• Title/Summary/Keyword: Fire data analysis

Search Result 779, Processing Time 0.028 seconds

Analysis of Electrical and Thermal Signal for Series Arc in Electrical Contact (전선의 접속부에서 직렬아크에 의한 전기적 및 열적 신호 분석)

  • Kim, Doo Hyun;Hwang, Dong Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.1-7
    • /
    • 2015
  • This paper is aimed to analyze the electrical and thermal signal such as ignition possibility, ignition time, thermal characteristics and arc fault power that are associated with electrical fire in case of the occurrence of series arc at IV wiring used for interior wiring at commercial power source. In order to analyze the signal, series arc was induced by generating the constant vibration through vibrating device in the one phase (R phase) and ignition possibility was analyzed along the condition of current value by adding cotton material to the contact point of wiring. The ignition time is shortened as the electric current value increased, burning time is not associated with current value and the temperature rose up to $740^{\circ}C$ though it was not ignited. It was checked out that the temperature was the energy source enough that can generate the fire related with insulation aging of wiring and the inflammable. The possibility of electrical fire by series arc was shown as more than 12% at 5A, more than 42% at 20A and arc showed 27W at 5A, 180W at 20A. It was confirmed that the possibility of electrical fire exists at the condition as above and the circuit breaker did not operate. This data can be used as the reference value for the investigation of electrical fire or development of the circuit breaker.

An Analysis of Emergency Transport Proportional Population (인구비례 응급출동 현황 분석)

  • Kim, Chul-Tae
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.449-456
    • /
    • 2014
  • This study aimed to reveal the statistical correlation between the distribution of jurisdictional population and the incidence of mobilization, which consisted with cases of patient transfer and non-transfer to hospital. For this study, we collected and analysed the data for populational status, area, and cases of patient transfer and non-transfer to hospital from 5 fire stations in D city, from January 2010 to December 2012. Total numbers of mobilization were highest in J fire station and this supreme tendency were also seen in both cases (transfer and non-transfer). On the contrary, those of B fire station were lowest. In case of populational status of specific jurisdiction, S fire station was identified to possess the highest while D fire station showed the lowest. However, influences of jurisdictional population on occurrence of patient transfer and / or non-transfer to hospital were not seemed to be shown.

Study on Predictable Program of Fire.Explosion Accident Using Poisson Distribution Function & Societal Risk Criteria in City Gas (Poisson분포를 이용한 도시가스 화재 폭발사고의 발생 예측프로그램 및 사회적 위험기준에 관한 연구)

  • Ko, Jae-Sun;Kim, Hyo;Lee, Su-Kyoung
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.6-14
    • /
    • 2006
  • The data of city gas accidents has been collected and analysed for not only predictions of the fire and explosion accidents but also the criteria of societal risk. The accidents of the recent 11 years have been broken up into such 3 groups roughly as "release", "explosion", "fire" d 16 groups in detail. Owing to the Poisson probability distribution functions, 'careless work-explosion-pipeline' and 'joint loosening & erosion-release-pipeline' items respectively have turned out to record the lowest and most frequency among the recent 11-years accidents. And thus the proper counteractions must be carried out. In order to assess the societal risks tendency of the fatal gas accidents and set the more obvious safety policies up, the D. O. Hogon equation and the regression method has been used to range the acceptable range in the F-N curve of the cumulative casualties. The further works requires setting up successive database on the fire and explosion accidents systematically to obtain reliable analyses. Also the standard codification will be demanded.

A Study on Application of Combustion Products for Forest Fire Investigation (산불화재 감식을 위한 연소생성물의 응용에 관한 연구)

