated as soon as possible. This paper presents a new disaster evacuation guidance concept of inner buildings, whiche aims at integrated the constructing of a sensor network and a guidance light networks in order to provide a quick detection of disasters and accurate evacuation guidance based on indoor geo-information, and sends these instructions to people. In this paper, we present the integrated logical model based on sensor and guidance light networks for the fire disaster management in inner building using our concept. And we verify proposed logical model according to experiments with visualization and operations on map.

  • PDF

Introduction of Ultraviolet/Infrared Flame Detector and Method for False Detection Prevention (자외선/적외선 불꽃감지기 소개 및 오동작 방지를 위한 연구)

  • Lim, Byung-Hyun;Ko, Nak-Yong;Hwang, Jong-Sun;Kim, Yeong-Min;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.8-11
    • /
    • 2003
  • We propose that when combustible burn with contain carbon, introduce fire detector with sensor of private-use detectable light energy as infrared and ultraviolet in energy of electromagnetic-wave type radiate from flame, method for correct discrimination to resemble fire produce false alarm of detector such as sun light, hot object radiation, are welding. This research using infrared sensor is pyroelectric infrared sensor based black body radiation theory. Ultraviolet sensor is uv Tron using gas multiplication effect to current discharge and photoelectric effect of metal. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research introduced UV/IR compound type flame detector and proposed method of false alarm reduced to resemble fire. The result propres the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

Research on the Reliability Improvement of Automatic Fire Alarm System (자동화재탐지설비의 신뢰성 개선에 관한 연구)

  • Son, Young-Jin;Lee, Young-Il;Lee, Sang-Hyeon
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.42-49
    • /
    • 2008
  • This research is to provide a scheme for an automatic fire alarm system with higher reliability through solving problems of malfunctioning (false or missing fire alarm) and power interruption (result from frequently unwanted activation, etc) of an automatic fire alarm system. A digital control system with microprocessor-based is proposed to reduce the possibility of malfunctioning through a combinational use of heat, smoke and CO sensors. Higher reliability could be achieved by these multiple sensors based fire detection system and fire distinction algorithm. In this research, we implemented actual fire detection system and conducted fire test to verify improvement on reliability.

Development of Fire-Diagnosis Concrete using Composite Sensors (복합센서를 이용한 화재자현 콘크리트의 개발)

  • Choi, Young-Wha;Kim, Ie-Sung;Park, Kang-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.4
    • /
    • pp.85-92
    • /
    • 2010
  • Use of concrete has undoubtedly become widespread in construction and civil engineering. Sensors are used to add functional characteristics to concrete. Self-diagnosis concrete is also being developed. The thermal protector used in the study is a sensor using the linear expansion and cubical expansion of metal. The LED(Light Emitting Diode) is a phototransistor type, and to secure high-sensitivity light, the prices of these sensors are low. Rising temperatures of concrete elements can be predicted from LED of the external virtual beam due to operation of thermal protector sensors of concrete beam caused by fire load on the concrete specimen. In this study, the development of fire-diagnosis concrete using composite sensors are the fundamental study for damage detection using simply measurements.

  • PDF

Radio Frequency Based Emergency Exit Node Technology

  • Choi, Youngwoo;Kim, Dong Kyoo;Kang, Do Wook;Choi, Wan Sik
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.2 no.1
    • /
    • pp.91-100
    • /
    • 2013
  • This paper introduces an indoor sensor fusion wireless communication device which provides the Location Based Service (LBS) using fire prevention facility. The proposed system can provide information in real time by optimizing the hardware of Wi-Fi technology. The proposed system can be applied to a fire prevention facility (i.e., emergency exit) and provide information such as escape way, emergency exit location, and accident alarm to smart phone users, dedicated terminal holders, or other related organizations including guardians, which makes them respond instantly with lifesaving, emergency mobilization, etc. Also, the proposed system can be used as a composite fire detection sensor node with additional fire and motion detect sensors.

Design and Analysis of Flame Signal Detection with the Combination of UV/IR Sensors (UV/IR센서 결합에 의한 불꽃 영상검출의 설계 및 분석)

  • Kang, Daeseok;Kim, Eunchong;Moon, Piljae;Sin, Wonho;Kang, Min-goo
    • Journal of Internet Computing and Services
    • /
    • v.14 no.2
    • /
    • pp.45-51
    • /
    • 2013
  • In this paper, the combination of ultraviolet and infrared sensors based design for flame signal detection algorithms was proposed with the application of light-wavelength from burning. And, the performance result of image detection was compared by an ultraviolet sensor, an infrared sensor, and the proposed dual-mode sensors(combination of ultraviolet and infrared sensors).

Implementation of the Arc Detection Device Using IR Sensor (IR 센서를 이용한 아크 발생 검출 장치 구현)

  • Hyun, Deuk-Chang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.258-262
    • /
    • 2017
  • Recently energy consumption has been increasing because of advances in the industry, and electrical fires have accounted for 31.9% of all fire accidents. An electrical fire is caused by a short circuit, power surge, or poor contact. Safety devices for short circuits or power surges are currently mandatory and can actually detect problems, but arcing caused by contact failure is difficult to detect in advance. This study used an IR sensor to detect the heat concentration caused by the arc. The data from the low-resolution sensor was amplified as much as four times by interpolation to find the exact location of the heat source and were then investigated.

Performance Improvement of CO Sensor Signal Conditioner for Early Fire Detection System (조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.82-87
    • /
    • 2017
  • This paper presents performance improvement of CO gas sensor signal conditioner for early fire warning system. The warning system is based on the CO sensor and its advanced signal conditioning modules network that employ electochemical gas sensor. The electochemical has advantage of having a linear output and operating with a low consumption and fast response. This electrochemical gas sensor contains a gas membrane and three electrodes(working, counter, reference electrode) in contact with an electrolyte. To use a three-electrode sensor, a voltage has to be applied between the working and the reference electrode according to the specification of the sensor. In this paper, we designed these requirements that should be considered in temperature compensation algorithm and electrode measurement of CO sensor modules by using advanced signal conditioning method included 3-electrode. Simulation and experimental results show that signal conditioner of CO sensor module using 3-electrode have a advantage linearity, sensitivity and stability, fast response etc..