• Title/Summary/Keyword: Fire Safety Control

Search Result 426, Processing Time 0.028 seconds

A Study on Smoke Movement by Using Large Eddy Simulation II. Smoke Control Systems and Opening Size (대와류모사를 이용한 연기이동의 연구 II. 제연방식과 개구부의 크기)

  • 박외철
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.34-38
    • /
    • 2003
  • The large eddy simulation based Fire Dynamics Simulator was utilized to investigate the effects of the size of an opening on smoke removal performance for the three smoke control systems-ventilation purge, and extraction. Three different opening sizes, $r_A$=1, 2, and 3 were investigated while the flow rate remained 0.75 $m^3/s$ at the inlet or outlet depending on the systems. Increase of the opening size did not give a significant difference in the smoke removal rate for the three smoke control systems, though the increasing opening size slightly improved smoke removal. The extraction system was shown the best smoke control system, and the purge system yielded low performance compared to the other two systems for all the different opening sizes.

Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire (고양종합터미널화재 시 소방시설의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.95-107
    • /
    • 2018
  • This study analyzed the working conditions of the fire protection system in the Goyang Bus Terminal fire based on the fire investigation results. The results were as follows. First, extinguishing using an indoor fire hydrant was not attempted immediately after the fire burned the ceiling urethane foam. Second, a sprinkler alarm valve was turn off and did not work in the repair work space of the 1st basement. On the other hand, the sprinklers in the $2^{nd}$ basement, $1^{st}$ floor, $2^{nd}$ floor, and $3^{rd}$ floor worked and prevented the fire from moving to stories other than the $1^{st}$ basement. Third, although an exit light worked normally, it was not installed in the exit from the waiting room in the $2^{nd}$ floor to the bus stop. This resulted in many casualties. Fourth, although a fire receiver sent an electrical signal to the fan controller of the smoke control system, it was treated manually in the fan controller and the fan in the $2^{nd}$ floor did not work.

A Study on the Essential Information to Collect Disaster Sites for Effective Disaster Management : Focused on Jecheon Sports Center Fire case (효율적인 재난 상황관리를 위한 재난현장 필수정보 연구: 제천 스포츠 센터 화재사건을 중심으로)

  • Cho, Jung-Yun;Song, Ju-Il;Jang, Moon-Yup;Jang, Cho-Rok
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.70-78
    • /
    • 2020
  • Purpose: When a disaster occurs, information is collected and sent indiscriminately to the disaster safety situation room, making it difficult to make quick and correct decisions. Therefore, in this study, both the field response team and the situation room attempted to derive the essential information elements for disaster management so that they can identify and respond optimally. Method: In this study, the actual disaster response process was first identified based on the case of large-scale fire disasters in multi-dense facilities. Afterwards, essential information on disaster management was obtained by analyzing the standard manual for large-scale fire crisis management in multi-dense facilities and the fire situation report form prepared at the time of disaster. Result: The Essential information on disaster management was divided into four stages: situation reception·reporting·transmission, total response·regional emergency rescue control group·regional disaster safety task force, operation stage of central emergency rescue control group·central disaster safety task force, and recovery stage. Since then, the information to be collected at each stage and the information relevant to core tasks are presented. Conclusion: The Essential information on disaster management thus obtained can serve as a guide for the person who collects information on site to collect information efficiently. In addition, it is expected that the situation room in charge of disaster response decision-making will receive only the information necessary for decision making, so that it is possible to make a quick situation decision and more efficient disaster situation management.

Report of Eight Unrecorded Fungi from the Fire Blight Burial Control Soil in Korea (과수화상병 매몰방재지 토양에서 분리된 8종의 국내 미기록 진균 보고)

  • Hyeongjin Noh;Huiju Seo;Seong Hwan Kim
    • The Korean Journal of Mycology
    • /
    • v.51 no.4
    • /
    • pp.447-460
    • /
    • 2023
  • Fire blight, a plant disease caused by Erwinia amylovora, continues to cause considerable damage to fruit-bearing trees belonging to the Rosaceae family, such as apples and pears. In Korea, to hinder its rapid spread diseased apple and pear trees have been buried since its first occurrence. To determine the safety of this control method, the buried plant materials and adjacent soil have been investigated. In the process of investigating the microbiota of the buried soil, Bisifusarium allantoides, Botryotrichum domesticum, Microascus verrucosus, Paraphoma pye, Phaeosphaeria culmorum, Ramophialophora globispora, Sordaria tomentoalba, and Striaticonidium brachysporum were identified as unrecorded species in Korea. To report the above eight species as Korean unrecorded species, we report their morphological and molecular features in this study.

