• Title/Summary/Keyword: Fire Signal

Search Result 196, Processing Time 0.027 seconds

Fire Detection Signal Processing Method Using an Optical Fiber Linear Detector and the Development of an Optical Signal Processing Test Module (광섬유선형감지기를 이용한 화재감지 신호처리방법 및 광신호처리 시험모듈 개발에 관한 연구)

  • Kim, Si-Kuk;Lee, Young-Sin;Kim, Dong-Eun;Lim, Woo-Sub;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.27-34
    • /
    • 2016
  • This paper studies a fire detection system using an optical fiber linear detector which can minimize damage from a fire by the most adaptable even in poor environmental conditions such as a tunnel or utility-pipe conduit vulnerable to fire. Using a strand of optical fiber, temperature can be displayed in intervals of meters and a fire can be detected remotely from a distance of several kilometers. Thanks to its strengths such as high reliability and long life, it is widely applied in harsh environments in the overseas. Therefore demands are expected to grow greatly in Korea as well. However, all optical signal drive and analysis module except for the optical fiber linear detector, tend to rely on import. Firstly this study deduced the location and the method of processing signals measuring temperature by using the optical fiber linear detector in order to develop a technology for a domestic model of fire detection system. Secondly this study designed and manufactured the optical analysis test module, and then we checked its performance.

Subjective Responses for the Fire Signal Sound of Acoustic Reporting Equipment Depending on Visual Information (시각정보 변화에 따른 음향통보장치 신호음의 청감반응)

  • Song, Hyuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.313-319
    • /
    • 2005
  • Instruction and prevention of the safety for a fire have been performed continuously by nation. However, the accident due to a fire is not decreasing and causes a serious calamity to people. It is at the initial stage of fire burning that the most effective way to reduce damage is to evacuate and fight a fire. When a fire burns, the equipments reporting to other person or organization concerned are called 'acoustic reporting equipment'. Among those equipments reporting to person, 'a fire bell' is the easiest equipment to approach. Observing the behaviors of people when a fire burning, some are in a quiet indoor, some in a room with other people, some in a square with many people and some in indoor filled with smoke etc. This study aims to find out an acoustic reporting signal appropriate for visual information. For the experiments, visual-auditory experiments were performed through reporting signals and visual informations with several situations that is able to be faced at when a fire burns.

The Study of Fire Detector Circuit with Wireless Communication (무선통신기능을 갖는 화재감지기 회로에 대한 연구)

  • Baek, Dong-Hyun;Kim, Jang-Won
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.111-115
    • /
    • 2010
  • For the development of fire detector equipments that was fused independent type of fire detector and a wireless communication function, this paper adopted a signal processing method of an independent formation fire sensor by a ZigBee communication method, and it was designed that the combinations of fire detector and wireless communications network were enabled. When a fire occurred, output voltage of a fire detector was 0.4 V, the movement pulse width was $600{\mu}s$, and that was confirmed by an experiment. When it has lookout state, LED worked by 30 s cycle and working current is 0.12 mA. When a fire occurred, LED worked by 0.5 s cycle and working current was 7 mA, and through this experiment of power source, Chamber tester, smoke tester,IRED, LED lighting, the propriety of the method that we showed in this paper confirmed.

Analysis on the Fire Accident of Vehicle Due to Damage of Connector and wiring on an Anti-lock Brake System(ABS) Module (ABS 모듈의 접속부 및 전원배선 손상으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Kim, Jin-Pyo;Nam, Jung-Woo;Park, Jong-Taek;Song, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.13-19
    • /
    • 2017
  • In this paper, study of vehicle fire cases caused by connector and power wiring of anti-lock brake system(ABS) module damage is presented. The purpose of ABS module is to improve braking and steering ability under sudden stop of the vehicle by repeatedly activating and releasing the brake with electric signal via electric control unit. The electric control unit for ABS may experience incomplete contact between power line and signal line or electrical breakdown on the printed circuit board by undergoing repetitive signal change which would consequently result in electrical heat and spark, eventually leading to automotive fire. Therefore, the purpose of this paper is to provide fundamental data by analyzing connector and power wiring of ABS module damage conducive to the precise investigation on the cause of vehicle fire.

A study on modeling and measuring method of tire weight imbalances and improving reliability (ICCAS 2004)

  • Lee, Ki-Seong;Jeong, Tae-Woon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1685-1688
    • /
    • 2004
  • I propose a modeling of a mechanism for weight fire uniformity measurement of a tire and a way I interpret a Sampling signal by Loadcell through an analysis, and to measure fire uniformity in this study. Correct a weight fire uniformity measurement was possible through the production of conversion and influence factor of a signal with a basis with the model who was an oscillation mechanics enemy.

