• Title/Summary/Keyword: Fire department

Search Result 3,172, Processing Time 0.031 seconds

The Security Service History focused on 1930s in Korea (1930년대에 전개된 경호 활동 고찰)

  • Kim, Eun-Jung
    • Korean Security Journal
    • /
    • no.19
    • /
    • pp.23-41
    • /
    • 2009
  • The purpose of this study is to investigate about security service history on 1930s in Korea. This study used materials by historical facts for the regulations, books and newspapers in 1930s. In 1930s, security service was unknown details of the historical contents so far. There are four parts conclusion of this study: police department of provisional government, security service agency in the provisional government, security service agents of an independence movement, the general society of Korea. Firstly, Korean regional government in Manchuria, which Kokminbu(國民府) organized the security service agency(警護局) for protect government and public security. Most importantly, the security service agency appearanced an important place which were the independence movement and self-governing administration for Koreans in Manchuria. And the security service agency was required by the security service regulations(警護條例) as law. Secondly, diversity activities of security service in police were exposed the duty as 'car escort service(車輛警護)' for offenders, the 'township office guard' from mobsters, 'woodland protect service(林野警護團)' for fire-raisers. security service as police officer were widely application for protection and safety from danger. Thirdly, Mass society was needed to service for public security in daily events such as 'noted singer meeting', 'funeral procession to the graveyard', 'athletic meeting' as private establishment of security service agency in nowadays. people were wanted the private security service(私警護) from 1930s to present. Fourthly, Overseas security service mentioned in attack of politician, protect from poison and security service about train vessel fleet. In 1930s, security service is comprehensive protection which were not only bodyguard, but also safeguard for hazardous materials.

  • PDF

An Improved Movable 3 photomultiplier (3PM)-γ Coincidence Counter Using Logical Sum of Double Coincidences in β-Channel for Activity Standardization

  • Hwang, Han Yull;Lee, Jong Man
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.76-80
    • /
    • 2020
  • Background: To improve the measurement accuracy of liquid-scintillation counting for activity standardization, it is necessary to significantly reduce the background caused by thermal noise or after-pulses. We have therefore improved a movable 3 photomultiplier (3PM)-γ coincidence-counting method using the logical sum of three double coincidences for β events. Materials and Methods: We designed a new data-acquisition system in which β events are obtained by counting the logical sum of three double coincidences. The change in β-detection efficiency can be derived by moving three photomultiplier tubes sequentially from the liquid-scintillation vial. The validity of the method was investigated by activity measurement of 134Cs calibrated at the Korea Research Institute of Standards and Science (KRISS) with 4π(PC)β-γ(NaI(Tl)) coincidence counting using a proportional counter (PC) for the β detector. Results and Discussion: Measurements were taken over 14 counting intervals for each liquidscintillation sample by displacing three photomultiplier tubes up to 45 mm from the sample. The dead time in each β- and γ-counting channel was adjusted to be a non-extending type of 20 ㎲. The background ranged about 1.2-3.3 s-1, such that the contributions of thermal noise or after-pulses were negligible. As the β-detection unit was moved away from the sample, the β-detection efficiencies varied between 0.54 and 0.81. The result obtained by the method at the reference date was 396.3 ± 1.7 kBq/g. This is consistent with the KRISS-certified value of 396.0 ± 2.0 kBq/g within the uncertainty range. Conclusion: The movable 3PM-γ method developed in the present work not only succeeded in reducing background counts to negligible levels but enabled β-detection efficiency to be varied by a geometrical method to apply the efficiency extrapolation method. Compared with our earlier work shown in the study of Hwang et al. [2], the measurement accuracy has much improved. Consequently, the method developed in this study is an improved method suitable for activity standardization of β-γ emitters.

