• 제목/요약/키워드: Fire barrier

검색결과 60건 처리시간 0.025초

일본 가가와현 산불피해지의 복구대책 (The Restoration of Forest Fire Area in Kagawa Prefecture, Japan)

  • 전근우;이시영;임영협;탄원등지자;강기차부
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.238-241
    • /
    • 2007
  • The forest seemed apparently to die on the forest fire area in Honjima, Kagawa Prefecture, Japan. However, the soil that became growing basic of vegetation hardly suffered damage, and the forest recovery was started by the sprout, etc. in the next year. For restoration of forest fire area, the fascine mulching works and log barrier works using the damaged trees were used for the upper-stream, and chack dam and erosion control dam were set up in the downstream. Also, the forest restoration was tried with the plants and the microorganism that inhabit in Honjima to preserve a peculiar forest ecosystem.

  • PDF

초고층 건축물용 내화벽체 요구성능 및 개발방향 설정을 위한 기초연구 (A Basic Study on Required Performance and Development Direction of Fire Resistance Wall on High-rise Building)

  • 김대회;박수영
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.1-7
    • /
    • 2011
  • 최근 초고층 건축물의 방재분야에 대한 관심이 증가하고 있으며, 특히 화재발생 시 고층으로 인한 피난시간의 증가에 대비하여 건축물내의 화재전파를 최소로 억제하고자 노력하고 있다. 방화구획은 건축물에서 화재전파를 억제하는 대표적인 방법으로 내화성능이 있는 벽체와 방화문을 이용하여 화재발생 시 해당구획내에서 연소가 종료되거나 타 구획으로의 화재전파시간을 증가시킴으로써 피난시간을 확보하게 된다. 그러나 현행 건축법에는 초고층건축물을 고려치 않은 최대 2시간 내화성능만은 요구하고 있어 초고층 건축물용 방화벽의 개발에 걸림돌이 되고 있다. 따라서 본 연구에서는 내화벽체의 성능등급에 대하여 검토하였으며, 향후 초고층 건축물용 내화벽체 개발을 위하여 내화성능, 시공성, 사용성 등을 고려한 제품개발 방향을 제시하였다.

화학보호복의 화재위험성 및 화학적 투과시험을 통한 파과시간산정에 관한 실험적 연구 (An Experimental Study on the Fire Risk Assessment & Calculation Breakthrough Time through Permeation Test of Chemical Protective Clothing)

  • 고재선;박평규
    • 한국화재소방학회논문지
    • /
    • 제24권2호
    • /
    • pp.21-30
    • /
    • 2010
  • 본 연구는 화학보호복 원단들에 대하여 내화학성 및 난연성을 조사하기 위하여 ASTM 및 ISO의 방법을 이용하여 내화학성 및 화재위험성시험을 실시하였다. 시험결과 폴리에틸렌의 경우 전혀 난연성이 없는 것으로 분석되었지만 고무에 데카브롬 등 난연성 물질이 첨가된 불소고무 원단이 뛰어난 난연성을 보였다. 특히 현재 소방용 방열복으로도 사용되고 있는 알루미늄 필름에 아라미드원단을 라미네이팅한 원단이 가장 뛰어난 난연성을 보였다. 하지만 내화학성에 있어 알루미늄은 4% NaOH에 부식되는 결과를 보이고 있어 이를 극복하기 위한 방안으로는 다층의 베리어성 필름을 사용하는 것이 좋을 것으로 사료된다. 아울러 난연성 시험결과 알루미늄필름과 폴리머 베리어성 필름을 소재로 만든 Dual skin과 불소고무에 난연성 물질이 포함된 것을 소재로 만든 Single skin이 화학보호복으로 적합한 것으로 판단된다. 또한 열방호실험과 열전달지수실험결과 두께의 증가와 다층구조일수록 TPP와 HTI 증가하는 것으로 나타났다. 향후 화학 보호복 원단의 화재위험성 및 내화학성시험 등 지속적 연구와 보완이 적절한 화학보호복 원단 성능개선에 기여할 것으로 기대된다.

