• Title/Summary/Keyword: Fire data analysis

Search Result 777, Processing Time 0.038 seconds

Mechanical characteristic of ACSR Transmission lines by forest fires (산불에 열화된 ACSR 전선의 기계적 특성 검토)

  • Kang, J.W.;Jang, T.I.;Hong, D.S.;Park, C.G.;Bang, H.K.;Kim, Y.D.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.506-508
    • /
    • 2003
  • In the case of a fire in the mountains, steel wires coated with zinc and aluminum wires of those power cables exposed to the fire or near around will be deteriorated by the blaze and the high temperature. This paper shows the experimental results that apply to a new wire by an artificial flame-maker and results including the intensity of extension and wrench for a conductor. In addition, there's been an experiment and analysis about the mechanical characteristics of the wire of ACSR $480mm^2$ which was removed from A T/L by a forest fire. Then, the database will be made to predict the state of deteriorated wires by a forest fire using those two data, and data necessary to diagnose the life state of an ACSR wire affected by a forest fire will be given.

  • PDF

Optimum Fire Extinguishing Modeling using Impact Factor Analysis on Water Mist System of Pool Fire (영향인자 분석을 통한 고임화재의 미분무수 최적소화 모델링)

  • Hwang, Won-Jun;Kim, Hwang-Jin;Lee, Sung-Eun;Kim, Sung-Won;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.84-89
    • /
    • 2009
  • In this study, the fire extinguishing experiment was performed using a water mist nozzle with variation of factors which affect on the extinguishing time. The variables were distance from nozzle center to fire location, droplet size, height of nozzle and opening or not. With the experimental data, interaction and sensitivity between factors were analysed with Mini tab and deduce a optimum model of fire extinguishing of water mist system. Based on the experiment and modeling of fire extinguishing with water mist system, the most important factor on extinguishing time is the distance from the center of nozzle to fire and the opening effect was small compare with other factors.

Evacuation Safety Evaluation for Apartment Complexes and Officetel under Floors (공동주택 및 오피스텔 지하층에 대한 피난 안전성 평가)

  • Hyeon-gwon Kang;Yong-Han Jeon
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.67-72
    • /
    • 2023
  • Human and material damage can be reduced if the risk is evaluated by engineering analysis of fire combustion products, smoke concentration, and smoke movement speed in the event of a fire in apartment houses and officetels. In this study, a lot of research on related safety evaluation in the basement needs to be studied and reflected in design, so experimental research was conducted to analyze the flow of smoke through computer simulation and provide analysis data through evacuation safety evaluation. First of all, the five-story underground parking lot subject to simulation has a large floor area, which is advantageous for improving evacuation safety performance, but it uses temperature detectors to increase detection time and fire spread speed. Second, it was analyzed that the evacuation time at all evacuation ports did not exceed the evacuation time, and as the time from the start of evacuation to the evacuation time was 216.9% compared to the travel time, it was evaluated that the safety performance of the evacuation was secured. Third, the above simulation results are a comprehensive safety evaluation based on the non-operation of fire extinguishing facilities in the fire room to increase safety, which means that smoother evacuation safety performance can be secured by linking fire extinguishing facilities.

A Study on Intelligent Technique for Correlation Application of Overcurrent and Leakage Current Signals in the Indoor Wiring (옥내배선에서 과전류와 누전 신호의 상관관계 적용을 위한 지능형 기법 연구)

  • Kim, Doo-Hyun;Kim, Eun-Jin;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.14-19
    • /
    • 2015
  • The purpose of this paper is to study the correlation application that electrical fire causes occurs for overcurrent and leakage current signals in the indoor wiring. In the order to purpose, the causes data of overcurrent, or leakage current of electrical fire are drawn out referring to past studies, consulting with experts and experimental data. The correlation application was then applied with fuzzy logic of intelligent technique. To check the reliability and performance of the correlation application, modified center of area(CoA) was adopted to calculate the possibility that electrical fire occurs, whose value was then compared to the results. The chance of electrical fire calculated is higher when two causes of fire are put into the CoA of the correlation application of this paper than that of when each cause is separately put into the CoA. The correlation application developed in this study enables better analysis on possible electrical fire due to overcurrent, or leakage current and provides managers with the possibility of electrical fire so that they can better manage at a time of overcurrent, or leakage current.

A Sensor Module Overcoming Thick Smoke through Investigation of Fire Characteristics (화재 특성 고찰을 통한 농연 극복 센서 모듈)

  • Cho, Min-Young;Shin, Dong-In;Jun, Sewoong
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.4
    • /
    • pp.237-247
    • /
    • 2018
  • In this paper, we describe a sensor module that monitors fire environment by analyzing fire characteristics. We analyzed the smoke characteristics of indoor fire. Six different environments were defined according to the type of smoke and the flame, and the sensors available for each environment were combined. Based on this analysis, the sensors were selected from the perspective of firefighter. The sensor module consists of an RGB camera, an infrared camera and a radar. It is designed with minimum weight to fit on the robot. the enclosure of sensor is designed to protect against the radiant heat of the fire scene. We propose a single camera mode, thermal stereo mode, data fusion mode, and radar mode that can be used depending on the fire scene. Thermal stereo was effectively refined using an image segmentation algorithm, SLIC (Simple Linear Iterative Clustering). In order to reproduce the fire scene, three fire test environments were built and each sensor was verified.

