• Title/Summary/Keyword: Fire Surveillance

Search Result 82, Processing Time 0.025 seconds

Design and Implementation of U-city Infrared Image Surveillance System (U-city 적외선 영상 감시 시스템의 설계 및 구현)

  • Kim, Won-Ho;Jang, Bok-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.561-564
    • /
    • 2009
  • This paper present design and implementation of U-city infrared image surveillance system based on the digital media processor. The hardware is designed and implemented by using commercial chips such as DM642 processor and video encoder, video decoder and the functions of software are to analyze temperature distribution of a monitoring image and to monitor disaster situation such as fire. The required functions and performances are confirmed by testing of the prototype and we verified practicality of the system.

  • PDF

A Study on the design of Unmanned Autonomous Helicopter for Aerial Monitoring and Control of a Large Size Disaster and Forest Fire (대형재난 및 산불 공중지휘통제용 무인자율헬기 개발에 관한연구)

  • Kim, Jong-Kwon;Kwark, Ji-Hyun;Son, Bong-Sei
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.105-110
    • /
    • 2008
  • Unmanned helicopter has several abilities such as vertical take off, hovering, low speed flight at a specific altitude. Such vehicles are becoming popular in actual applications such as search and rescue, aerial reconnaissance and surveillance in the case of a large size disaster and forest fire. In this paper, a flight control system was designed for an unmanned helicopter. This paper was concentrated on describing the systematic design, electronic equipments and their interconnections for realizing the autonomous flight and aerial monitoring. A study on the autonomous waypoint navigation and altitude control performance were performed and tested on a test unmanned helicopter and the performance and the feasibility were represented.

  • PDF

Development of Real-time fire and Smoke Algorithms Using Surveillance Camera in Tunnel Environment (터널 내 감시 카메라 영상을 이용한 실시간 화염 및 연기 탐지 기법의 개발)

  • Lee, Byoung-Moo;Han, Dong-Il
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.219-220
    • /
    • 2007
  • In this paper, we proposed image processing technique for automatic real time fire and smoke detection in tunnel environment. To avoid the large scale of damage of fire occurred in the tunnel, it is necessary to have a system to minimize and to discover the incident as fast as possible. The fire and smoke detection is different from the forest fire detection as there are elements such as car and tunnel lights and others that are different from the forest environment so that an indigenous algorithm has to be developed. The two algorithms proposed in this paper, are able to detect the exact position, at the earlier stage of incident.

  • PDF

Introduction of Intelligent fire-disaster Surveillance System for Subway Station (도시철도 역사 지능형 화재감시시스템 구축방안 연구)

  • Shin, Jeong-Ryol;An, Tae-Ki;Jeon, Bo-Ik;Kim, Gab-Young;Kim, Hyung-Min;Yun, Byeong-Ju
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.457-465
    • /
    • 2009
  • Subway system including light-rail transit system is the representative public urban transportation. Accordingly, Nothing is more important than the safety operation as well as passengers' convenience. Due to the fire disaster of Daegu subway on 2003, more strict regulations of detecting fire and of conducting on emergency circumstances. However, regardless of this improved management, it was reported that installations of lots of fire-detection facilities may be harm than good to operate subway system due to frequent malfunction of some fire-detection facilities. It may cause mis-alarm for fire and induces abnormal operation of subway due to the strict regulation; the train shall be stopped on emergency circumstances. Therefore, in this paper, new scheme on surveiling breaking-out-of fire in the station is suggested with new IT technologies, Wireless Sensor Network(WSN) and CCTVs. which were integrated with an intelligent software. This intelligent system enables to surveil breaking-out-of fire in real time through sensor network technology and watch the emergency site on CCTV as well. Through this system, subway organizers could cope with the emergency circumstance rapidly as well as judge precisely whether fire breaks out or not.

  • PDF

Real-time Smoke Detection Research with False Positive Reduction using Spatial and Temporal Features based on Faster R-CNN

  • Lee, Sang-Hoon;Lee, Yeung-Hak
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1148-1155
    • /
    • 2020
  • Fire must be extinguished as quickly as possible because they cause a lot of economic loss and take away precious human lives. Especially, the detection of smoke, which tends to be found first in fire, is of great importance. Smoke detection based on image has many difficulties in algorithm research due to the irregular shape of smoke. In this study, we introduce a new real-time smoke detection algorithm that reduces the detection of false positives generated by irregular smoke shape based on faster r-cnn of factory-installed surveillance cameras. First, we compute the global frame similarity and mean squared error (MSE) to detect the movement of smoke from the input surveillance camera. Second, we use deep learning algorithm (Faster r-cnn) to extract deferred candidate regions. Third, the extracted candidate areas for acting are finally determined using space and temporal features as smoke area. In this study, we proposed a new algorithm using the space and temporal features of global and local frames, which are well-proposed object information, to reduce false positives based on deep learning techniques. The experimental results confirmed that the proposed algorithm has excellent performance by reducing false positives of about 99.0% while maintaining smoke detection performance.