성능위주 소화설비 적용을 위한 표준랙크의 화재확산속도 평가 (Evaluation on Fire Spread Speed of Standard Rack in Korea for Performance based Fire Extinguishing System)

  • 조규환;여인환
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.84-91
    • /
    • 2016
  • 물품이 수직 집약적인 형태로 적재되는 랙크식 창고는 화재발생 시 화염의 급속한 상승으로 인해 그 피해가 매우 심각하다. 이에 ESFR 및 In-Rack 스프링클러, 수직 및 수평차단막 등, 다양한 소화설비 적용을 통해 화재확산 억제에 노력하고 있으나 랙크의 크기 및 적재밀도, 적재물품의 종류 등, 매우 다양한 구성조건으로 인해 적절한 소화설비 선정에 어려움이 있다. 이에 본 연구에서는 현장조사 및 설문조사 등을 통해 국내 랙크식 창고 실정을 반영한 표준랙크를 제작하였으며, 발화위치 조건에 따른 화재특성 확인을 위해 실규모화재시험을 수행하였다. 이를 통해 도출된 화재확산속도는 향후, 개발 및 적용 예정 소화설비들의 성능비교를 위한 기초자료로서 유용하게 활용될 것으로 기대한다.

LPG 판매업소의 위험성 제어계획 (Planning for Safety Control on LPG Distribution Depot)

  • 노삼규;전성우;강태희;서영민
    • 한국화재소방학회논문지
    • /
    • 제12권4호
    • /
    • pp.21-30
    • /
    • 1998
  • LPG 판매업소의 용기보관창고는 보관량이나 위해 상황을 충분히 고려하지 않은 상태로 단순히 방폭벽 구조에 의한 안전규제에 의존해 왔다 따라서 LPG폭발로 인한 보관창고 의 안전규정은 안전완충거리를 충분히 확보하고 있는지 확인할 필요가 있다. 기존의 안전 규제는 그러한 보관창고로부터 사고시 인근에 위치한 구조물과 연간 활동에 미치는 잠재 적 초과압력이나 방출열의 정도를 고려하고 있는지 그 확인이 요구된다. 본 연구는 P PHAST와 IAEA의 위험성 평가와 우선 순위 선정수법, 일본의 LPG 판매소 안전규정 등 을 통하여 안전거리를 산출하였다. 이 결과에 의하면 기존의 LPG판매소의 방폭벽은 추가 적인 안전거리가 요구된다.

  • PDF

The Effect of Spacer on Microclimate and Comfort Sensation in Protective Clothing for Firefighters

  • Chung, Gi-Soo;Lee, Dae-Hoon
    • 한국의류산업학회지
    • /
    • 제4권6호
    • /
    • pp.564-566
    • /
    • 2002
  • Protective clothing for firefighters typically consists of a flame resistant outer shell and inner layers. The inner layers are generally composed of a moisture barrier and a thermal barrier. On performing the task in fire place the heat and perspiration generated from the body become trapped inside the protective clothing. Those heat and moisture result into heat-stress and physical fatigue of fire fighter, which hinder the work. Therefore, the system of clothing designs and material layers must be chosen carefully to balance protection and comfort. 3 kinds of protective clothing of 3 layer structure were used in the experiment of physiological comfort. From the comparison of wear trials with the 3 kinds of layers in firefighters clothing, it indicates that the moisture dissipation of A+B2+C was highest, following A+BI+C andA+B3+C. And the heat dissipation of A+BI+C and A+B2+C were better than A+B3+C. In the protective clothing with A+B3+C, heat and perspiration generated through exercise remained in clothing system long and caused discomfort.

굴 패각을 사용한 경량기포 콘크리트의 단위시멘트량에 따른 물리적 성능에 관한 연구 (Study on physical performance of lightweight foam concrete using oyster shells according to unit cement content)

  • 홍상훈;신종현;신동욱;김봉주;정의인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.102-103
    • /
    • 2020
  • Research for heat insulation of buildings is being carried out, in which a heat exchange barrier is used around the openings and balcony parts as a method for heat exchange blocks. However, the preparation for a fire is inadequate. In order to improve the EPS used as a heat exchange barrier in an attempt to solve this, there is a study on lightweight foamed concrete, but as the amount of EPS used for strengthening fire resistance increases, it becomes lower. There is no strength applied to buildings, and also. There is a limit to the amount of EPS used. In the study, we use oyster shells to secure the EPS replacement rate limit of lightweight Foamed concrete, and try to measure the change of physical properties depending on the unit cement content.