Spatial Econometrics Analysis of Fire Occurrence According to Type of Facilities (시설물 유형에 따른 화재 발생의 공간 계량 분석)

  • Seo, Min Song;Yoo, Hwan Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.3
    • /
    • pp.129-141
    • /
    • 2019
  • In recent years, fast growing cities in Korea are showing signs of being vulnerable to more disasters as their population and facilities increase and intensify. In particular, fire is one of the most common disasters in Korea's cities, along with traffic accidents. Therefore, in this study, we analyze what type of factors affect the fire that threatens urban people. Fire data were acquired for 10 years, from 2007 to 2017, in Jinju, Korea. Spatial distribution pattern of fire occurrence in Jinju was assessed through the spatial autocorrelation analysis. First, spatial autocorrelation analysis was carried out to grasp the spatial distribution pattern of fire occurrence in Jinju city. In addition, correlation and multiple regression analysis were used to confirm spatial dependency and abnormality among factors. Based on this, OLS (Ordinary Least Square) regression analysis was performed using space weighting considering fire location and spatial location of each facility. As a result, First, LISA (Local Indicator of Spatial Association) analysis of the occurrence of fire in Jinju shows that the most central commercial area are fire department, industrial area, and residential area. Second, the OLS regression model was analyzed by applying spatial weighting, focusing on the most derived factors of multiple regression analysis, by integrating population and social variables and physical variables. As a result, the second kind of neighborhood living facility showed the highest correlation with the fire occurrence, followed by the following in the order of single house, sales facility, first type of neighborhood living facility, and number of households. The results of this study are expected to be useful for analyzing the fire occurrence factors of each facility in urban areas and establishing fire safety measures.

An Analytic Method for the Residual Strength Evaluation of Fire-Damaged Reinforced Concrete Beam

  • Park, Won-jun;Park, Ki-bong;Lee, Han-seung
    • Architectural research
    • /
    • v.10 no.2
    • /
    • pp.37-42
    • /
    • 2008
  • This study is to get the proper evaluation of the residual property of reinforced concrete beam exposed to fire. This study focused on the strength resistance and analytical evaluation of RC members exposed high temperature. And this study is the basis analytical research to conduct the other studies. To analysis by the finite element method, the Total-RC program was used to analysis it and the Total-Temp program was also used to analysis the temperature distributions at the section. All of results were compared with the pre-existing experimental data of simple supported beam. Using it, the parameters influencing the structural capacity of the high temperature-damaged RC members and residual strength estimation are investigated. The temperature distribution and the structural capacity at the section are calculated in this step. An application of this method is compared with the heating test result and residual property test for simple supported beam which is subjected to ISO 834 test fire. The results of this study are as follows; 1) The loads-displacement relationship of RC beam, considering initial thermal stress of cross section and heat transfer analysis are estimated comparing analytical value with pre-existing experimental results. 2) by the heating time (0, 1, 2 hours), the results of analysis with parameters show that the load capacity exposing at fire is affected.

The Analysis of Distribution and Characteristics of Forest Fires Damage over 30 ha in Korea (우리나라 30 ha 이상 산불피해의 분포 및 특성 분석)

  • Lee, Hyung-Seok;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.39-46
    • /
    • 2011
  • In order to consider the prevention countermeasure to the occurrence of forest fires, analysing characteristic of the past forest fire data is needed. This research analyzed distribution and characteristics of forest fires damage over 30 ha based on statistics data of forest fires in Korea between 1975 and 2010. As a result, the number of forest fires damage over 30 ha as 23 was most occurred in 1978. Forest fires show an upward tendency from 1970 to 2000. Forest fires of 30 ha~50 ha damaged area was most occurred. Forest fire in Gangwon province was occurred as the number of total 66 (37.0 %). Gangwon province was superior in point density analysis. The number of forest fire occurrence over 30 ha was most high to 114 (63.0 %) in April and to 44 (24.3 %) in Sunday. The occurrence number of forest fire and damage caused by forest fire is increasing more and more since 1975, appropriate authorities can use effectively in devising policy for forest fire prevention from this result.

A Study on the Analysis of Operation Reliability of Fire Doors and Fire Shutters Using Fire Statistical Data (화재통계자료를 활용한 방화문, 방화셔터 작동신뢰성 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.119-120
    • /
    • 2020
  • In order to establish an evaluation method that can quantitatively evaluate the fire safety of existing buildings in Korea, a stochastic approach is needed to consider the extent of damage in the event of actual fire, along with the operation and installation of facilities. Accordingly, as a basic study for the establishment of fire safety assessment methods for buildings, this study aims to analyze the results of safety inspection and the degree of damage caused by the operation of fire doors and fire shutters in order to derive the reliability of fire doors and fire shutters. As a result, the results of inspection of fire shutters and fire doors and the results of operation using fire statisticians are as follows. As a result of the inspection, the positive rate of fire doors was about 82% and 98% of normal operation was derived from the fire investigation.

  • PDF

A Study on the Flow Characteristics of the Spray Nozzle (관창의 유동특성에 관한 연구)

  • 이동명
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.55-60
    • /
    • 2003
  • This study established analysis theory for flow characteristics prediction of the spray nozzle and predicted discharge and discharge type of the spray nozzle from numerical analysis. It could know that discharge type of the spray nozzle from prediction data determine to position of nozzle and needle, and flow characteristics prediction of the spray nozzle could know that the characteristics according to shape of nozzle and needle is decided. New model of the spray nozzle that can maximize efficiency of fire suppression from flow characteristics and prediction data of the spray nozzle is presented. The result of this study utilize to data necessary to develop new model of the spray nozzle. Also the result of this study wish to contribute to resource technology security of the spray nozzle, technique ripple effect enlargement of same kind industry and technical development activation of fire protection field etc.