Process Development of a Standard Operating Procedure (SOP) for the Manufacturing of Standardized Distribution Boards (규격화된 분전반 제작을 위한 표준작업절차(SOP)의 공정 개발)

  • Ko, Wan-Su;Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.21-27
    • /
    • 2018
  • The purpose of this study is to develop a SOP (Standard Operating Procedure) for a distribution board that can monitor the leakage current of a load distribution line in real time. The developed distribution board was fabricated by applying IEC 61439-1. It consists of the distribution board and an alarm device. The work process for making the distribution board was compliant with the KEMC (Korea Electrical Manufacturers Cooperative) regulations. And the AC distribution board range is 1,000 V. In addition, the voltage in DC is less than 1500 V. The distribution board receives a 3-phases and 4-wires power supply system and can supply power to the load of a maximum of 32 single or three phase distribution circuits. Also, leakage current measured on the power distribution board was used by sensors installed. The SOP of the developed distribution board consists of the installation standards for the short circuit alarm device and sensor, the surge protection device, switches and indication lamps, and other devices. The operation procedure was prepared so that each manufacturing step of the distribution board must be confirmed by the persons in charge of preparation, production, quality control and approval before moving forward to the next step.

A Study on Risk and Safety measures of the Improved Explosive Device (사제폭발물의 위험성 및 안전대책에 관한 연구)

  • Han, Jae-Hoon;Choi, Min-Ki;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.193-202
    • /
    • 2014
  • Crimes with explosives is one of the mass-destructive crimes that involves the most victims. It is heavily punished under the Korean laws. Mid-eastern area is one of the leading places that are home to improvised explosive device attacks, in the form of religious or political terrorism because of its convenience of use, production and disguise. Improvised bombs are permeating into domestic crimes in Korea as their tools. Use of explosive substances are strictly restricted in this country, but it is not impossible to find its information online and to create private explosives with a bit of interest. And they are being traded in the grey market. For this reason, this thesis offers the method of an efficient safety control of explosive substances, which can be used as raw materials for improvised explosive devices, in order to protect citizens' lives and properties and to promote national security down the road.

Study on the Causes of Malfunctions of PCBs Applied to the Power Saving Mode of Electrical Systems and its Solution (전기시스템의 절전모드에 적용되는 PCB의 오작동 원인 개선에 관한 연구)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.51-55
    • /
    • 2013
  • The purpose of this study is to find the causes of malfunctions and defective operation of printed circuit boards(PCBs) built into home refrigerators to perform power saving functions. This study performed an electrostatic test of a PCB built-in using an Auto Triggering system; lightning and impulse tests using an LSS-15AX; and an impulse test using an INS-400AX. From the analysis of a secondarily developed product, it was found that electrostatic discharge(ESD) caused more malfunctions and defective operations than electric overstress(EOS) due to overvoltage. As a result of increasing the condenser capacity of the PCB circuit, withstanding voltage was increased to 7.4 kV. In addition, this study changed the power saving mode and connected a varistor to the #2 pin of an IC chip. As a result, the system consisting of all specimens of a finally developed product was operated stably with an applied voltage of less than 10 kV. This study found it necessary to perform quality control at the manufacturing stage in order to reduce the occurrence of electrostatic accidents to IC chips built into a PCB.

