Use of Fuzzy Set Theory in the Inspection of Transmission Lines of Nuclear Installations

  • Durpel, L.Van-den;D.Ruan;P.D hondt
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1066-1069
    • /
    • 1993
  • The presence of older installations, in particular nuclear facilities, demands extra studies concerning the safety evaluation of those installations. One of the aspects to deal with is the safety of the several transmission lines in a nuclear installation, for instance the safety of control, safety against fire, etc.. . This paper investigates the use of fuzzy set theory in the inspection of transmission lines of nuclear installations at SCK/CEN, Belgium.

  • PDF

A Numerical Study on Effects of Flow Through Openings on Convection (개구부의 유동이 대류에 미치는 영향에 관한 수치연구)

  • 박외철;이경아
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.52-56
    • /
    • 2000
  • The finite control volume method was utilized to investigate the effects of flow through openings on convection in an enclosure. Flow patterns and temperature distribution were compared for non-dimensional inflow velocity U=20, 40, 60 at Ra=$10^4$ and $5\times10^4$, respectively. The inflow velocity influenced temperature distribution in the enclosure significantly and lowered temperature on the top wall. The flow through openings forced the position of the highest temperature on the top wall to move toward the outflow opening.

  • PDF

Analysis of Thermal Characteristic for Wiring at Heater Connector of Semiconductor Chiller Equipment (반도체 공정 칠러 장비의 히터 접속부 전기배선에 대한 열적 특성 분석)

  • Gyu Bin Kim;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.27-34
    • /
    • 2023
  • With the technological development of the semiconductor industry, the roles of electrical and thermal energy supply and control of semiconductor equipment in ultrafine processes have become very important. However, instances of electrical fires in the chiller heater, which is used for cooling in the semiconductor manufacturing process, are increasing. A fire occurs in combustibles due to high heat at the connection part of the chiller heater, that is, when the number of electrical wires in the connection part is reduced or when the wires are completely disconnected. In this study, the temperature characteristics were compared and analyzed through experiments and 3D simulations. The number of electrical wires, which is the connection part of the chiller heater, was reduced by 90%, 50%, 30%, 10%, and 5%, and the wires were completely disconnected. When the number of electrical wires was reduced by 5%, heat of up to 80℃ was generated, which is a relatively high temperature but insufficient to cause a fire in combustibles. Complete disconnection occurred due to the vibration of the motor and other components, and sparks and arcs were generated, resulting in a rapid increase in temperature to up to 680℃. When completely disconnected, the temperature increase was sufficient to cause a fire in the combustibles covering the terminal block. Therefore, in this study, the causes of electrical fires in chiller heaters were investigated and preventive measures were proposed by analyzing abnormal signals and thermal characteristics caused by the electrical wiring being reduced and completely disconnected.

Smoke Control Performance of a Serial Structure Using "CONTAM" (CONTAM을 이용한 직렬형태 구조의 제연성능 구현에 관한 연구)

  • Kim, Mi-Seon;Seo, Dong-Gil;Gu, Seon-Hwan;Yoo, Young-Min;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.53-62
    • /
    • 2019
  • A recent trend shows that more buildings are being constructed as mixed-use (residential and commercial) properties for efficient land use. This has led to an increased frequency in the occurrence of fires and the associated potential risks. In particular, in case of high-rise apartments, at least one of the elevators in each building is installed for evacuation purposes separately from the emergency elevator; therefore, for a combined ancillary room and emergency elevator platform situation, the structure is inevitably in series with the evacuation elevator platform. Thus, a proposal for a new type of ventilation zone based on existing national fire safety codes is required to achieve smoke control performance. To this end, the air egress velocity and differential pressure of each ventilation zone are checked using the "CONTAM" software; further, an alternative is proposed to secure smoke control performance for series structures.

A Numerical Study for the Atrium Smoke Control by Fire Shutter and Evacuation (방화셔터를 이용한 아트리움 제연과 피난안전에 관한 수치해석 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.50-59
    • /
    • 2010
  • Four fire scenarios, as the cases of fire sizes of 2 MW and 5 MW, and no installation and activation of atrium fire shutter for dormitory building of Daegu 'D college', were developed and fire simulations were run using FDS (ver. 5.5.0) and Pathfinder 2009 programs. By assessing fire and evacuation, the effects of atrium fire shutter and vents on the smoke control of atrium were evaluated and this study also analyzed fire hazard and egress safety for occupants in the dormitory. Fire shutter's preventing smoke transport around atrium was much effective, but smoke layer descended down the design limit of smoke height and kept about 2 m height from the atrium floor in all cases because flow rate through vents was not enough. For the case of 5 MW fire and no fire shutter, fire hazard was higher due to visibility than temperature and allowable egress time to stairwell was short less than 5 seconds for the occupants on the floors of 4F to 7F. For total occupants, egress time out of main doorway was calculated about 136 seconds. It is sure that additional systems improving the performance of smoke control need to be installed for more safe evacuation.