  • PDF

웹 기반의 3차원 형상정보를 활용한 내화방벽 관통부 관리시스템 개발 (Web-based Management System for Fire Barrier Penetration by using 3-dimensional Plant Model)

  • 오승준;임현태;김정욱
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.125-128
    • /
    • 2012
  • 국내 가동원전에서는 내화방벽 관통부의 성능이 적절하게 유지되도록 주기점검절차, 데이터베이스 등 발전소 상황에 적합한 관리방안을 수립하여 운영하고 있다. 이 중에서 내화방벽 관통부 유지관리용으로 구축된 데이터베이스는 관통부 유지관리에 필요한 필수정보가 수록되어 있으나 관통부 담당자의 개인 관리도구로 활용되고 있으므로 실효성 향상이 필요하다. 본 논문에서는 이러한 점을 보완하기 위하여 발전소 구조물, 관통부 등의 3차원 형상정보(3-dimensional Plant Model)를 활용하여 시각적인 관리 편의를 향상시키고, 웹 기반(Web-based)의 관통부 정보 구축을 통하여 발전소 수준(Plant-level)에서 관리가 가능한 관통부 관리시스템 개발 사례를 기술하였다.

  • PDF

한국 소방복의 착용만족도 및 착용자 의견에 관한 조사연구 (A Survey on the Actual Wearing Conditions of Fire Fighter's Uniform)

  • 정정숙;이연순
    • 대한가정학회지
    • /
    • 제37권11호
    • /
    • pp.75-83
    • /
    • 1999
  • To develope an efficient fire fighter’s uniform for the fire fighting work and body protection, this study examined the regulations of fire lighter’s uniform and surveyed the actual wearing conditions, satisfaction degree, preferred color and design others. The results are as follows; 1. As for the satisfaction degree, the degree was normal in ordinary, low in working uniform and heat-proof uniform and very low in water-proof uniform about its design, size, color and materials. 2. As for the color, red was preferred for the working uniform and water-proof uniform. Blue, yellow and green was preferred next for corking uniform and yellow and blue for water-proof uniform. 3. As for the design, fire fighters wanted partial revision of the present uniform. They preferred stretchy training wear style and overact style in order. For the water-proof uniform, they preferred hip-length suit and pants and next to it they liked flee-length suit, waist belt and overact in order. 4. As for the regulations of the uniform, they wanted some addition in casual uniform, water-proof pants and water-proof gloves, and some deletion in the thermal barrier of water-proof uniform and ordinary uniform. 5. As for the distribution of the uniforms, the use of coupons was highly preferred.

  • PDF

슬라이딩아크 방전과 코로나 방전의 복합공정을 통한 유해물질 처리효율 개선에 관한 연구 (A Study on Combined Processes of Sliding Arc Plasma and Corona Dielectric Barrier Discharge for Improve the Efficiency Treatment of Harmful Substance)

  • 권우택;이우식
    • 한국화재소방학회논문지
    • /
    • 제28권6호
    • /
    • pp.108-113
    • /
    • 2014
  • 유해물질처리를 효율적으로 개선하기 위해 슬라이딩아크방전(sliding arc plasma)과 corona dielectric barrier discharge(CDBD공정)의 복합공정을 이용하였다. 이장치는 OH 라디칼과 음이온을 생성하여 강력한 산화력으로 탈취 및 살균 효과를 가진다. 실험결과 SAP 반응기의 크기를 80 A를 50 A로 축소하여도 유해물질의 농도는 큰 변화가 없는 것으로 나타나 반응기의 규모를 최소화할 수 있을 것으로 판단된다. 그리고 CDBD 반응기에서 생성된 음이온과 오존은 유해물질과 반응한 후 음이온은 510,000 ppb에서 470 ppb, 오존은 98 ppb에서 22 ppb로 낮아짐을 확인하였다. 또한 플라즈마 발생장치의 안정성 및 내구성이 우수한 것으로 판단되었다. 따라서 본 연구를 통하여 향후 플라즈마복합공정을 이용하여 실내공기중에 존재하는 유해물질 제거를 효율적으로 할 수 있을 것으로 생각된다.