  • Park, Young-Ju;Lee, Hae-Pyeong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.111-119
    • /
    • 2011
  • This study was designed to provide basic data applicable to fire investigation through consideration of combustion products and propose vulnerability of combustibles through analysis of $CO_2$ emission. In order to achieve these research objectives, characteristics of combustion products such as smoke release rate of each part(raw leaves, branches and barks), $CO_2$ emission and ash production were considered targeting on 6 oak species(Quercus variabilis Blume, Quercus aliena Blume, Quercus serrata, Quercus mongolica Fisch, Quercus dentata Sapling and Quercus acutissima) using cone calorimeter and smoke density tester. As a result, it was found that raw leaves release smoke more relatively than branches and barks, when they burn, and that Quercus variabilis Blume has the highest smoke density. Also, Quercus acutissima released CO and $CO_2$ which are respectively, 6.67 times and 1.43 times more than Quercus variabilis Blume with low $CO_2$ emission. In addition, branches released CO and $CO_2$ more relatively. There was a big difference in ash production among raw leaves(3.1 g), branches(10.5 g) and barks(16.43 g). It was identified that Quercus serrata produces ashes which are nearly 9.95 times more than Quercus variabilis Blume. It demonstrates that Quercus serrata contains relatively higher minerals and that Quercus variabilis Blume can leave lots of traces like stain and carbonization, as it releases smoke a lot and it's difficult to predict visibility, when a forest fire breaks out in its community area. It is also considered that smoke particles containing oil in the air leave strain on the surface of a tree, and that CO and $CO_2$ emission increases, when crown fire to burn branches breaks out.

A Study on the Effective Fire and Smoke Control in Road-Tunnel with Semi-Transverse Ventilation (Oversized Exhaust System) (도로터널 화재시 반횡류식 환기방식에서의 최적배연 연구(대배기구 방식))

  • Kim, Jong-Yoon;Jeon, Yong-Han
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.79-84
    • /
    • 2009
  • The smoke control system plays the most important role in securing evacuation environment when a fire occurs in road tunnels. Smoke control methods in road tunnels are classified into two categories which are longitudinal ventilation system and transverse ventilation system. In this study it is intended to review the characteristics of smoke behavior by performing numerical analysis for calculating the optimal smoke exhaust air volume when a fire occurs in tunnels in which transverse ventilation is applied, and for obtaining the basic data required for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions for various conditions. As a result of this study, when the critical velocity in the tunnel is 1.75m/s and 2.5m/s, the optimal smoke exhaust air volume has to be more than $173m^3/s$, $236m^3/s$ for the distance of the smoke moving which can limit the distance to 250m. In addition, in case of uniform exhaust the generated smoke is effectively taken away if the two exhaust holes near the fire region are opened at the same time.

Spring Forest-Fire Variability over Korea Associated with Large-Scale Climate Factors (대규모 기후인자와 관련된 우리나라 봄철 산불위험도 변동)

  • Jeong, Ji-Yoon;Woo, Sung-Ho;Son, Rack-Hun;Yoon, Jin-Ho;Jeong, Jee-Hoon;Lee, Suk-Jun;Lee, Byung-Doo
    • Atmosphere
    • /
    • v.28 no.4
    • /
    • pp.457-467
    • /
    • 2018
  • This study investigated the variability of spring (March-May) forest fire risk in Korea for the period 1991~2017 and analyzed its relationship with large-scale climate factors. The Forest Weather Index (FWI) representing the meteorological risk for forest fire occurrences calculated based on observational data and its relationship with large-scale climate factors were analyzed. We performed the empirical orthogonal function (EOF) analysis on the spring FWI. The leading EOF mode of FWI accounting for about 70% of total variability was found to be highly correlated with total number of forest fire occurrences in Korea. The high FWI, forest fire occurrence risk, in Korea, is associated with warmer atmosphere temperature in midwest Eurasia-China-Korea peninsula, cyclonic circulation anomaly in northeastern China-Korea peninsula-northwest pacific, westerly wind anomaly in central China-Korea peninsula, and low humidity in Korea. These are further related with warmer sea surface temperature and enhanced outgoing longwave radiation over Western Pacific, which represents a typical condition for a La $Ni\tilde{n}a$ episode. This suggests that large-scale climate factors over East Asia and ENSO could have a significant influence on the occurrence of spring forest fires in Korea.

The Relationship between Job Stress and Career Resilience of Fire Fighting Officers: The Mediation Effect of the Job Efficacy (소방공무원의 직무스트레스와 경력탄력성의 관계: 직무효능감의 매개효과)

  • Han, Hye Kyung;Kim, Gab Sook
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.155-163
    • /
    • 2019
  • The purpose of this study was to investigate the mediation effect of the job efficacy on the relationship between job stress and career resilience of fire fighting officers. The participants of this study were 151 Jeju Island local fire fighting officers. The research tools used were job stress scale, career resilience scale and job efficacy scale. The data were analyzed using the SPSS statistical program. Pearson's correlation analysis, hierarchical multiple regression analysis and the Sobel test were conducted. The results of this study are as follows: First, there was a significant negative correlation between the job stress and the career resilience and between the job stress and the job efficacy, while there was a significant positive correlation between the job efficacy and the career resilience. Second, the job efficacy of fire fighting officers was found to have a perfect mediation effect on the job stress and the career resilience. As a result, it was found that job efficiency as a mediator to cope with job stress can improve the work efficiency by improving the career resilience of fire fighting officers. Finally, the discussion and implication are provided based on the results.

