• Title/Summary/Keyword: Fire Window

Search Result 70, Processing Time 0.031 seconds

An Experimental Study on the Verification of Fire Extinguishing Performance According to the Combustion Characteristics of Building Window Frame (건축물 창호 프레임의 연소특성에 따른 방화성능 검증에 관한 실험적 연구)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.54-55
    • /
    • 2021
  • This study compared the fire safety standards for windows of Korea, the U.S. and Japan to prevent fire expansion through exterior wall openings, and conducted experiments using PVC and aluminum window frames, which are widely used in Korea.The experiment is KS F 2845 which combines frames of the same thickness and area with single-window form and 1 hour fire resistance glass with 8T thickness. Experiments showed that the PVC window was about 9 minutes and the aluminum window was about 26 minutes. However, in Korea, there are no test standards for windows installed at the opening of the exterior wall. In addition, fire safety standards for windows shall be established along with the designation of fire prevention zones.

  • PDF

An Experimental Study to Evaluate the Fire Risk of Building Windows (건축물 창호의 화재위험성 평가를 위한 실험적 연구)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.77-78
    • /
    • 2022
  • This study compared the fire safety standards for windows of Korea, the U.S. and Japan to prevent fire expansion through exterior wall openings, and conducted experiments using PVC and aluminum window frames, which are widely used in Korea.The experiment is KS F 2845 which combines frames of the same thickness and area with single-window form and 1 hour fire resistance glass with 8T thickness. Experiments showed that the PVC window was about 9 minutes and the aluminum window was about 26 minutes. However, in Korea, there are no test standards for windows installed at the opening of the exterior wall. In addition, fire safety standards for windows shall be established along with the designation of fire prevention zones.

  • PDF

An Experimental Study on Development of a Window Sprinkler for Fire Spread Prevention along Building External Walls (건물 외벽 화재확산 방지용 윈도우 헤드의 개발을 위한 실험적 연구)

  • Kwark, Jihyun;Kim, Dong-Jun
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.8-13
    • /
    • 2013
  • In case of fire in a high-rise building fire can be easily spread along the building external walls dramatically if the flame comes out through broken windows. There are a few effective methods to prevent the fire spread at the moment. One is using a fire resistance window, and the other is using a window sprinkler that discharges water to resist flame in case of fire. In this study a window sprinkler which is installed on top of windows and prevents fire by discharging water when its heat-responsive element opens was tested using a large scale furnace in accordance with the standard temperature-time graph. Test result showed that one window sprinkler was able to protect a 2,400 mm wide window from fire for 2 hours and the window backside's temperature locally increased up to $126^{\circ}C$ but kept stable around $100^{\circ}C$ for the test duration.

A Study on the Characteristics of Fire Resistance of Window Material in Compartment Fire (건물화재시 창문재료에 따른 내화특성 연구)

  • Hur, Man-Sung;Jang, Moon-Seok;Cho, Soo
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.62-67
    • /
    • 2003
  • The full-scale compartment fire tests were carried out to evaluate the characteristics of fire resistance of window material under actual fire conditions. The room size used for full-scale room fire tests was 4 by 3.8 m with 2.4 m high ceiling. The windows with PVC, Aluminum and AL+Wood frame materials were established, sofa and mattress were used as fire sources. The window contained pair glasses with the air between 6 mm glasses. Temperatures at total 32 points in the room were measured to find the temperature distribution in the room fire. It is examined that thermal effects on window frame materials such as charring, distortion, melting, structural collapse, and other effects.

The Experimental Study for Radiant Heat Flux of Non-insulated Glazed Window in Fire (화재시 비차열 유리의 복사열에 관한 실험적 연구)

  • Park, Soo-Young;Seo, Hee-Won;Kim, Dae-Hoi;Wang, Nam-Woong;Yeo, In-Hwan;Choi, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.26-33
    • /
    • 2014
  • Recently in Korea, the interest for using window and window-wall in building picks up due to the beauty and utilization of space. But, interior space of the buildings shall be compartmentalized by fire resistance structures in accordance with the Korean building codes to prevent the spread of flame and damage of human life in fire. In case of installing non-insulated glazed window in compartment wall, the flame spread to adjacent space and the damage of human life by radiant heat can occur in fire. On this study, to confirm the risk of radiant heat for non-insulated glazed window in fire, the fire resistance tests were conducted. The temperature rise and heat flux on unexposed space was measured and analyzed.

