• Title/Summary/Keyword: Fire data analysis

Search Result 777, Processing Time 0.03 seconds

Experiments for Combustion Analysis of Hybrid Motor (하이브리드 모터의 연소해석을 위한 실험연구)

  • 하윤호;장선용;이창진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.262-265
    • /
    • 2003
  • This Study is focused on the instrumenting Hybrid Rocket Motor of ACPL at Konkuk University and researching combustion instability by measuring regression rate versus oxidizer mass flux. In the result of experiment, test fire was moderate and we could acquire data of pressure, thrust, and temperature of combustion chamber. In the future, studying unsteady change of regression rate and pressure characteristic analysis of combustion chamber through hundreds of experiments should be performed. furthermore, researching characteristic velocity by taking a measurement of combustion temperature will be inevitable.

  • PDF

Experiments on Performance of Fan used in Pressure Differential System for Smoke Management (급기가압 제연시스템의 송풍기에 대한 실규모 성능평가 실험)

  • Kim, Jung-Yup
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.458-462
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The core technology for development of smoke management system is analysis tool of fan used in pressure differential system. The experiments on performance of sirroco-typed fan are carried out to evaluate the features of fan and present the experimental data for numerical analysis.

  • PDF

Analysis of spray sodium fire phenomena in the containment vessel (격납용기내에서 분무형 나트륨화재 현상 해석)

  • 조병렬;권선길;황성태
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.79-88
    • /
    • 1996
  • A hypothetical accident in the containment vessel of liquid metal reactor could cause a pressure, temperature rise, and a strong aerosol release. The computer codes relating to the modelization of these accident make it necessary to use various input parameter, among which is the dynamic shape factor of aerosols produced. Combustion experiments of sodium spray fire carried out in a closed vessel, which was vertical cylinder made of 1.2m in diameter and 1.8m hight with a volume of 1.7$m^3$. The results of theoretical analysis presented here was compared to data obtained from experiments. The experimental results were summarized as follows. 1) The aerodynamic diameter and geometric diameter of aerosols are decreasing with increasing of injection pressure and injection temperature of sodium 2) The dynamic shape factor of aerosol is proportional to the aerodynamic diameter for a given particle. 3) The correspondence between the aerodynamic diameter and geometric diameter can be as $D_{ae}=0.70 D_{ge}$. 4) Peak pressure rose with increase in pressure and temperature of injection sodium, being more sensitive to the injection pressure than the injection temperature.

  • PDF

A Study on the Unbalanced Current Distribution of HTS Power Cable (초전도 전력케이블의 전류 불평형에 관한 연구)

  • Kim, Jae-Ho;Park, Chung-Hwa
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.43-47
    • /
    • 2012
  • The unbalance currents flow the High Temperature Superconducting (HTS) power cable caused by asymmetrical fault, harmonic distortion and unbalanced load. That problem causes additional loss and leakage field in the HTS power cable, and deteriorates the electric power quality and stability. In addition, large amounts of unbalanced current can cause negative sequence and ground relays to operate. This paper presents an analysis unbalanced three-phase current distribution in HTS power cable caused by unbalanced load condition and grounding methods using PSCAD/EMTDC. The results obtained through the analysis would provide important data for the design of HTS power cables and valid information for their installation in power system.

A Study on the 3D Imaging of High Temperature Heating Cement Paste and the Analysis of Variation of the Pore Structure (고온 가열 시멘트 페이스트의 3D 영상화 및 세공구조 변화 분석에 관한 연구)

  • Kim, Min-Hyouck;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.147-148
    • /
    • 2020
  • In case of high temperature damage such as fire, the durability of concrete is reduced due to the collapse of internal pore tissue. Therefore, in this paper, we are going to analyze the pore structure of cement paste hardening agent using MIP analysis and build up 3D data produced using X-ray CT tomography. The test specimen is made of cement paste from W/C 0.4. As the temperature of heating increased, the amount of air gap and the diameter of air gap in cement paste increased. It is judged that the air gap structure inside cement collapsed due to the evaporation of the hydrate, gel count, capillary water, etc. inside the cement due to the high temperature.

  • PDF

A Study on Fault Detection Monitoring and Diagnosis System of CNG Stations based on Principal Component Analysis(PCA) (주성분분석(PCA) 기법에 기반한 CNG 충전소의 이상감지 모니터링 및 진단 시스템 연구)

  • Lee, Kijun;Lee, Bong Woo;Choi, Dong-Hwang;Kim, Tae-Ok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.53-59
    • /
    • 2014
  • In this study, we suggest a system to build the monitoring model for compressed natural gas (CNG) stations, operated in only non-stationary modes, and perform the real-time monitoring and the abnormality diagnosis using principal component analysis (PCA) that is suitable for processing large amounts of multi-dimensional data among multivariate statistical analysis methods. We build the model by the calculation of the new characteristic variables, called as the major components, finding the factors representing the trend of process operation, or a combination of variables among 7 pressure sensor data and 5 temperature sensor data collected from a CNG station at every second. The real-time monitoring is performed reflecting the data of process operation measured in real-time against the built model. As a result of conducting the test of monitoring in order to improve the accuracy of the system and verification, all data in the normal operation were distinguished as normal. The cause of abnormality could be refined, when abnormality was detected successfully, by tracking the variables out of the score plot.

