• Title/Summary/Keyword: Fire Safety Design

Search Result 676, Processing Time 0.024 seconds

Evaluation to Collision Safety Performance of Stacking Angle Different CFRP/Al Circular Member (적층각이 다른 CFRP/Al 혼성 원형부재의 충돌안전성능 평가)

  • Yang, Yong Jun;Kim, Young Nam;Cha, Cheon Seok;Jung, Jong An;Yang, In Young
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.1-6
    • /
    • 2015
  • The actual condition is that environmental pollution due to the development of various industries has recently become a serious issue. An interest in improving the gas mileage is rising due to an increase in the number of vehicles in the era of high oil price in particular. In order to solve this problem, priority should be given to light-weight design of car body, However, at present, a design method enabling the conventional steel plate to be replaced is direly needed in order to guarantee passengers' safety according to excessive light-weight design of car body. In this study, in order to apply a design method that could realize fuel savings and environmental pollution prevention through an improvement in gas mileage together with meeting the safety requirements for vehicles, it was supposed that CFRP/Al composites member would be used as primary structural member. And to this end, it was intended to obtain optimum design data by experimentally implementing external impulsive load applied to the car body. According to results of impact test of CFRP/Al composites member, a collapsed shape of folding, crack, and bending occurred. So, it was possible to find that energy was observed. And in case of specimen having an angle of $90^{\circ}$ in the outermost layer and stack sequence of $[90^{\circ}{_2}/0^{\circ}2]s$, its collapsed length was shown to be short. Therefore, it was possible to find that the absorbed energy was shown to be higher by 20% or above at the maximum.

Knowledge Modeling of Reliability Analysis and Safety Design for Offshore Safety Instrument System with MBSE (Model-Based Systems Engineering) (모델기반 시스템엔지니어링을 활용한 해양플랜트 안전시스템(SIS, Safety Instrumented System)의 신뢰도 분석 및 안전설계 지식 모델링)

  • Bae, Jeong-hoon;Jung, Min-jae;Shin, Sung-chul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.3
    • /
    • pp.222-235
    • /
    • 2018
  • The hydrocarbon gas leak in the offshore plant can cause large accidents and lead to significant damages to human, property and environment. For prevention of fire or explosion accidents from gas leak, a SIS(Safety Instrumented System) should be installed. In the early stage of the offshore design, required SIL(Safety Integrated Level) is determined and reliability analysis is performed to verify the design in reliability aspects. This study collected data, information related to reliability analysis and created knowledge model of safety design for the offshore system with MBSE(Model-Based Systems Engineering) concept. Knowledge model could support safety engineer's design tasks as the guidance of reliability analysis procedure of safety design and make good conversation with other engineers in yard, class, company, etc.

A Survey on Present Condition of Fire Safety Management of Elderly care Facilities for Evacuation Safety Design (피난안전설계를 위한 노인요양시설의 소방안전관리 실태 조사)

  • Hong, Hae-Ri;Seo, Dong-Goo;Kim, Dong-Eun;Kwon, Young-Sook;Park, Hyun-Sik;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.272-275
    • /
    • 2011
  • 본 연구는 고령자시설의 현황과 고령자의 군집보행속도를 조사한 전보에 이어 고령자를 고려한 피난안전설계를 위한 기초연구로서 노인요양시설의 근무자의 소방안전관리실태에 관한 설문조사를 실시 및 분석하였으며 그 결과 화재시 재실자의 피난가능여부와 소방서와의 연락체계에 관한 질문에서 초기피난의 문제점을 도출할 수 있었으며 노인요양시설의 비상구 및 주야간 상시 관리자 수 및 피난시설에서 대응책이 필요할 것으로 사료되어 향후 체계적인 피난안전계획의 구축이 필요할 것으로 판단된다.