Implementation of Dynamic Context-Awareness Platform for Internet of Things(IoT) Loading Waste Fire-Prevention based on Universal Middleware (유니버설미들웨어기반의 IoT 적재폐기물 화재예방 동적 상황인지 플랫폼 구축)

  • Lee, Hae-Jun;Hwang, Chi-Gon;Yoon, Chang-Pyo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.8
    • /
    • pp.1231-1237
    • /
    • 2022
  • It is necessary to dynamic recognition system with real time loading height and pressure of the loading waste, the drying of wood, batteries, and plastic wastes, which are representative compositional wastes, and the carbonization changes on the surface. The dynamic context awareness service constituted a platform based on Universal Middleware system using BCN convergence communication service as a Ambient SDK model. A context awareness system should be constructed to determine the cause of the fire based on the analysis data of fermentation heat point with natural ignition from the load waste. Furthermore, a real-time dynamic service platform that could be apply to the configuration of scenarios for each type from early warning fire should be built using Universal Middleware. Thus, this issue for Internet of Things realize recognition platform for analyzing low temperature fired fire possibility data should be dynamically configured and presented.

Surface Discharge Characteristics of Phenolic Resin Treated by Heat and Its Structure Analysis (열처리된 페놀수지 표면에서의 방전 특성과 구조분석)

  • Shong, Kil-Mok;Roh, Young-Su;Kwak, Hee-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.71-79
    • /
    • 2006
  • For clearing the cause of firing due to the tacking on the surface of phenolic resin, this paper describes the analysis through a couple of methods ; FT-IR; DTA; photograph analysis, etc. Phenolic resin has been widely employed as a case of low voltage appliances. In the experiment it was confirmed that its surface was carbonized and graphitized by the external fire. In the FT-IR test a graphite specimen thermally treated at $150[^{\circ}C]$ showed the 2 different IR absorption peaks at $1,730[cm^{-1}]\;and\;1,680[cm^{-1}]$. In normal phenolic resin, the exothermic peak appeared at $450[^{\circ}C]$, while in graphite specimen, it appeared at $610[^{\circ}C]$ in DTA test. From the results, the electrical fire causes could be cleared and it is expected to protect the human life and property from the electrical fire by using the important data.

ANALYSIS OF TURBULENT BOUNDARY LAYER OF NATURAL CONVECTION CAUSED BY FIRE ALONG VERTICAL WALL (수직벽 화재 자연대류에 의한 난류 경계층 열유동 특성 해석)

  • Jang, Yong-Jun;Kim, Jin-Ho;Ryu, Ji-Min
    • Journal of computational fluids engineering
    • /
    • v.21 no.4
    • /
    • pp.1-10
    • /
    • 2016
  • The analysis of characteristics of turbulent flow and thermal boundary layer for natural convection caused by fire along vertical wall is performed. The 4m-high vertical copper plate is heated and kept at a uniform surface temperature of $60^{\circ}C$ and the surrounding fluid (air) is kept at $16.5^{\circ}C$. The flow and temperature is solved by large eddy simulation(LES) of FDS code(Ver.6), in which the viscous-sublayer flow is calculated by Werner-Wengle wall function. The whole analyzed domain is assumed as turbulent region to apply wall function even through the laminar flow is transient to the turbulent flow between $10^9$<$Gr_z$<$10^{10}$ in experiments. The various grids from $7{\times}7{\times}128$ to $18{\times}18{\times}128$ are applied to investigate the sensitivity of wall function to $x^+$ value in LES simulation. The mean velocity and temperature profiles in the turbulent boundary layer are compared with experimental data by Tsuji & Nagano and the results from other LES simulation in which the viscous-sublayer flow is directly solved with many grids. The relationship between heat transfer rate($Nu_z$) and $Gr_zPr$ is investigated and calculated heat transfer rates are compared with theoretical equation and experimental data.