A Study of Damage Assessment Caused by Hydrogen Gas Leak in Tube Trailer Storage Facilities (수소 Tube Trailer 저장시설에서의 수소가스 누출에 따른 사고피해예측에 관한 연구)

  • Kim, Jong-Rak;Hwang, Seong-Min;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.32-38
    • /
    • 2011
  • As the using rate of an explosive gas has been increased in the industrial site, the regional residents adjacent to the site as well as the site workers have frequently fallen into a dangerous situation. Damage caused by accident in the process using hydrogen gas is not confined only to the relevant process, but also is linked to a large scale of fire or explosion and it bring about heavy casualties. Therefore, personnel in charge should investigate the kinds and causes of the accident, forecast the scale of damage and also, shall establish and manage safety countermeasures. We, in Anti-Calamity Research Center, forecasted the scope of danger if break out a fire or/and explosion in hydrogen gas facilities of MLCC firing process. We selected piping leak accident, which is the most frequent accident case based on an actual analysis of accident data occurred. We select and apply piping leak accident which is the most frequent case based on an actual accident data as a model of damage forecasting scenario caused by accident. A jet fire breaks out if hydrogen gas leaks through pipe size of 10 mm ${\Phi}$ under pressure of 120 bar, and in case of $4kw/m^2$ of radiation level, the radiation heat can produce an effect on up to distance of maximum 12.45 meter. Herein, we are going to recommend safety security and countermeasures for improvement through forecasting of accident damages.

Damage Analysis of the Bridge Structure Caused by Fire Outbreak (화재로 인한 교량구조의 손상 분석)

  • Lee, Hak-Sool;Yang, Sung-Ryong
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.479-492
    • /
    • 2019
  • Purpose: The purpose of this study is to accurately analyze the damage of bridges in order to determine whether fire bridges can be used continuously or to provide information on maintenance augmentation data. Method: XRD, SEM and EDS analyzes of concrete were carried out to estimate the fire temperature transferred to the structure, and analyzed by depth and area from PSCI beam and bottom plate concrete surface. Results: Test results G12,11 for the fire zone concrete were confirmed to be affected by heat up to depth of 60mm and the temperature of the hydrothermal heat was above 1000℃. Also, the girder G10,9,8 was relatively weakly damaged compared to G12,11, and the degree of damage was confirmed to be affected by heat up to a depth of 40 mm. Conclusion: Based on the analyzed data, it is considered that if the repair / reinforcement and periodic inspection are carried out, the bridge can secure sufficient safety even considering the damage caused by the fire.

Assessment of the Combustion Diffusion Pattern and Fire Risk of a Water Purifier Damaged by a General Fire (일반화염에 의해 소손된 정수기의 연소 확산 패턴 및 화재위험성 평가)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.35-39
    • /
    • 2012
  • This paper analyzes the combustion diffusion pattern when a water purifier is artificially ignited outside and inside in order to provide data to examine the cause of fire of a water purifier damaged by fire. The analysis result of the combustion diffusion pattern of a water purifier shows that the combustion diffused at a higher speed when it was ignited inside the purifier than when ignited outside. It took approximately 360 seconds for the water purifier to be half-burned when ignited on the outside, and approximately 180 seconds when ignited from inside. That is, it is thought that the internal combustion speed is higher because the internal ignition causes the generated heat to be accumulated and radiated instantly. It was observed that the water purifier damaged by fire caused by external ignition showed a uniform carbonization pattern and the carbide burned down at the bottom were gradually deposited. The water purifier damaged by internal ignition showed a relatively clear boundary of carbonized surface, which formed a V-pattern. The difference in the combustion patterns presents an objective base from which to determine where the fire started. By the time the purifier was half-burned by fire, the built-in fuse had not melted and the power supply protection device did not operate. In addition, as was found in the case of the fuse damaged by a general fire, carbonization occurred at the metal holder, and it is thought that this fact may be used as a basis from which to determine the cause of a fire.

A Study on the Correlation between Forest Fire Occurrence and Asian Dust during the Spring Season from 2000 to 2008 (2000~2008년 봄철 황사와 산불발생의 관계 분석)

  • Won, Myoung-Soo;Yoon, Suk-Hee;Lee, Woo-Kyun
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.3
    • /
    • pp.148-156
    • /
    • 2011
  • The purpose of this study is to analyze the patterns of forest fire possibly related with Asian dust event and carry out a correlation analysis between forest fire occurrence and existence or not of the Asian dust event during dry seasons i.e. February to May in 2000 to 2008. To study the correlation of forest fire and Asian dust, we surveyed information of Asian dust observations, forest fire statistics, fire danger rating index, weather data such as temperature, relative humidity and wind speed of the day occurring the forest fire. As a consequence of analysis, the regional frequency of Asian dust was the highest in Gyeonggi and Chungbuk divisions. Frequencies of forest fire occurrence by the Asian dust events were the highest in the day before three days of the Asian dust event. The highest frequent regions of forest fire occurrence were district of boundary line between Gyeonggi and Western of Gangwon, Chungbuk and Gyeonbuk inland. The correlation between forest fire and fire danger rating index showed the high correlation with the day before three days and after three days of the Asian dust event. These correlation coefficients were 0.50038 and 0.53978 to 1% significance level. The result of analysis between the frequency of forest fire occurrence and wind speed had a highly negative relationship at all the Asian dust days, the day before and after three days. The correlation coefficients had been -0.58623 to -0.61245 to 1% significance level. Relative humidity showed a little of negative relationship with forest fire occurrence in -0.2568(p ${\leq}$ 0.01) for the Asian dust day and -0.35309(p ${\leq}$ 0.01) for next three days. Moreover, at the day before three days of Asian dust events, it was -0.23701 to 1% significance level. However, the mean temperature did not correlate with frequency of forest fire occurrence by Asian dust events at all.