• Title/Summary/Keyword: Fire Spread Speed

Search Result 40, Processing Time 0.021 seconds

Numerical Experiment on the Variation of Atmospheric Circulation due to Wild Fire (산불 발화에 따른 하층 대기 순환장 변화에 관한 수치 실험)

  • Lee, Hwa-Woon;Tak, Sung-Hoon;Lee, Soon-Hwan
    • Journal of Environmental Science International
    • /
    • v.22 no.2
    • /
    • pp.173-185
    • /
    • 2013
  • In order to clarify the impact of wildfire and its thermal forcing on atmospheric wind and temperature patterns, several numerical experiments were carried out using three dimensional atmospheric dynamic model WRF with wildfire parametrization module SFIRE. Since wind can accelerate fire spread speed, the moving speed of fireline is faster than its initial values, and the fireline tends to move the northeast, because of the wind direction and absolute vorticity conservation law associated with driving force induced by terrain. In comparison with non-fire case, the hydraulic jump that often occurs over downwind side of mountain became weak due to huge heat flux originated by surface wildfire and wind pattern over downwind side of mountain tends to vary asymmetrically with time passing. Therefore temporal variation of wind pattern should be catched to prevent the risk of widfire.

A Study on the Heat Release Characteristic of Household Items using LSC(Large Scale Cone Calorimeter) (LSC를 이용한 생활용품의 발열량 특성에 관한 연구)

  • Park, Ju Young;Baek, Chang Sun;Lee, Hae Pyeong;Hong, Yi Pyo
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.38-44
    • /
    • 2015
  • For this study, fire tests were performed targeting household items (Sofa, Drawer, Refrigerator, Washing machine) using a large cone calorimeter (Large Scale Cone Calorimeter, LSC). The data were obtained focusing on the fire characteristic of the data when the actual fire occurs. The study results showed the following mean HRR of the household items; drawer 2843 KW, sofa 2939 KW, washing machine 719 KW, refrigerator 2907 KW, and THR is found in sofa 2202 MJ, drawer 1559 MJ, refrigerator 1193 MJ, washing machine 627 MJ. From the result, it could be found that the sofa can cause significant heat generation when the fire occurs, and the flashover tendency was found relatively high in compartment fire. In addition, a weight of the four our household items was reduced sharply in a similar time (20min before and after) degree after ignition. The drawer and sofa which has a high heat release can be considered to speed up the fire spread as their weight decrease rapidly and showed relatively weak to the fire compared to the refrigerator and washing machine.

Study of Aerial Fire Line Construction and Suppression Method on Forest Fire (산불 공중진화 방화선 구축형태 및 진화방법에 관한 연구)

  • Bae, Taek-Hoon;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.26-31
    • /
    • 2010
  • In this study, attack process and aerial control line construction type which were considered forest fire type and a case of operations were suggested using the experience of aerial fire attack of all type of forest fires. As the spread rate of forest fire is effected by terrain, slope, wind speed, forest species and etc., we needed to analyze spreading direction, behavior type and intensity before heli-team constructed a aerial control line. Especially, It is important to consider safety of attack team as a their views were obstructed. In this study, we suggested a 13 methods from type A to type M about attack and construction of aerial indirect control line.

An Experimental Study on the Formation of Smoke Layer of Compartment Fire (건물화재시 연기층의 형성에 관한 실험적연구)

  • 허만성
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.94-100
    • /
    • 1997
  • The objective of this research is to study the formations of smoke layer in case of several furniture fires such as trashcan, carpet, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The uniformly distributed fire in case of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as the trashcan, mattress and wardrobe showed that the ignitions and the initial growth periods were relatively long. The descending speed of the interface height was proportioned to the inflammability of the furniture and the spread of the fire. The time required to come down around 1m was within 1-3 minutes. The Interface heights for the furniture fires were around 1m as the steady state. However, at the time of the maximum temperature, the interface height was lowered to 0.25m-0.75m from the floor. The carbon dioxide concentration reached the highest while the oxygen concentration was minimum.