A Study on the Optimal Design of Soft X-ray Ionizer using the Monte Carlo N-Particle Extended Code (Monte Carlo N-Particle Extended 코드를 이용한 연X선 정전기제거장치의 최적설계에 관한 연구)

  • Jeong, Phil hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.34-37
    • /
    • 2017
  • In recent emerging industry, Display field becomes bigger and bigger, and also semiconductor technology becomes high density integration. In Flat Panel Display, there is an issue that electrostatic phenomenon results in fine dust adsorption as electrostatic capacity increases due to bigger size. Destruction of high integrated circuit and pattern deterioration occur in semiconductor and this causes the problem of weakening of thermal resistance. In order to solve this sort of electrostatic failure in this process, Soft X-ray ionizer is mainly used. Soft X-ray Ionizer does not only generate electrical noise and minute particle but also is efficient to remove electrostatic as it has a wide range of ionization. X-ray Generating efficiency has an effect on soft X-ray Ionizer affects neutralizing performance. There exist variable factors such as type of anode, thickness, tube voltage etc., and it takes a lot of time and financial resource to find optimal performance by manufacturing with actual X-ray tube source. MCNPX (Monte Carlo N-Particle Extended) is used for simulation to solve this kind of problem, and optimum efficiency of X-ray generation is anticipated. In this study, X-ray generation efficiency was measured according to target material thickness using MCNPX under the conditions that tube voltage is 5 keV, 10 keV, 15 keV and the target Material is Tungsten(W), Gold(Au), Silver(Ag). At the result, Gold(Au) shows optimum efficiency. In Tube voltage 5 keV, optimal target thickness is $0.05{\mu}m$ and Largest energy of Light flux appears $2.22{\times}10^8$ x-ray flux. In Tube voltage 10 keV, optimal target Thickness is $0.18{\mu}m$ and Largest energy of Light flux appears $1.97{\times}10^9$ x-ray flux. In Tube voltage 15 keV, optimal target Thickness is $0.29{\mu}m$ and Largest energy of Light flux appears $4.59{\times}10^9$ x-ray flux.

A Study on the Turnover Intention of Salespeople in Insurance Distribution Channels (보험유통채널에서 영업사원의 이직의도에 관한 연구)

  • Ryu, Gayeon;Kim, Dong-Hyun;Cha, Jae-Bin
    • Journal of Distribution Science
    • /
    • v.16 no.7
    • /
    • pp.77-86
    • /
    • 2018
  • Purpose - In the insurance distribution channel, the salespeople plays a role of representing the company, and recognizes the needs of the customers and plays a role in responding to them. Therefore, their turnover can have a great influence on the company performance. The purpose of this study is to investigate the structural relationship between salespeople's personal - environmental fit and organizational commitment and turnover intention. Research design, data, and methodology - Data collection was conducted a self-filling questionnaire for salespeople for about one month from July 24, 2017 to August 30, 2017. The subjects of the questionnaire were the insurance salespeople who work in the sales line such as K life, S fire. A total of 450 copies were distributed and 432 copies of the questionnaire were used for final analysis. The analysis program used SPSS 22.0 and AMOS 22.0 programs. Analysis method was Frequency Analysis, Reliability & Confirmatory Factor Analysis, Correlation Analysis and Structural Equation Model(SEM). Results - As a result of Hypothesis 1, Person-Supervisor Fit had significant influence only on Continuance Commitment. Person-Job Fit did not have a significant effect on Organizational Commitment. Person-Coworker Fit had a significant effect on Continuance Commitment and Affective Commitment. Person-Organization Fit had a significant impact on Affective Commitment. Therefore, only , , , , were adopted. As a result of Hypothesis 2, Continuance Commitment had a significant effect on turnover intention. Therefore, only was adopted. Conclusions - This study suggests that it is necessary to manage the human resources in the sales field through studies related to salespeople's extension of the research scope and salespeople's turnover intention. Based on the results of this study, the conclusion suggests some implications for the efficient human resources management of insurance companies in sales channels. It is expected that it will be helpful for the salespeople to find out what kind of Person-Environment Fit affects the organizational commitment and how to manage the organizational commitment among the three dimensions of organizational commitment to reduce turnover intention.

The Study about Improvement of Neuro Energy Decreased by Energy Saving (에너지절감에 의해 감소되는 뉴로에너지의 증강에 관한 연구)

