• Title/Summary/Keyword: Fire alarm

Search Result 257, Processing Time 0.028 seconds

Design and Implementation of Optimal Control Algorithms for Building Energy Management (빌딩 에너지 관리 최적화 알고리즘 설계 및 구현)

  • Jin Jung-Hwa;Chung Sun-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.969-976
    • /
    • 2004
  • Building energy saving is one of the most important issues in these days. Energy saving control strategies should be developed properly to achieve the saving. One of such area we could apply is the HVAC (Heating, Ventilation and Air-Conditioning) system. Through the optimal control algorithm for building energy management system (EMS), you can not only save the cost of building energy, but also protect HVAC system components against the unexpected condition. In order to verify the effectiveness of building energy saving, field test was accomplished for several months at 'A' building. And to get the measured data, remote control was used. If the remote control is used in BAS (Building Automation System), control and monitoring can be done for all of the building systems, such as HVAC, power, lighting, security and fire-alarm etc. anywhere any time. Using the remote control, Control and monitoring is possible for the testing system without going there. As the results of field test, we could reduce $5{\sim}10\%$ of the building energy cost.

Development of WSN(Wireless Sensor Network)-based Fire Monitoring Application System using Fire Detection Algorithm for Early Warning (조기 경보를 위한 화재 판단 알고리즘을 이용한 무선 센서네트워크 기반 화재 감시 응용 시스템 설계 및 구현)

  • Kim, Ah-Reum;Jo, Kyoung-Jin;Chang, Jae-Woo;Sim, Chun-Bo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.504-514
    • /
    • 2009
  • Recently, fire monitoring application systems have been an active research area due to the safety of industries, historical monuments and so on. The fire monitoring application systems can reduce the damage of properties by providing earlier warning for possible fire situation. However, the existing systems have a drawback that they detect fire with delay due to their uniform epoch in fire detection algorithm. Moreover, they do not provide user-friendly graphical user interfaces in their fire monitoring systems. To resolve the problems, First, we propose a new fire detection algorithm (Early Fire Detection Fire Algorithm) which uses the distribution of sensing data for early fire detection. Our fire detection algorithm is better in terms of fire detection time than the existing work because it can set a start time of fire detection epoch dynamically based on data distribution. Second, we develop a fire monitoring application system which provides users with both a user-friendly graphical user interface and a fire alarm message when fire occurs. Finally, we show from our experiment that our developed system is effectively used for early fire warning in a variety of fire situations.

Efficient Forest Fire Detection using Rule-Based Multi-color Space and Correlation Coefficient for Application in Unmanned Aerial Vehicles

  • Anh, Nguyen Duc;Van Thanh, Pham;Lap, Doan Tu;Khai, Nguyen Tuan;Van An, Tran;Tan, Tran Duc;An, Nguyen Huu;Dinh, Dang Nhu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.2
    • /
    • pp.381-404
    • /
    • 2022
  • Forest fires inflict great losses of human lives and serious damages to ecological systems. Hence, numerous fire detection methods have been proposed, one of which is fire detection based on sensors. However, these methods reveal several limitations when applied in large spaces like forests such as high cost, high level of false alarm, limited battery capacity, and other problems. In this research, we propose a novel forest fire detection method based on image processing and correlation coefficient. Firstly, two fire detection conditions are applied in RGB color space to distinguish between fire pixels and the background. Secondly, the image is converted from RGB to YCbCr color space with two fire detection conditions being applied in this color space. Finally, the correlation coefficient is used to distinguish between fires and objects with fire-like colors. Our proposed algorithm is tested and evaluated on eleven fire and non-fire videos collected from the internet and achieves up to 95.87% and 97.89% of F-score and accuracy respectively in performance evaluation.

Electrical Fire Detection System using Temperature and Current Detectors (열.전류 감지기를 이용한 전기화재감지시스템)

  • Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.7-12
    • /
    • 2007
  • This paper presents the development of an electrical fire detection system using digital temperature and current detectors in order to sound for electrical fire in advance. As the demand for electricity is increasing and industrial facilities are getting more complex and larger in size, the losses of human life and property are on the increase by electrical fires. In order to prevent electrical fires, it is required to find out fire signatures, or electric signal of the overcurrent and overheating. Therefore, in this paper, developed is an electrical fire detection system based on the detection of signal for overcurrent and overheating to prevent electrical accidents in advance that happen in electrical wires. The developed system gives an alarm by computer monitor, speaker system and mobile phone before electrical fires occur and give severe damages to human beings and properties, and the system can be implemented and supplied for business and residental buildings at a low price. The usefulness and validity of the system, also, verified in this paper by case study and experiments.

Analysis of Waterproof Time by Number of Twists between Ordinary Fire Hose and Anti-twist Fire Hose (일반 소방호스와 꼬임방지 소방호스의 꼬임 횟수에 따른 방수시간 분석)

  • Hong, Suk-Hwan;Kim, Seo-Young;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.55-60
    • /
    • 2021
  • This study is to check waterproof by number of twists of fire hose and measure the first waterproof time to analyze the relationship between twists of fire hose and first waterproof time and waterproof by position of twists so as to suggest the efficient plan to prevent twists of fire hose. Ordinary fire hose did not make waterproof in case that position of twists was near the nozzle with twists 5 times or more, while anti-twist fire hose had no problem for waterproof only with delayed time. Like ordinary fire hose, anti-twist fire hose also showed the tendency to increase the waterproof time in proportion to the number of twists. In case that the position of twists was near waterproof port even with 10 times of twists in anti-twist fire hose, the first waterproof time was increase by 0.63 seconds on average without any problem for waterproof, which was somewhat faster than that in ordinary fire hose. With respect to the position of twists, waterproof of anti-twist fire hose was affected more as the number of twists was increased more near the nozzle rather than near the waterproof port, like ordinary fire hose. In summary, anti-twist fire hose equipped with anti-twist tool at the middle connection port and the nozzle showed a good waterproof performance with delayed waterproof time regardless of number of twists, as a solution for the twist problem of ordinary fire hose.