  • PDF

The Study of Burned-Area Analysis Method for Forest-fire Damaged Area - Investigation for ImSil County, GyeongJu City - (산불피해 현장답사를 통한 연소면적 산출 연구 - 임실, 경주 산불을 중심으로 -)

  • Kang, Seo-Young;Lee, Jung-Yun;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.176-181
    • /
    • 2012
  • In this research the 2009 spring occurred during forest fire ImSil and research destination GyeongJu has been selected. Research in the field of the target time exploratory Boundary Data through after air photos, satellite photos and topographic map by using the combustion area was calculated. 2009 March 1-forest fire occurs on the day of the weather information and weather changes wildfire in the check in any affected. Study research destination of combustion is ImSil 161 ha, GyeongJu 270.93 ha. The impact of the weather-temperature dry weather forest fires this favorable situation to occur and the wind directions and the spread of the mountain wind speed was less impact has no arguments.

Measures for Preventing Pressure Fracture of Fire and Flue Tube Boiler (노통연관식 보일러의 압궤사고 방지대책)

  • Lee Keun-Oh
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.14-19
    • /
    • 2004
  • Boiler is a hazardous equipment to have potential explosion ail the time. And not only it has malfunction at explosion. it lead to people death but also secondary accident such as explosion and fire. Therefore, this equipment should not be broken for keeping its own function. And also, high level of safety should be kept in the process of the use not to be malfunctioned. A large scale of accident due to boiler explosion can be preventive in advance. Boiler fracture is occurred by instant expansion (approximately 1700 time) from quick evaporation of rater in boiler, due to pressure decrease in boiler Emitting energy from it is tremendous and it is so dangerous because of its high temperature. Secondary explosion such as fire is also a main hazard occurring at fuel supply place. If any devices with high pressure is broken, then not only boiler vessel but also components of it are spread with high speed, causing secondary accident. This study is to analyze integrally accident cause of fire and flue tube boiler to have occurred pressure fracture actually, to show countermeasures to prevent accident loss from the fire and flue tube boiler.

A Study for Characteristics of Water that Penetrates Wood Flour due to Changes of Concentration of BDG (BDG 농도변화에 따른 용수의 목분 침투특성 연구)

  • Kong, Il-Chean;Park, Il-Gyu;Lim, Kyung-Bum;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.74-79
    • /
    • 2013
  • As the feature of fire, it is hard for deep-seated fire to spread to the deeper site, and it also has danger for being re-ignited cause of recontacting with oxygen after being put off. Now it is ruled in the certification criteria of wetting agent used for extinguishing deep-seated fire that the criteria for surface tension is below 33[mN/m] in Korea. For figuring out how much water for fire-fighiting can permeate into combustibles, in this research, the permeating performance is analyzed by measuring the speed of permeating and transmission quantity released after that, by pouring solution whose surface tension is changed by adjusting concentration of surfactant BDG(Butyl Di Glycol) in column From this result, it is can be determined that transmission quantity becomes less and wet area goes wider as surface tension is lower, and it is also able to be analyzed as quantity of absorbed liquid and wet area is increased because fluid permeates into the core.

Simulation of Ventilation Capability Effect on The Smoke Spread in Railway Station (제연 팬 용량이 철도역사 연기확산에 미치는 영향 분석)

  • Jang, Yong-Jun;Koo, In-Hyuk;Kim, Hag-Beom;Kim, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.7-13
    • /
    • 2011
  • Simulation study were performed for ventilation capability effect on the smoke spread in the deeply-underground subway station(DUSS). Singeumho station(The line # 5, Depth: 46m) was modeled and were analyzed for smoke-spread speed difference between the originally-designed-ventilation-capacity and the measured-ventilation-capacity. Field test data for actual fan in DUSS was applied as a boundary condition of a simulation. The whole station was covered in this analysis and total of 4 million grids were generated for this simulation. The fire-driven flow was analyzed case by case to compare the smoke-spread effects. In order to enhance the efficiency of calculation, parallel processing by MPI was employed and large eddy simulation method in FDS code was adopted.