  • PDF

Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations (선풍기의 운전 상황별 발열특성 및 전류신호 검출)

  • Kim, Doo-Hyun;Lee, Heung-Su
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.

Electrical Fire Detection System using Temperature and Current Detectors (열.전류 감지기를 이용한 전기화재감지시스템)

  • Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.7-12
    • /
    • 2007
  • This paper presents the development of an electrical fire detection system using digital temperature and current detectors in order to sound for electrical fire in advance. As the demand for electricity is increasing and industrial facilities are getting more complex and larger in size, the losses of human life and property are on the increase by electrical fires. In order to prevent electrical fires, it is required to find out fire signatures, or electric signal of the overcurrent and overheating. Therefore, in this paper, developed is an electrical fire detection system based on the detection of signal for overcurrent and overheating to prevent electrical accidents in advance that happen in electrical wires. The developed system gives an alarm by computer monitor, speaker system and mobile phone before electrical fires occur and give severe damages to human beings and properties, and the system can be implemented and supplied for business and residental buildings at a low price. The usefulness and validity of the system, also, verified in this paper by case study and experiments.

Design of the Integrated Fire Automation System(IFAS) on based P-Type Fire Control Panel (P형 수신기 기반 통합화재 자동 시스템의 설계)

  • Kim, Hyun-Ju;Park, Jae-Heung;Seo, Yeong-Geon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.12
    • /
    • pp.133-142
    • /
    • 2010
  • P-type fire control panel, currently in use, has a big hazard that can cause the large scaled human death tolls and property damage in the massive fire because it is difficult to identify in real time the location of fire outbreak and whether search-device are broken down or not. In this paper, I suggest that the integrated fire automation system on based p-type fire control panel should be used, which can detect in real time the signal that occur when whether search-device are broken down or not, and can detect the arisen circumstances information of p-type fire control panel on the fire signal in the far away. The devised systems have designed and embodied the analysis of circumstances information and module that can analyze the circumstances information from the p-type fire control panel and the part of internet access installment which can gather and deliver the circumstances information from the fire prevention facility receiver.

Autonomous Mobile Robot Control using the Wearable Devices Based on EMG Signal for detecting fire (EMG 신호 기반의 웨어러블 기기를 통한 화재감지 자율 주행 로봇 제어)

  • Kim, Jin-Woo;Lee, Woo-Young;Yu, Je-Hun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.3
    • /
    • pp.176-181
    • /
    • 2016
  • In this paper, the autonomous mobile robot control system for detecting fire was proposed using the wearable device based on EMG(Electromyogram) signal. Myo armband is used for detecting the user's EMG signal. The gesture was classified after sending the data of EMG signal to a computer using Bluetooth communication. Then the robot named 'uBrain' was implemented to move by received data from Bluetooth communication in our experiment. 'Move front', 'Turn right', 'Turn left', and 'Stop' are controllable commands for the robot. And if the robot cannot receive the Bluetooth signal from a user or if a user wants to change manual mode to autonomous mode, the robot was implemented to be in the autonomous mode. The robot flashes the LED when IR sensor detects the fire during moving.

Development of H/W and S/W for Detecting Electrical Fire Precursor Signal on Electrical Wirings (배선에서 전기화재 전조신호 검출을 위한 H/W 및 S/W 구축)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.13-18
    • /
    • 2009
  • This paper is purposed to develop DAQ H/W, S/W and DB which can be used in developing electrical fire alarm system or in analyzing electrical fire cause, by detecting and monitoring precursor signals which have high possibility leading to electrical fire on electrical distribution wires. In this paper, developed was DAQ H/W adopting the C8051FXXX CPU which can analyze the measurement signals of current and voltage in electrical distribution wires, other CPU was investigated in view of the best digital sampling rate on the basis of previous researches for electrical fire alarm system. Also, the S/W which can interface with DAQ H/W's communication protocol and can be applied for electrical fire causes analysis, are embodied by LabVIEW. The combined DAQ H/W and S/W could analyze efficiently normal as well as abnormal electrical signals such as RMS value, instantaneous value of current and voltage, frequency signals etc, on the electrical wires. Also, DB system was constructed for recording various analysis results for precursor signals including voltage and current signals. The results by simulator and experiment showed that the suggested scheme with DAQ H/W, S/W and DB in this paper has high usability.