  • PDF

A Study on the Hazard and Risk Analysis of Hospital in Korea - Focused on Local Medical Centers (의료기관의 위험도 분석 조사 - 지역공공의료원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon;Lee, Hyunjin;Kim, Taeyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.31-39
    • /
    • 2022
  • The purpose of this study is to analyse the hazard risk by examining the magnitude and severity of each type of hazard in order to mitigate and prepare for disasters in medical facilities. Methods: The hazard risk analysis for hazard types was surveyed for team leaders of medical facilities. The questionnaire analyzed data from 27 facilities, which were returned from 41 Local Medical Centers. Results: When looking at the 'Risk' by category type of hazard, the influence of health safety and fire/energy safety comes first, followed by natural disaster, facility safety, and crime safety. On the other hand, as for 'Magnitude', facility safety and crime safety come first, followed by health safety, fire/energy safety, and natural disasters. Most of the top types of disaster judged to have high hazard in medical facilities are health types. The top five priorities of hazard in medical facilities, they are affected by the geographical and industrial conditions of the treatment area. In the case of cities, the hazard was found to be high in the order of infectious disease, patient surge, and wind and flood damage. On the other hand, in rural areas, livestock diseases and infectious diseases showed the highest hazard. In the case of forest areas, the hazard was high in the order of wildfire, fire accident, lightning, tide, earthquake, and landslide, whereas in coastal areas of industrial complexes, the hazard was high due to fire, landslide, water pollution, marine pollution, and chemical spill accident. Implications: Through the research, standards will be established for the design of hospitals with disaster preparedness, and will contribute to the preparation of preemptive measures in terms of maintenance.

A Study on the Pattern Development for Forest Fire Safety Clothing (산불진화용 안전복 패턴 개발을 위한 연구)

  • Choi, Mee-Sung
    • Fashion & Textile Research Journal
    • /
    • v.13 no.4
    • /
    • pp.624-634
    • /
    • 2011
  • The purpose of this study is to develop the pattern of safety clothes used at flat or mountainous areas and to identify the pattern of safety clothes by conducting experimental evaluation of virtual wear. Three subjects were selected, based on fire fighters' physical constitution. A prototype design for safety clothing was determined after in-depth interviewing of professionals and surveying of Forest service staff and related agency. Wearing test should be carried out in the order of pattern making, virtual and real wearing evaluation. For data analysis, technical statistical values should be obtained by using body measurements of subject, frequency analysis and T-test. The jacket is designed to have a front extension and the entire length of clothing enough for wearer to put on it over ordinary shirts or sweater. The collar of jacket is of round type. Cyber reality enables to identify the movement and activity of virtual fitting model and to find out errors or problems in safety clothing prior to on-the-spot wear test, thus raising the precision level of pattern. There was significant difference between real and virtual fit preference. The results show that the virtual try-on system need the development of a specific style.

Study on the Reliability Analysis of Wood Floor System Exposed to Fire (화염에 노출된 목재 마루 시스템의 신뢰성 해석에 관한 연구)

  • Kim, Gwang-Chul;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.66-74
    • /
    • 2004
  • Fire performance is the important criterion for evaluating of safety of wood structures which exposed to the standard fire condition. Endurance time and time-to-failure are used as the criteria for fire performance in many countries. Reliability analysis about wood floor system which exposed to fire was carried out as preliminary research for reliability-based design on fire. Analyses were conducted by two methods, numerical analysis method and deterministic method.. They didn't show the difference between two methods. The reliability of floor exposed to fire showed strong dependence on the coefficient of variation of member and did not be influenced by the strength or load of member.

Distribution of Heat and Smoke Related to Openings in Hise-Rise Apartment Building Fires (고층 공동주택의 개구특성에 따른 화재시 열.연기유동에 관한 연구)

  • 이지희
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.59-79
    • /
    • 2001
  • The paper proposes alternatives for fire safety in architectural planning through heat-smoke distribution related to openings so that we decrease casualty and property loss by fire and lay a great emphasis on building high-rise apartments with consideration of fire safety in Korea. An analysis program(HFA-Heat Fluid Analysis) is built to perform simultaneously numerical analysis and experimental analysis on rooms, units and buildings. In consequence, on the first, fire prevention methods are required to be set up related to openings for design rooms since the flow of heat and smoke is influenced by the type of openings in high-rise apartments. Second, the numerical analysis showed that different planning types cause to show differences in the spreading time of heat and smoke to design the units of high-rise apartments. On the third, each unit building showed different fire behavior depending on openings by numerical analysis and small scaled experiment on heat and smoke flow.

