• 제목/요약/키워드: Fire Safety Design

Search Result 683, Processing Time 0.03 seconds

A Study on the Development of Floor-Fixed Standpipe Sway Brace for Narrow Space (협소공간전용 바닥고정형 입상관 흔들림방지버팀대 개발에 관한 연구)

  • Jin, Se-Young;Choi, Su-Gil;Park, Sang-Min;Yeon, Tae-Young;Kim, Chang-Su;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.47-54
    • /
    • 2020
  • This paper proposes a solution to the problems of constructing and installing sway braces for existing standpipes in narrow spaces and pits. The study develops a floor-fixed sway brace for a narrow space that can support the ground area under horizontal seismic loads (X-axis, Y-axis) as well as vertical seismic loads (Z-axis). The results of structural analysis using SolidWorks simulation showed that the eccentric load was generated in the first design according to the anchored position along the vertical direction, and the problem of exceeding the allowable stress of the material along the horizontal and vertical directions. In the second design model, deformation caused by the eccentric load along the vertical direction, similar to the first design model, did not occur. The maximum strain rate was 0.17%, which is approximately 12.84% less than the first design model (Maximum strain rate of 13.01%). It was confirmed that the structural stability and durability improved. Compressive and tensile load testing of the prototypes showed that all of them meet the performance criteria of the standard.

A Study on Seismic Design in the Piping of Water-Based Fire Protection System (수계소화설비 배관계통의 내진 설계기준에 대한 연구)

  • Hur, Man-Sung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.87-90
    • /
    • 2011
  • 본 연구는 수계소화설비 배관계통의 지진시 피해실태 및 내진 성능에 대한 자료를 조사 분석하여 배관계통의 부위별 내진 설계 요구조건을 연구하였다. 수계소화설비 배관계통에 요구되는 내진안전성은 건축물을 사용할 수 있는 상황에서는 기능유지 또는 다소의 손상이 있다고 하더라도 용이하게 복구가 가능한 시스템이어야 한다. 스프링클러설비는 대규모 지진 직후에 있어서도 손상되지 않고 그 기능이 유지되는 것이 요구된다. 수계소화설비 배관계통은 지진에 의한 건축물의 변위 및 배관 본체 등의 과대한 흔들림에 의해 손상을 방지하기위해 건축물의 익스펜션조인트부를 통과하는 배관, 건축물 도입부의 배관, 설비기기와 배관 등의 이음부, 횡주배관, 입상배관, 기기류 등에 내진조치가 요구된다.

  • PDF

Development of a Computer Program to Evaluate Smoke Volume Flow rate and Temperature for Tunnel Fires (터널 화재시 연기발생량 및 온도 예측 프로그램 개발)

  • Park, Won-Hee
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.506-510
    • /
    • 2007
  • Smoke temperature and volume flow rate in a tunnel fire are calculated. To obtain realistic results, enthalpy of smoke which composites combustion gases and entrainment air is calculated from curvefit polynomials by temperature. A user-friendly computer program for them is also developed. This program might be used for a good engineering tool in design of fire safety and mock/reduced-scale fire tests in a tunnel.

A Study of Thermal and Air Distribution Forcast by Firing in the Longitudinal Tunnel (In Yimgo - 4th Tunnel) (종류식 터널내에서 화재에 의한 열 및 기류분포 예측에 관한 연구)

  • Chae, Kyung-Hee
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1209-1212
    • /
    • 2006
  • This study is aimed to analyze the floe patterns and thermal characteristics by computer simulation under the variations of fire strength for Daegu-Pahang Yimgo-4th tunnel, from which flow and heat distributions are predicted In the longitudinal tunnel. Though the results of numerical computations, followings are found; one is that the volume flow rate is discontinuously increasing as closer to fire location, and the other is that a critical design to get faster flow rate is required because of existence of backlayer flow for the high fire strength in view of safety for the people in fire of the tunnel.

  • PDF

Time-Temperature Curve for Fire Safety Assessment of Metropolitan Transit Tunnels (도시철도 터널구조체의 내화안정성 평가를 위한 표준시간-온도곡선 적용)

  • Won, Jong-Pil;Choi, Min-Jung;Lee, Su-Jin;Lee, Sang-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.118-122
    • /
    • 2010
  • The study presents a standard time-temperature curve to evaluate the fire performance of subway tunnel structures. The central subway section is 135km long in Korea, the fourth longest in the world. The number of subway tunnels has been increasing rapidly and fire risk is proportional to the tunnel length. However, an adequate time-temperature curve for subway tunnel fires does not exist. Therefore, we studied a proposed foreign fire design model for which the heat rate is based on the traffic, and we present an appropriate time-temperature curve for Korean subway tunnels. The ISO 834 curve was used as a fire design model and the temperature distribution in the tunnel was estimated using numerical analysis. This led to a proposal for effective measures against subway tunnel fires.