A Study for the Fire Hazard Evaluation through the Fire Simulation of an Apartment Fire Accident (아파트 화재 사례 전산모사를 통한 화재위험성 평가에 관한 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.69-78
    • /
    • 2010
  • In this study, Fire Hazards were evaluated through computer simulation using FDS program for an apartment fire accident. The results of fire simulation showed that the maximum heat release rate in the case of no sprinklers activation was 7,700 kW which was about 16 times of that in the case of sprinklers activation, 497 kW and there was a very high fire hazard due to the backdraft phenomenon when the door of fire room was forced to open. Regarding the hazard time of fire room temperature and detection time of detectors, available evacuation time was 32.5 seconds of minimum to 53.5 seconds of maximum. In the case of sprinklers activation, fire hazard in the apartment was showed to be very low due to the fire control by the spray cooling of sprinklers. This study shows that what a important function for fire safety is the activations of fire sprinkler system and emergency alarm system and what a large loss can cause if these systems don’t activate in fire accidents.

A Study on Integrated Fire Alarm System for Safe Urban Transit (안전한 도시철도를 위한 통합 화재 경보 시스템 구축의 연구)

  • Chang, Il-Sik;Ahn, Tae-Ki;Jeon, Ji-Hye;Cho, Byung-Mok;Park, Goo-Man
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.768-773
    • /
    • 2011
  • Today's urban transit system is regarded as the important public transportation service which saves passengers' time and provides the safety. Many researches focus on the rapid and protective responses that minimize the losses when dangerous situation occurs. In this paper we proposed the early fire detection and corresponding rapid response method in urban transit system by combining automatic fire detection for video input and the sensor system. The fire detection method consists of two parts, spark detection and smoke detection. At the spark detection, the RGB color of input video is converted into HSV color and the frame difference is obtained in temporal direction. The region with high R values is considered as fire region candidate and stepwise fire detection rule is applied to calculate its size. At the smoke detection stage, we used the smoke sensor network to secure the credibility of spark detection. The proposed system can be implemented at low prices. In the future work, we would improve the detection algorithm and the accuracy of sensor location in the network.

  • PDF

A Study on Fireproofing Application by Fire Magnitude (화재규모에 따른 화학공장의 내화구조 적용에 대한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.46-52
    • /
    • 2018
  • Interest in fire prevention/fighting has been increased by large fire. It is important to install/manage the detector, alarm, firefighting facility, evacuation route and so on to minimize the damage from fire. Chemical plant is generally constructed by steel structure. So fireproofing is significantly required to chemical plant because steel structure should endure during fire. Currently, fireproofing should be applied up to 6m from ground by local regulation. But chemical plant can handle the large amount of flammable materials or only non-flammable materials. Required of fireproofing height by fire magnitude is studied in this thesis.

Effects of Auditory Warning Types on Response Time and Accuracy in Ship Bridges (선교내에서 청각경보음의 유형이 반응속도와 정확성에 미치는 영향)

  • Ha, Wook-Hyun;Park, Sung-Ha;Kim, Hong-Tae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.673-680
    • /
    • 2010
  • The effects of different auditory warnings on response time and accuracy were studied in a laboratory ship-bridge work environment. Subjective preference on the type of auditory warnings was also of a primary concern. Twenty five subjects were asked to select an appropriate button for the warning sound presented with three types of auditory warning (abstract sound, auditory icon, and voice alarm) and five levels of warning situation (fire, steering failure, collision, engine failure, and low power). Results showed that the response time and accuracy was significantly affected by the types of auditory warning. The voice alarm resulted in a higher accuracy and subjective preference, as compared to the auditory icon and abstract sound. Regarding the response time, auditory icons and voice alarms were equivalent and superior to abstract sounds. Actual or potential applications of this research include guidelines for the design of integrated ship bridge systems.

Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire (고양종합터미널화재 시 소방시설의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.95-107
    • /
    • 2018
  • This study analyzed the working conditions of the fire protection system in the Goyang Bus Terminal fire based on the fire investigation results. The results were as follows. First, extinguishing using an indoor fire hydrant was not attempted immediately after the fire burned the ceiling urethane foam. Second, a sprinkler alarm valve was turn off and did not work in the repair work space of the 1st basement. On the other hand, the sprinklers in the $2^{nd}$ basement, $1^{st}$ floor, $2^{nd}$ floor, and $3^{rd}$ floor worked and prevented the fire from moving to stories other than the $1^{st}$ basement. Third, although an exit light worked normally, it was not installed in the exit from the waiting room in the $2^{nd}$ floor to the bus stop. This resulted in many casualties. Fourth, although a fire receiver sent an electrical signal to the fan controller of the smoke control system, it was treated manually in the fan controller and the fan in the $2^{nd}$ floor did not work.