A study on Installation of Facility Monitoring System in Computer Room's (전산실 기반설비감시시스템 구축에 관한 연구)

  • Choi, Woo-hyoung;Kim, Chang-soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.159-161
    • /
    • 2013
  • Surveillance system that can respond quickly in case of failure to detect various disorders that can occur for a temperature chamber, and fire extinguishing equipment, such as UPS, communication room, and computer room of enterprises and institutions operating in infrastructure, and to systematically study. Major telecommunications equipment and computational facilities to manage, operating in an environment of air conditioners work status, distribution panel and the UPS status and fault status, rapid notification system in case of fire is needed. By identifying the status and problems of disability surveillance on the periphery of the existing computer room's infrastructure management guidelines presented in the next future Conception and systematic surveillance system for staff to refer to when designing considerations associated with data center monitoring system the necessity of the various studies are presented.

  • PDF

Smoke color analysis of the standard color models for fire video surveillance (화재 영상감시를 위한 표준 색상모델의 연기색상 분석)

  • Lee, Yong-Hun;Kim, Won-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4472-4477
    • /
    • 2013
  • This paper describes the color features of smoke in each standard color model in order to present the most suitable color model for somke detection in video surveillance system. Histogram intersection technique is used to analyze the difference characteristics between color of smoke and color of non smoke. The considered standard color models are RGB, YCbCr, CIE-Lab, HSV, and if the calculated histogram intersection value is large for the considered color model, then the smoke spilt characteristics are not good in that color model. If the calculated histogram intersection value is small, then the smoke spilt characteristics are good in that color model. The analyzed result shows that the RGB and HSV color models are the most suitable for color model based smoke detection by performing respectively 0.14 and 0.156 for histogram intersection value.

A Study on the Development, Performance and Reliability Certification for Fire Detection System in Outdoor Area (옥외형 화재경보시스템의 개발과 성능시험에 관한 연구)

  • Baek, Dong-Hyun;Ghil, Min-Sik
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.15-18
    • /
    • 2013
  • This paper is concerned with the Performance and Reliability Certification for fire detection system in outdoor area such small and middle sized cultural assets, natural monument and outdoor facilities. Especially, if a fire were to occur in vulnerable area, it is difficulty to detect a fire. therefore we propose a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug. for Adoption of Intelligent Fire Detection System with movable and unmanned function breaking from the existing Conventional Fire Detection System, this Range of R&D includes the Performance test, Function test, Field test, Flame Detection test and EMI/EMS Compliance test. the Result data of Performance test, Function test and Field test is generally good during 3 months. also we checked that thermal variation test and EMI/EMS compliance test are good result data within allowable range. As a result of general test, we verified improvement results that the measure distance of fire detection extend 75 m, the Power of waiting time increase 4 hours, the Power of operation time increase 3 days and the context awareness with video as well as sensors.

Performance Evaluation of Wireless Sensor Networks in the Subway Station of Workroom (지하철 역사내 무선 센서네트워크 환경구축을 위한 무선 스펙트럼 분석 및 전송시험에 관한 연구)

  • An, Tea-Ki;Kim, Gab-Young;Yang, Se-Hyun;Choi, Gab-Bong;Sim, Bo-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3220-3226
    • /
    • 2011
  • In order to monitor internal risk factors such as fire, terror, etc. on the subway station, the surveillance systems using CCTV and various kinds of sensors have been implemented and recently, introduction of surveillance systems using an advanced IT technology, sensor network technology is tried on several areas. Since 2007, Korean government has made an effort to develop the intelligent surveillance and monitoring system, which can monitor fire, intrusion, passenger congestion, health-state of structure, etc., by using wireless sensor network technology and intelligent video analytic technique. For that purpose, this study carried out field wireless communication environment test on Chungmuro Station of Seoul Metro on the basis of ZigBee that is considered as a representative wireless sensor network before field application of the intelligent integrated surveillance system being developed, arranged and analyzed and ZigBee based wireless communication environment test results on the platform and waiting room of Chungmuro Station on this paper. Results of wireless spectrum analysis on the platform and waiting room showed that there is no radio frequency overlapped with that of ZigBee based sensor network and no frequency interference with adjacent frequencies separated 10MHz or more. As results of wireless data transmission test using ZigBee showed that data transmission is influenced by multi-path fading effect from the number and flow rate of passengers on the platform or the waiting room rather than effects from entrance and exit of the train to/from the platform, it should be considered when implementing the intelligent integrated surveillance system on the station.