A Study on the Range of Damage Effects of Benzene Leakage Accidents using the KORA Program (KORA 프로그램을 활용한 벤젠 누출사고 피해영향범위에 관한 연구)

  • Cha, Jeong-Min
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.112-120
    • /
    • 2019
  • Benzene is a class 4 hazardous material according to the Act on the Safety Control of Hazardous Substances. This study qualitatively evaluated the damage size of a "toxic" accident and "pool fire" accidents based on benzene in a virtual scenario of a fire and leakage accident during unloading at a port facility. The KORA program was used as an evaluation method, which is supported as a universal program by the National Institute of Chemical Safety. The range of damage effects of a benzene-induced fire and leakage accident was predicted. In the case of toxic damage range, the accident's damage effect range for the "worst case scenario" was reduced by up to 5.11% with a decrease in the size of the leakage hole. In the case of the leakage time, the damage effect range increased to 145.12% with a 10 min leakage time compared to that of a 5 min leakage time and went up to 20 min (212.29%) with a 20 min leakage time. In the case of pool-fire-induced damage, the damage effect range by radiant heat in the "worst case scenario" was 228.8 m in radius from the center of the handling facility. In the "alternative scenario," the damage effect range by radiant heat was reduced by up to 8.26% compared to that in the "worst case scenario" since the size of the leakage hole was decreased by reducing the cross-sectional area of the pipe.

A Study on the Implement of AI-based Integrated Smart Fire Safety (ISFS) System in Public Facility

  • Myung Sik Lee;Pill Sun Seo
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.225-234
    • /
    • 2023
  • Even at this point in the era of digital transformation, we are still facing many problems in the safety sector that cannot prevent the occurrence or spread of human casualties. When you are in an unexpected emergency, it is often difficult to respond only with human physical ability. Human casualties continue to occur at construction sites, manufacturing plants, and multi-use facilities used by many people in everyday life. If you encounter a situation where normal judgment is impossible in the event of an emergency at a life site where there are still many safety blind spots, it is difficult to cope with the existing manual guidance method. New variable guidance technology, which combines artificial intelligence and digital twin, can make it possible to prevent casualties by processing large amounts of data needed to derive appropriate countermeasures in real time beyond identifying what safety accidents occurred in unexpected crisis situations. When a simple control method that divides and monitors several CCTVs is digitally converted and combined with artificial intelligence and 3D digital twin control technology, intelligence augmentation (IA) effect can be achieved that strengthens the safety decision-making ability required in real time. With the enforcement of the Serious Disaster Enterprise Punishment Act, the importance of distributing a smart location guidance system that urgently solves the decision-making delay that occurs in safety accidents at various industrial sites and strengthens the real-time decision-making ability of field workers and managers is highlighted. The smart location guidance system that combines artificial intelligence and digital twin consists of AIoT HW equipment, wireless communication NW equipment, and intelligent SW platform. The intelligent SW platform consists of Builder that supports digital twin modeling, Watch that meets real-time control based on synchronization between real objects and digital twin models, and Simulator that supports the development and verification of various safety management scenarios using intelligent agents. The smart location guidance system provides on-site monitoring using IoT equipment, CCTV-linked intelligent image analysis, intelligent operating procedures that support workflow modeling to immediately reflect the needs of the site, situational location guidance, and digital twin virtual fencing access control technology. This paper examines the limitations of traditional fixed passive guidance methods, analyzes global technology development trends to overcome them, identifies the digital transformation properties required to switch to intelligent variable smart location guidance methods, explains the characteristics and components of AI-based public facility smart fire safety integrated system (ISFS).

Risk Perception of Fire Fighters Responsible for Nuclear Power Plants : A Concept Mapping Approach (원자력발전소 관할 소방관의 위험인식 개념도 연구)

  • Choi, HaeYoun;Lee, SongKyu;Kim, MiKyong;Choi, Jong-An
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.141-149
    • /
    • 2018
  • The perception of risk that firefighters have is closely related to their performance and emergency preparedness in nuclear power plant accidents. This study investigated the unique risk perception among firefighters working in nuclear power plants (NPPs) using a concept mapping method. Thirty three firefighters in NPPs participated in this study. Two core axes, "fear and control" and "coping resource", emerged in the firefighters' risk perception. In particular, the risk perception consisted of six clusters: fear of radiation exposure and low controllability; anxiety caused by the lack of control and authority; lack of trust and cooperation; lack of authority and professionals; lack of equipment, manual, and information; and lack of knowledge and training. Catastrophic expectation and a low sense of control caused by the lack of responsive resources were the main factors that increase the risk perception. The theoretical and practical contributions of this study were discussed.