  • PDF

Study on Horizontal and Vertical Temperature Analysis of Cable Fire in Common Duct using Room Corner Experiment (룸코너 실험을 이용한 공동구 케이블 화재 시 수평·수직 방향 온도 분석에 관한 연구)

  • JaeYeop Kim;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.634-643
    • /
    • 2023
  • Purpose: Underground common duct fires are steadily occurring, and the proportion of property damage is particularly large among property and human casualties caused by fires. Especially, cable fires that occur in common areas can spread vertically quickly and pose a great risk. This paper aims to scientifically analyze the nature of the fire by reproducing the fire through experiments. Method: To analyze the characteristics of cable fires in underground common duct, heat release rate and temperature changes were measured through Room-corner (ISO 9705) test, and the vertical and horizontal propagation of cable fires was quantitatively compared and analyzed. Result: The Room Corner Test (ISO 9705) was used to compare the temperature changes at each data logger point. The results showed that the time it took for the fire to reach the ignition temperature in the horizontal and vertical directions from the center point of the first-tier cable was 589 seconds and 536 seconds, respectively, which means that the vertical fire propagation is 53 seconds faster than the horizontal propagation. This proves that the vertical propagation of fire is relatively faster than the horizontal propagation. The horizontal propagation speed of the fire was also compared for each floor cable tray. The results showed that the third-tier cable propagated at 3.4 times the speed of the second-tier cable, and the second-tier cable propagated at 1.5 times the speed of the first-tier cable. This means that the higher the cable is located, the faster the fire spreads and the larger the fire becomes. Conclusion: This study identified the risks of cable fires and analyzed the risks of vertical fire propagation during cable fires based on the results of the Room Corner Test. Studies to prevent the spread of fire and fire response policies to prevent vertical fire propagation are required. The results of this study are expected to be used to assess the fire risk of common areas and other fires.

A Study on Facilities Damage Characteristics Caused by Forest Fire in Goseong-Gun (고성산불로 인한 시설물피해특성 연구)

  • Yeom, Chanho;Lee, Si-young;Park, Houngsek;Kwon, Chungeun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.469-478
    • /
    • 2019
  • Purpose: In this studies we examine the facilities damage characteristics caused by forest fire. Therefore, we surveyed damaged facilities from forest fire which was occurred on Goseong-Gun on march 28 in 2019.(damaged areas was 40ha) The types of facilities uses were house, public facility, warehouse and so on. 17 facilities were destroyed. The purpose of this study was to for establishing a disaster safety village in rural areas where damage from a similar type of disaster occurs repeatedly by conducting the consciousness survey targeting at experts and disaster safety officials in a local government. Method: We surveyed meteorological factors(temperature, wind speed, wind direction, humidity) per a minute for analyzing weather condition on Goseong-Gun when forest fire was occurred, spread and extinguished. And we surveyed forest fire risk factors(a slope degree, a slope direction, a geographical feature, a distance between forest and facility, main species, the existence of crown fire ignition, the direction of facility, the main material of building) around 10 damaged facilities. Finally, we analyzed damage pattern of facilities using meteorological factor and forest fire reisk fator Result: The weather condition of Kanseonng AWS (No.517) was high temperature, arid and strong wind, when the forest fire was occurred and spread. An average wind speed was 4.1m/s and the maximum wind speed was 11.6m/s. The main direction of wind was W(225~315°). Damaged facilities were located on the steep slope area and on the mountaintop. The forest density around facilities was high and main species was korean red pine. The crown fire was occurred in the forest around damaged facilities. The average distance was 13.5m from forest to facilities. When the main matarial of building was made by fire resistance materials (for example, rainforced concrete), the damage was slightly. on the other hand, when by flammable material (for example, a Sandwich Panel), the facilities were totally destroyed Conclusion: The results of this research which were the thinning around house, making a safety distance, the improvement of main material of building and etc, will be helpful for establishing a counter measure for a forest fire prevention of facilities in wild land urban interface