A study on the Means of Egress Codes for Interior Architecture in the United States - Focused on Evacuation Elements in the Interior Architectural Design - (미국의 실내건축 피난 규정에 관한 연구 - 실내건축계획에 있어 피난 요소를 중심으로 -)

  • Kim, Young-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.3
    • /
    • pp.24-32
    • /
    • 2018
  • The law reflects the situation of the times, understands the society, and shows the will of the state and the community. The Means of Egress should be maintained from design to construction, supervision, as well as use, in order to protect the lives and property of the residents as well as the safe use of the facilities. However, Interior Architects are think that evacuation and safety regulations are complex elements that change frequently and may inhibit the idea of design. The purpose of this study is to propose a design method for the use of safe facilities in the interior architectural design on the evacuation regulations affecting the actual design by the IBC(the International Building Code) and NFPA(National Fire Protection Association) LSC (Life Safety Code). The research method is to investigate and analyze the provisions related to the evacuation of interior architecture in the US and to understand the current regulations and the evacuation regulations. We suggest to design method to the details of the hallway, corridors, aisle accessway, door way, exit path, In particular, the design of furniture, tables and chairs layout that could be obstacles to evacuation situations is presented.

A Study on the Risk Assessment of the Underground Space -The Estimation of Smoke Reservoir Screen for Smoke Control in Subway Station Platform (지하공간의 위험성평가에 관한 연구 -지하철 역사내의 연기제어를 위한 제연경계벽의 효용성 평가)

  • Roh Sam-Kew;Hur Jun-Ho
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.103-109
    • /
    • 2004
  • The risk of underground space become an important issue of life safety thought the Taeku subway line Accident. It is essential to study of smoke control screen to minimize the damage of human life because of smoke passage and passenger evacuation routes are on the same vertical and dispersion movement. The Fire modeling result shows the effect of fire control screen can save the evacuation time about 2-2.5 times compare to existing the system However, The designs of fire control screen need to be complied with smoke control ventilation system to present optimum design and the position of installation.

A Study on the Use of Balcony Areas to Improve Fire Escape for Residents in Apartments (화재피난 방안 수립을 위한 공동주택 거주자의 발코니 사용실태 조사)

  • Lee, So-Young;Lee, Myung-Sik
    • Korean Journal of Human Ecology
    • /
    • v.17 no.3
    • /
    • pp.541-552
    • /
    • 2008
  • With the increase of apartments and expansion of balcony areas, fire safety issues are becoming more important. Many researchers have conducted a lot of researches to reduce vertical flame spread in the balcony when an apartment unit is in fire. However, there have rarely been studies to use balcony area as a space for fire escape and evacuation. The study aims to examine the conditions of balcony use in apartments in order to find out prevention elements from fire escape and evacuation, and to investigate residents' satisfaction with balcony. For this study, questionnaires were collected from apartment residents and workers of architectural planning and construction companies. The findings show as follows: first, the balcony is generally used as a storage in each apartment unit nowadays. Second, when fire breaks out, many storage items could disturb residents' safe escape by blocking escape route, and easily promote to spread flame vertically in the balcony.

Upward Flame Spread for Fire Risk Classification of High-Rise Buildings

  • McLaggan, Martyn S.;Gupta, Vinny;Hidalgo, Juan P.;Torero, Jose L.
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.299-310
    • /
    • 2021
  • External fire spread has the potential to breach vertical compartmentation and violate the fire safety strategy of a building. The traditional design solution to this has been the use of non-combustible materials and spandrel panels but recent audits show that combustible materials are widespread and included in highly complex systems. Furthermore, most jurisdictions no longer require detailing of spandrel panels under many different circumstances. These buildings require rapid investigation using rational scientific methods to be able to adequately classify the fire risk. In this work, we use an extensive experimental campaign of material-scale data to explore the critical parameters driving upward flame spread. Two criteria are outlined using two different approaches. The first evaluates the time to ignition and the time to burnout to assess the ability for a fire to spread, and can be easily determined using traditional means. The second evaluates the preheated flame length as the critical parameter driving flame spread. A wide range of cladding materials are ranked according to these criteria to show their potential propensity to flame spread. From this, designers can use conservative approaches to perform fire risk assessments for buildings with combustible materials or can be used to aid decision-making. Precise estimates of flame spread rates within complex façade systems are not achievable with the current level of knowledge and will require a substantial amount of work to make progress.

The Impact of Climate Change on Fire

  • Eun-Hee JEON;Eun-Gu, HAM
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.7 no.4
    • /
    • pp.15-20
    • /
    • 2024
  • Purpose: Climate change is greatly affecting the frequency and intensity of fires around the world. The main effects of climate change on fires are rising temperatures, dry seasons and extreme droughts, changes in precipitation, increased strong winds, extended fire danger periods, and changes in natural ecosystems. Several factors due to climate change are increasing the risk of large-scale fires, such as wildfires. Research design, data and methodology: Rising temperatures caused by climate change will make forests and grasslands drier, make it easier for wildfires to occur in drier environments and spread quickly to wider areas, and the generated wildfires will release large amounts of greenhouse gases into the atmosphere, such as carbon dioxide (CO2), and the released greenhouse gases will strengthen the global greenhouse effect, further raising the temperature. As temperatures rise, the risk of wildfires increases in drier environments, and this process is repeated, leading to a vicious cycle of intensifying climate change as more fires occur and more greenhouse gases are released. Results: In conclusion, climate change is increasing the risk of fire occurrence and this phenomenon is expected to become more frequent and severe in the future. Conclusions: In order to cope with the increasing fire risk caused by climate change, fire prevention and management. Fire detection and response systems need to be strengthened, supportive policies and international cooperation are needed to restore ecosystems, and these measures, along with fire prevention, management and countermeasures, should take into account long-term climate change and adaptation as well as short-term responses.