  • PDF

Progressive collapse of steel-framed gravity buildings under parametric fires

  • Jiang, Jian;Cai, Wenyu;Li, Guo-Qiang;Chen, Wei;Ye, Jihong
    • Steel and Composite Structures
    • /
    • v.36 no.4
    • /
    • pp.383-398
    • /
    • 2020
  • This paper investigates the progressive collapse behavior of 3D steel-framed gravity buildings under fires with a cooling phase. The effect of fire protections and bracing systems on whether, how, and when a gravity building collapses is studied. It is found that whether a building collapses or not depends on the duration of the heating phase, and it may withstand a "short-hot" fire, but collapses under a mild fire or a "long-cool" fire. The collapse time can be conservatively determined by the time when the temperature of steel columns reaches a critical temperature of 550 ℃. It is also found that the application of a higher level of fire protection may prevent the collapse of a building, but may also lead to its collapse in the cooling phase due to the delayed temperature increment in the heated members. The tensile membrane action in a heated slab can be resisted by a tensile ring around its perimeter or by tensile yielding lines extended to the edge of the frame. It is recommended for practical design that hat bracing systems should be arranged on the whole top floor, and a combination of perimeter and internal vertical bracing systems be used to mitigate the fire-induced collapse of gravity buildings. It is also suggested that beam-to-column connections should be designed to resist high tensile forces (up to yielding force) during the cooling phase of a fire.

A Study on Plan for Introduction of Fire Influence Evaluation System through Risk Assessment of the Urban Lifestyle Housing Buildings (도시형 생활주택의 위험성 분석을 통한 화재영향성평가제도의 도입방안에 관한 연구)

  • Kim, Dong-Wook;Baek, Sona;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.10-17
    • /
    • 2017
  • Securing fire safety using only fire-fighting facilities is difficult because causes of modern fire vary, such as architectural structures and building use patterns. In order for fire safety to be guaranteed by enacting and revising fire regulations reflecting the fire hazard characteristics and user's characteristics, the introduction of fire influence evaluation (fire risk assessment) system needs to be considered in a timely manner to be adopted but unfortunately two attempts before have failed. In this study, a fire case of urban lifestyle housing was surveyed to introduce a fire influence evaluation system and a field survey on the actual condition of the 414 urban lifestyle housing buildings and fire & evacuation simulation results of one representative building in Suyoung-gu and Nam-gu District of Busan Metropolitan City were analyzed. The necessity, procedures and implementation method of fire influence evaluation system were questioned and tested by the professional fire experts, fire officers and firefighters and architects. On the basis of these facts, introduction of (fire influence evaluation system) should be absolutely adopted and the fire department and fire regulation are eligible to implement the system. Therefore, fire regulation needs to be enacted or revised in accordance with the new fire environment and fire safety system that needs to be built up. Accordingly, aggressive promotion through public hearings on the necessity of fire impact assessments, consensus among departments and fostering experts to carry out fire influence evaluation system will be the core.

A Study on Performance-Based Design Enforcement (성능위주설계 시행의 개선방안)

  • Lee, Yang-Ju;Ko, Kyoung-Chan;Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.68-73
    • /
    • 2012
  • Performance-based design (PBD) for large scale high rise buildings has been enforced to secure fire and evacuation safety since July 1, 2011. As various types of trial and error were expected in the early stage, to suggest solutions to the problems that might be followed by the enforcement, the regulations on PBD were reviewed and a questionnaire survey to fire protection specialists was carried out. It was confirmed that PBD is required for large scale apartment buildings, and specific and detail criteria for PBD methodology and evaluations, education for PBD to personnel who design and evaluate are also in need.