Smoke Movement Characteristics in the Ship's Indoor Spaces with Fire Size and Location (선박 실내공간에서 화재의 크기 및 위치에 따른 연기거동특성)

  • Han, Won-Hui;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.11 no.1 s.22
    • /
    • pp.53-59
    • /
    • 2005
  • It is very dongerous for ship‘s fire which occurs from navigating because of it will not be able to expect fire fighting from land so that handle with the oneself to control. Additionally, in the case of passenger ship is more serious for the reason of not only the property damage but also large life accident can be occurred continuously. When the fire occurs, the many smoke to occur simultaneously as well as the heat from combustion process and the poisonous smoke is brought the life damage as the death from suffocation The purpose of this study is to examine the smoke movement characteristics in the ship's indoor spaces with fire size and location An experimental study was carried out with two sized of fires and three typed of fire source locations. As the results, the smoke and heat diffusion characteristics Ms been showed the most quick rise curve in the case of comer type fire.

  • PDF

A study on the application of improved IoT- based smoke control system to lodging facilities fires (개선된 IoT기반 제연시스템의 숙박시설 적용에 관한 연구)

  • Kim, Suyong;Lee, Sangsoo;Lee, Sung-Hwa;Kim, Jin-Tae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.5
    • /
    • pp.113-118
    • /
    • 2021
  • The study is to provide safety to the occupants from smoke generated by fire occurring at midnight, and to provide a method for providing evacuation safety for a certain period of time even if the occupants are not aware of the fire. The goal of this study is to occur in small accommodation (floor area less than 1,000m2)It is to design a system that can provide ASET for more than 1 hour even if the occupant does not recognize the fire in late-night fire. The basic structure of the smoke-control system applicable to accommodation facilities was designed, and the expected effect was suggested when applied to small-scale domestic accommodation facilities through evacuation scenarios in accommodation facilities to which the system was applied.

A Study on Electric Safety Control Device for Prevention of Over Current and Short Circuit Faults (과전류 및 단락사고 방지용 전기안전 제어장치에 관한 연구)

  • Jo, Si-Hwan;Kwak, Dong-Kurl;Jung, Do-Young;Shim, Jae-Sun;Kim, Jung-Sook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2100-2101
    • /
    • 2008
  • This paper is studied on a protective control system for electrical fire and electrical faults due to over current or electric short circuit faults by using electrical thermal characteristics of PTC (Positive Temperature Coefficient) thermistor and current response characteristics of high sensitive reed switch. The PTC thermistor has characteristic of positive resistivity temperature coefficient according to the temperature variation, which is construction of a regular square and cube demarcation with BaTiO3_Ceramics of positive temperature coefficient. Also PTC thermistor shows the phenomenon which is rapidly increased in the resistivity if the temperature is increased over Curie temperature point, and reed switch, which is used for electrical fault current sensing devices, have a excellent characteristic of response velocity in degree of ${\mu}s{\sim}ms$ that sensing magnetic flux in proportion to dimension of line current. This paper is proposed on a protective control system use PTC thermistor and reed switch for sensor which is protected from electrical fire due to overload faults or electric short circuit faults. Some experimental results of the proposed electric safety control device are confirmed to the validity of the analytical results.

  • PDF

Analysis of an Automotive Fire Case that a Fire Broke out during Driving Immediately after DPF Cleaning (DPF 클리닝 직후에 주행 중 발생한 승용차화재 사례의 분석)

  • Lee, Euipyeong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.5
    • /
    • pp.556-565
    • /
    • 2016
  • As a result of the enforced control of emission, many devices, including the diesel particulate filter, have been installed in diesel cars to reduce the emission of particulate matters. In this study, a car fire case has been investigated and analyzed. A car fire broke out after the vehicle traveled a distance of 1.4 km from a car service center. The car was provided with DPF cleaning when the DPF warning light came on. After being dismantled in the engine room, the car's engine and gearbox were investigated. The findings showed that the rear part of the DPF metal case was melted and punctured, while the honeycomb filter of the DPF was damaged. The car fire was caused by an overheated DPF associated with inaccurate maintenance practice. Therefore, the responsibility of the fire rested on the car service center that performed the DPF cleaning.

Numerical Simulation on Smoke Movement in Multi-Compartment Enclosure Fires under Pressurized Air Supply Conditions (급기가압 조건에서 복합 구획 공간 화재의 연기 거동에 대한 수치해석 연구)

  • Ko, Gwon Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.15-21
    • /
    • 2018
  • This study examined the flow characteristics of fire smoke under pressurized air ventilation conditions by carrying out fire simulations on multi-compartment enclosure, including room, ancillary room and stair case. Fire simulations were conducted for the air-leakage test facility, which was constructed to measure the effective leakage area and aimed to improve the understandings of fire and smoke movement by analyzing the overall behaviors of fire smoke flow and pressure distributions of each compartment. The simulation results showed that the heat release rate of the fires was controlled sensitively by the amount of air supplied by the ventilation system. An analysis of the velocity distributions between the room and ancillary room showed that fire smoke could be leaked to the ancillary room through the upper layer of the door, even under pressurized air supply conditions. From these results, it was confirmed that the fire size and spatial characteristics should be considered for the design and application of a smoke control system by a pressurized air supply.