  • Kim, Myung-Ho;Kang, Dong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.715-721
    • /
    • 2018
  • This study examined energy saving and elevating the worker's neuro energy (comfort, concentration, physical, and psychological stability) by compensating for the unpleasant tactile sensation to stimulate auditory and olfactory senses and reduce energy consumption. The experiment was conducted in an environment test room under the test conditions of temperature $25[^{\circ}C]$, relative humidity 50[RH%], illumination 1,000[lux] and air current speed 0.02[m/sec] by stimulating the auditory senses with a 1/f change in rhythm and the olfactory senses with an aroma scent. The experiment utilized the method of EEG, which evaluates human body's psychological status via tactile means, and the method of the vibra image, which evaluates the learning abilities, HRV and human body's psychological status via non-tactile means. The subjects were selected as eight university students (four males and four females) in their 20s, the type that have high relative ${\alpha}$(8~13[Hz]) activation in occipital lobe, which brings the highest level of mind stability and concentration, who had no difficulty in physical activities. The subjects' posture and physical activity was fixed to 1met - when the subjects are seated and relaxing in a comfortable environment - and their clothes condition was standardized as 0.7clo. As a result, the sentimental and psychological stability and concentration were the highest in the multisensory stimulation of jasmine scent and change rhythm of an a=1.106 sound source. In addition, under this condition, the relative $M{\alpha}$ and relative $M{\beta}$ increased by 70.49[%] and 89.72[%], respectively; the HRT decreased by 39.09[%]; and the fatigue and tension/anxiety decreased by 36.85[%] and 15.54[%], respectively.

A Preliminary Study on the Stress Perception and Ways to Cope with Stress for Seafarers (선원들의 스트레스 인지와 그 대처방법에 관한 기초 연구)

  • Seo Young-Seung;Kim Jae-Ho
    • Journal of Navigation and Port Research
    • /
    • v.29 no.1 s.97
    • /
    • pp.35-42
    • /
    • 2005
  • This study aims at analyzing the extent of seafarers' perception on their stress and ways to cope with the stress and providing fundamental data for establishing on the stress management of seafarers. In this paper 428 seafarers, who were in the fire-fighting and survival technique training course in Korea Institute of Maritime and fisheries Technology, were sampled and asked to fill out two kinds of questionnaire. One is a questionnaire on seafarers' stress perception and the other is that on the measure of their coping with stress. The collected data were analyzed by using descriptive statistics, t-test and ANOVA by SPSS 10.1 package. The results of this study are as follow. 1) There were significant differences of stress perception in navigation area, marital status, amount of smoking, frequency of drinking, exercise, sleep pattern, sleeping hours, leisure time, and job satisfaction 2) There were significant differences of method coping with stress in current position, navigation area, age, ship career, level of education, marital status, yearly income, frequency of drinking, amount of drinking, exercise, sleep pattern, and job satisfaction 3) The relation between stress perception and ways of coping with stress showed that the group with higher stress perception tended to use emotion-focused coping style and desirable thinking.

A Study on the Formation and Change in the Mordern Sajik Park (근대 사직공원의 형성과 변천)

  • Kim, Seo-Lin;Kim, Hai-Gyoung;Park, Mi-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.4
    • /
    • pp.120-131
    • /
    • 2014
  • Sajikdan(a sort of national shrine in Korea) built at the time of foundation of Joseon was entrenched into Sajik Park going through Japanese colonial era and recently the efforts to restore it is in progress. The details of change in Sajikdan in terms of diachronic analysis are as follows: Firstly, the first period refers to one prior to Japanese colonial era from the first king (also named as "Taejo" in Korean) of the Joseon Dynasty, during which it secured and strengthened the presence as a place for performing important national rites in a nation. It was built on the foot of Inwangsan Mt. at the time of the first king in Joseon Dynasty at first, was destroyed fully by fire during a Japanese Invasion period to Korea(1592-98) and afterward its ancestral ritual facilities were completed under the regime of Youngjo. However, as Japanese intervention coming to the fore, its place was destroyed and then ancestral rites were also abolished in 1908. Secondly, next period falls on 1910 to 1944 when it was transformed and entrenched into a park by the Japanese Empire. While facilities related to a park and an heterogeneous building around the part of boundary were set up, the area of altar, a ritual house and d door of Sajikdan were also designated as historical remains and treasures. Thirdly, this period refers to one from Korea's liberation year from Japanese colony(1945) to the year of 1984 when it had a mixed placeness with the statues, monuments and buildings with heterogeneous nature built. Furthermore, a door of Sajikdan was removed and reconstructed over twice due to opening of Sajik Tunnel. Fourthly, a final period falls on 1985 to the present when efforts are in progress to restore the historicity and symbolism of Sajikdan. A plan for restoration is promoted but now is a difficult time suffering from troubles caused by residents' resistance. Scrutinized historical researches through excavation investigation and residents' understanding are required altogether for restoration of Sajikdan.

