• Title/Summary/Keyword: Fire department connection

Search Result 54, Processing Time 0.023 seconds

Study on Reality of Field Practice and Improvements by Students of Dep. of Emergency Medical Technology (응급구조과 학생 현장실습의 실제와 개선방안 연구)

  • Kwon, Hayrran
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.15-26
    • /
    • 2002
  • As a result of analyzing problems in field practice and its effects, the following conclusions can be obtained. Man students were more satisfied with their choice of this department than woman students and woman students recognized the importance of hospital practice although they felt the need of fire fighting station practice and man students felt the necessity of hospital practice, but they answered the fire fighting station practice was important. Departments of field practice are emergency and nurse departments in hospitals and emergency aid section in fire fighting stations. And it is found that field practice was performed well in relation to major subject. Areas of practice included emergency room, operation room and extensive cure unit and the experience of ambulance was more in fire fighting station than in hospital. Clinical guidance of professor was preferred to once a week and the students answered they felt satisfaction with practice through conference. Answer that field practice was helpful in understanding class was very high as 96.8% and its connection with employment was low as 12.8%. It is found that a proper timing of field practice was winter vacation for hospital practice after completing the second semester of the first year and summer vacation for fire fighting station practice after the first semester of the second year. The most difficult department in field practice was nurse department in hospital because 'respondents were practice students' and administrative department in fire fighting stations because 'they lacked recognition of paramedic'. In making practice diary, 'describing measure results' was difficult most and the respondents wanted to keep the diary in their custody.

  • PDF

A Study on the Seismic Protection Performance of Press Fittings for Light Gauge Stainless Steel Pipes (일반배관용 스테인리스강관에 대한 프레스식 관이음쇠의 내진성능에 관한 연구)

  • Baek, Yeal-Sun;Nam, Jun-Seok
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.65-70
    • /
    • 2017
  • The seismic performance of press fittings is studied, which is one of the weldless joints of stainless steel pipe used in the water piping of recent fire protection system. The piping of this study was constructed based on the piping connection reference of NFPA 13. The permissible displacement of the piping was set as the allowed amount which is given in the Building Structure Standard, and the measurements were repeated 10 times. The Von-mises stress of the piping was 2.48 and 1.25 times of the allowed amount of stress, which was less than the standard, noted three times on the NPPs Allowable Stress for Level D service loading. Therefore, the press fittings shows enough seismic performance.

Examination of the Cause of Damage to Capacitors for Home Appliances and Analysis of the Heat Generation Mechanism (가전용 커패시터의 소손원인 규명 및 발열 메커니즘 해석)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.13-19
    • /
    • 2011
  • The purpose of this study is to examine the cause of damage to electrolytic capacitors and to present the heat generation mechanism in order to prevent the occurrence of similar problems. From the analysis results of electrolytic capacitors collected from accident sites, the fire causing area can be limited to the primary power supply for the initial accident. From the tests performed by applying overvoltage, surge, etc., it is thought that the fuse, varistor, etc., are not directly related to the accidents that occurred. The analysis of the characteristics using a switching regulator showed that the charge and discharge characteristics fell short of standard values. In addition, it is thought that heated electrolytic capacitors caused thermal stress to nearby resistances, elements, etc. It can be seen that the heat generation is governed by the over-ripple current, application of AC overvoltage, surge input, internal temperature increase, defective airtightness, etc. Therefore, when designing an electrolytic capacitor, it is necessary to comprehensively consider the correct polarity arrangement, appropriate voltage application, correct connection of equivalent series resistance(ESR) and equivalent series inductance(SEL), rapid charge and discharge control, sufficient margin of dielectric tangent, etc.

A Connection Management Protocol for Stateful Inspection Firewalls in Multi-Homed Networks

  • Kim, Jin-Ho;Lee, Hee-Jo;Bahk, Sae-Woong
    • Journal of Communications and Networks
    • /
    • v.10 no.4
    • /
    • pp.455-464
    • /
    • 2008
  • To provide network services consistently under various network failures, enterprise networks increasingly utilize path diversity through multi-homing. As a result, multi-homed non-transit autonomous systems become to surpass single-homed networks in number. In this paper, we address an inevitable problem that occurs when networks with multiple entry points deploy firewalls in their borders. The majority of today's firewalls use stateful inspection that exploits connection state for fine-grained control. However, stateful inspection has a topological restriction such that outgoing and incoming traffic of a connection should pass through a single firewall to execute desired packet filtering operation. Multi-homed networking environments suffer from this restriction and BGP policies provide only coarse control over communication paths. Due to these features and the characteristics of datagram routing, there exists a real possibility of asymmetric routing. This mismatch between the exit and entry firewalls for a connection causes connection establishment failures. In this paper, we formulate this phenomenon into a state-sharing problem among multiple fire walls under asymmetric routing condition. To solve this problem, we propose a stateful inspection protocol that requires very low processing and messaging overhead. Our protocol consists of the following two phases: 1) Generation of a TCP SYN cookie marked with the firewall identification number upon a SYN packet arrival, and 2) state sharing triggered by a SYN/ACK packet arrival in the absence of the trail of its initial SYN packet. We demonstrate that our protocol is scalable, robust, and simple enough to be deployed for high speed networks. It also transparently works under any client-server configurations. Last but not least, we present experimental results through a prototype implementation.