A Numerical Study of Fire Dynamics of The Enclosed Compartment with Window Glass Breaking (밀폐된 구획의 창유리 파단시 화재 특성에 관한 수치적 연구)

  • 전흥균;최영상
    • Fire Science and Engineering
    • /
    • v.12 no.2
    • /
    • pp.29-42
    • /
    • 1998
  • The use of computer supported fire safety engineering calculations has grown significantly in recent years and will be increased rapidly. In this study, in order to examine for fire dynamics of the enclosed compartment with window glass(3mm, 4mm thickness) when the window glass breaks, we conducted numerical computer simulations about foam sofa fire with the zone type computer mode, FASTLite package(version 1.1.2) and the Berkeley algorithm for breaking window glass in a compartment fire, BREAK1 program (version 1.0). The analysis of the results in this paper shows that there are differences of fire dynamics between open-or enclosed-state compartment fire and the enclosed compartment fire with window glass breaking. It is also shown in this study that backdraft phenomenum occurs due to accumulated unburned combustible fuel when the glass of 4mm thickness breaks, and that temperature differences between the inner-and outer-surfaces of 3mm and 4mm thick glasses are appreciable. This study will help fire fighter to establish fire suppression or occupant's refuge strategies and fire safety engineer to enhance simulation techniques about the five dynamics of compartment fire.

  • PDF

A Experimental Study on Window Glass Breakage in Compartment Fires (구획 화재시 창유리 파괴 현상에 관한 실험적 연구)

  • 이수경;김종훈;최종운;이정훈
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.21-30
    • /
    • 1998
  • This is a study on the relation of window glass breaking time, shape, and vent condition in a compartment fire through the experiment. We recognize the phenomenon that window glass breakage in a compartment fire be arose from the thermal stresses due to the temperature temperature difference was 233.4$^{\circ}C$ for test 1-3, 138$^{\circ}C$ for text 2-1, 83.6$^{\circ}C$ for test 2-2. The interior test 2-2, 400.9$^{\circ}C$ for test 2-3. so if the flame didn't reach at the surface of window glass, the breakage of glass occure at 40$0^{\circ}C$~50$0^{\circ}C$. when the fire size reached to 1541.14kW, the window might be broken by thermal stress. But window glass was not collapsed.

  • PDF

A Study on the Fire Safety Design Methods of Opening in High-rise Building (초고층고층 건축물의 개구부에 대한 화재안전 설계방법 조사)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Lee, Byeong-Heun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.8-9
    • /
    • 2018
  • In recent years, the fire risk in the aged housing facilities in high-rise building has been closing up due to the fire in the Grenfell Tower. In the case of these high-rise residential facilities, fire cases of residential facilities such as Uijeongbu Apartment Fire The fire hazard has been reexamined mainly. Especially, the fire of these residential facilities is very closely related to the window, so measures are needed. On the other hand, in Korea, there is almost no fire safety measures against these openings. Therefore, this study suggests improvement measures by comparison with advanced countries based on fire safety measures for domestic windows.

  • PDF

School-Building Remodelling Model using Discriminant Analysis - A Case Study for Class Rooms in School Building - (학교건물의 노후화에 따르는 개축 판정에 관한 모델의 정립)

  • Min, Chang-Kee
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.4 no.4
    • /
    • pp.29-41
    • /
    • 1997
  • The objective of this paper is to construct a model to be used in deciding whether to repair or rebuild school buildings is depending on their ages and other factors. The theme of this paper is the age is the main variable but other factors such as floor, innerwall, ceiling, door, inner window of the class room, outer window of the class room, inner window of the corridor, outer window of the corridor, middle window between the classroom and the corridor, light, heater, speaker, fire protection sensor, TV monitor, and telephone status would influence the final decisions. This paper employs an experimental case study method. Using the stepwise, statistical, classification method commonly used in discriminant analysis, it evaluates 12,766 rooms of 87 different high schools in Seoul. The result of this study indicates that some critical variables influencing the final decisions are the status of TV monitor, middle window between the classroom and the corridor, light, inner window of the corridor, fire protection sensor, innerwall, speaker utensil, outer window of the class room, and door of the class room. This paper also suggests a linear discriminant function will be used for this kind of studies. Finally the paper recommends policies with respect to the variables and discriminant functions evaluated.

  • PDF

A Study on the Characterization of Fire Plume Ejected from an Opening according to the Opening Form and the Balcony of Apartment in Korea (국내 공동주택의 개구부형태 및 발코니 유·무에 따른 분출화염 성상에 관한 연구)

  • Lee, Kyu-Min;Koo, Tae-Yoon;Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.37-38
    • /
    • 2017
  • This study identified the effects of flame on the upper by fire plume ejected. we implemented model experiment according to investigation of housing area effect, window aspect ratio and balcony availability. we confirmed that opening ratio was increased according to housing area larger. the square window confirmed that is progressing fire plume ejected of free space. According to the value of an opening aspect ratio 'n' getting higher, the horizontal widow is getting that increased the risk as the fire spread an external to the top of opening. it is determined to the fundamental solution about fire safety in the extended balcony of apartment.

  • PDF