Evaluation on Resource Recovery Potential by Landfill Gas Production (매립가스 발생량에 따른 자원화 가능성 평가)

  • Lee, Hae-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4679-4688
    • /
    • 2011
  • This study was performed to the municipal waste generation amounts and characteristics for B city in Gangwon province, predicted the methane gas generation rate emitted from landfill, and analyzed the possibility of energy recovery to RDF(Refuse Derived Fuel) using combustible waste. The study results showed that the average bulk density of municipal waste for B city was 144.0 kg/$m^3$, and the average ratios of combustible waste were 36.0 % of paper, 21.6 % of vinyl, and 19.7 % of food waste. respectively. In the experiment for heating value, high and low heating value(moisture) was measured to 3,471 $kca{\ell}$/kg and 2,941 $kca{\ell}$/kg, respectively. After the prohibition of burying of food waste in landfill, the heating value of municipal waste was dramatically increased due to increase of the ratio of paper, vinyl, and plastic waste. The prediction results of methane gas generation rate emitted from landfill showed that the gas generation rate is increasing to 2,505.7 CH4 ton/year in 2021. After then, the rate is decreasing gradually. When the RDF facility is installed, the rate is decreasing after peaking at 1,956.9 CH4 ton/year in 2013. The generation rate of LFG emitted from waste landfill of B city was analyzed to 9.92 $m^3$/min, similar to 10.11 $m^3$/min for other city.

Effect of Nozzle Shape and Injection Pressure on Performance of Hybrid Nozzle (노즐 형상 및 분사 압력이 하이브리드 노즐 성능에 미치는 영향 연구)

  • Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.74-79
    • /
    • 2017
  • The fire extinguishing performance of hybrid nozzle systems is improved by injecting an extinguishing agent concentrically into the target site and, in this study, water mist is used as a water curtain to confine the droplets of the agent. In this study, we numerically investigated the effect of the foundation angle and injection pressure on the performance of a hybrid nozzle by evaluating the mean radius of the volume fractions of the agent and water mists. An experiment involving a water mist nozzle was carried out to validate the numerical method and then the droplet behaviors, e.g., stochastic collision, coalescence and breakup, were calculated with 2-way interaction Discrete Particle Modeling (DPM) in the steady state for the hybrid nozzle system. The mean radius of the water mists increased by about 40 %, whereas that of the agent decreased by about 21 %, when the injection pressure was increased from 30 bar to 60 bar. In addition, the mean radius of the agent increased by about 24 % as the foundation angle of the hybrid nozzle head increased from $30^{\circ}$ to $60^{\circ}$. As a result, it can be inferred that the injection angle and pressure are important factors for hybrid water mist designs.

Evaluation of Field Application and Optimum Operational Condition for Heavy Metals Analysis Using Environment-Friendly Bismuth Film Electrode (친환경 비스무스 필름 전극을 이용한 중금속 분석 최적조건 도출 및 현장 적용성 평가)

  • Kim, So-Youn;Yang, Yong-Woon;Jeon, Sook-Lye
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.137-142
    • /
    • 2011
  • This study was conducted to establish the optimal electrolyte and bismuth concentrations using bismuth film electrode in laboratory and to confirm the possibilities of using this operational condition for heavy metals monitoring in field. In lab test, heavy metal measurement was not accurate more than 600 ppb when heavy metal (Pb, Cd, Zn) range 100~1,000 ppb was measured with bismuth 2,000 ppb. So, bismuth and heavy metal was reacted about 1:1 with ASV method. In electrolyte test, 0.1 M acetate buffer (pH 4.5), 0.1 M chloroacetate buffer (pH 2.0), 0.1 M HCl (pH 2.0), 0.1 M $HNO_3$ (pH 2.0) was tested. As a results, 0.1 M acetate buffer was most suitable in ASV measurement with bismuth film electrode. In field application, Pb, Cd and Zn was measured respectively 36~45 ppb, 84~91 ppb, 90~98 ppb when heavy metal (Pb, Cd, Zn) 100 ppb was spiked in field sample. These results were identified of matrix effect in field sample, So relationship between heavy metal measurement and matrix effects will be studied.