Evaluation Index System for Disaster Prevention Signs in Urban Shelters in China

  • Song, Chen;Zhang, Jingxing;Kim, Tae-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.81-85
    • /
    • 2016
  • Reasonable disaster prevention signs play an important role in guiding evacuation. Through the field investigation on disaster prevention signs in shelters and surrounding areas in Beijing, some problems were found in the using of sign system. Based on the principle of integrated design, evacuation and rescue requirements, it is necesssary to make further study on aspects such as, design of function, systematic consideration, humanization design, as well as the internationalization using. This paper presents an evaluation index system for disaster prevention signs. Such a system is very important for strengthening the independent guiding function of sign systems and improving evacuation efficiency. An effective connection could be realized between the internal environment of buildings, evacuation routes, and emergencey shelters.

Performance Evaluation of a Smart CoAP Gateway for Remote Home Safety Services

  • Kim, Hyun-Sik;Seo, Jong-Su;Seo, Jeongwook
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.8
    • /
    • pp.3079-3089
    • /
    • 2015
  • In this paper, a smart constrained application protocol (CoAP)-based gateway with a border router is proposed for home safety services to remotely monitor the trespass, fire, and indoor air quality. The smart CoAP gateway controls a home safety sensor node with a pyroelectric infrared motion sensor, a fire sensor, a humidity and temperature sensor, and a non-dispersive infrared CO2 sensor and gathers sensing data from them. In addition, it can convert physical sensing data into understandable information and perform packet conversion as a border router for seamless connection between a low-power wireless personal area network (6LoWPAN) and the Internet (IPv6). Implementation and laboratory test results verify the feasibility of the smart CoAP gateway which especially can provide about 97.20% data throughput.

Prediction of Poor Contact by Analysis of Electrical Signal and Thermal Characteristics (전기적 신호와 열적특성 분석에 의한 접촉불량 예측)

  • Lee, Heung-Su;Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Yoon-Bok
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.36-41
    • /
    • 2012
  • Electrical Connections often cause fires due to poor contact. Occurrence rate of these fires tends to increase annually. The reason why poor contacts occur is often because it is the low mechanical pressure at the contact points. A typical connection method using mechanical pressure is a screw terminal type. This study reviewed these poor contact cases in the screw terminals. In order to get reproduction of such cases, two types of experiments were conducted. the first one was conducted under the normal contact condition, and the other one was conducted under the poor contact condition that screw terminal of breaker was loosen and did not meet the requirements of toque value. In both types of experiments, compulsory vibration was adopted as a variable to aggravate poor contacts. Each of various current values(4.5A, 9.0A, 13.5A) is input. In these experiments, relationships of a contact, electrical signal such as current and electric pulse by ZCT and thermal characteristics according to vibration effect are analyzed. The suggested data and results in this study provide the useful resources helping to investigate fires due to poor contact, and they develop the detector for poor contact and finally reduce the electrical fire occurrence rate.

Comparison of Sound Pressure Level and Speech Intelligibility of Emergency Broadcasting System at T-junction Corridor Space (T자형 복도 공간의 비상 방송용 확성기 배치별 음압 레벨과 음성 명료도 비교)

  • Jeong, Jeong-Ho;Lee, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.105-112
    • /
    • 2019
  • In this study, an architectural acoustics simulation was conducted to examine the clear and uniform transmission of emergency broadcasting sound in a T junction corridor space. The sound absorption performance of the corridor space and the location and spacing of the loudspeaker for emergency broadcasting were varied. The distribution of the sound pressure level and the distribution of sound transmission indices (STI, RASTI) were compared. The simulation showed that the loudspeaker for emergency broadcasting should be installed approximately 10 m from the center of the T junction corridor connection for clear voice transmission. Narrowing the 25 m installation interval of the NFSC shows that an even clearer and sufficient volume of emergency broadcast sound can be delivered evenly.

Development of the Connection Unit with a Gas Gun Installed in a Quadcopter-type Drone (쿼드콥터형 드론에 설치된 가스총 결합유닛의 개발)

  • Jeon, Junha;Kang, Ki-Jun;Kwon, Hyun-Jin;Chang, Se-Myong;Jeong, Jae-Bok;Baek, Jae-Gu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.9
    • /
    • pp.774-781
    • /
    • 2018
  • In this investigation, a gas gun is proposed driven by carbon dioxide gas and installed on a quadcopter-type small unmanned drone for the purpose of cattle vaccination, and we developed a launcher and its connection unit. The system consists of a commercial drone, a gas gun, a solenoid valve, and the remote communication controller, etc. The velocity of launched projectile is measured, and the full system is finally validated through ground test and flight examination loaded for the real aircraft. The feasibility is checked if this technology is applicable to various disease abatement and hazard mitigation in the fields of agriculture and fire-fighting with the present research and development.

Development of Thermal Precursor DB for Partial Disconnection and Poor Contact on Electrical Wire (배선에서의 반단선 및 접촉불량에 대한 열적 전조 DB구축)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Kang, Dong-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.30-36
    • /
    • 2009
  • This paper aims at the precursor analysis and DB development of electrical fires based on thermal and current signals for partial disconnection and poor contact on electric wires through experiments and simulations. Also, DB system required for developing the precursor DB with these data was studied and designed. Firstly, in case of partial disconnection, characteristics were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF and IV electric wires. Based on the characteristics, About 351 partial disconnection precursor patterns were generated by the thermal analysis for electric wire according to deterioration time under normal state and 200% overload state of rated current. Secondly, in order to develop poor contact precursor patterns, temperature value and the current signal were considered. In simulating the poor contact situation on connector area of MCCB, connection torque was changed. Through the experimental analysis, about 251 poor contact precursor patterns were generated. Finally, Using thermal precursor patterns obtained by partial disconnection and poor contact, electrical fire thermal precursor DB was developed.