• 제목/요약/키워드: Fire Risk Analysis

검색결과 502건 처리시간 0.024초

안전성 향상을 위한 도로터널 등급에 관한 연구 (A Study of Classification of Road Tunnel for Fire Safety)

  • 유지오;이동호;신현준
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.112-119
    • /
    • 2005
  • In road tunnel, in order to prevents an accident and minimize the damage of an accident in the case of fire, safety facilities and equipments are integral parts. The type and amount of safety facilities are based on tunnel type and length, traffic flow rate, etc. Therefore many countries use a tunnel classification system that categories tunnel into groups, and specifies the necessary emergency equipment for each group. In this study, for the purpose of classifying tunnel based on tunnel ist investigated the domestic and foreign standards and regulations for safety of road tunnel. As a results, we suggest the method of classification of tunnel by traffic performance, tunnel grade, the volume of traffic, fraction of HGV, rules or regulations for transports of dangerous good through tunnel.

소방공무원들의 현장 활동 시 석면노출의 위험성과 대응방안 (The Risk and Countermeasures of Asbestos Exposure at the Scene Activities of Fire Officials)

  • 이정일
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.68-78
    • /
    • 2010
  • 본 연구의 목적은 소방공무원들이 현장 활동 중에 석면함유 비산먼지로 위협되고 있는 현상에 대한 심각성을 사례 및 설문을 통해 발생 원인을 찾아 현장 활동 중에 석면노출을 효과적으로 예방하는데 있다. 소방관들의 현장 활동과 석면분진의 위험성에 대한 상관관계를 설문조사를 하여 분석하고 석면으로 인해 발생하는 석면폐암, 악성중피종과 같은 질병으로부터 소방공무원을 보호하고, 불합리한 여건들을 변화시킴으로써 조직운영의 최적화와 안전하고 쾌적한 근무여건을 통하여 소방공무원들이 현장 활동에서 치명적인 위해요소를 사전에 제거 하거하고자 한다. 또한 석면노출 기준에 따른 보호 장비 착용으로 철저한 소방 활동을 강화함은 물론, 소방 활동상 유해성인자의 심각성을 인식하고, 질환 피해보상에 대한 법적 제도를 마련하여, 아직까지 인정되고 있지 않은 질병에 대한 공무상 재해인정을 통한 제도적 미비점을 보완하여, 소방공무원의 사기진작 및 근무여건개선으로 대 국민 서비스 향상 등을 기대하고자 한다.

Systematic Review and Meta-Analysis of Efficacy and Safety of Fire Needling and Warm Needling on Acute Gout

  • Ji Hye Hwang;Aejin Song;Ho-Sueb Song
    • 대한약침학회지
    • /
    • 제25권4호
    • /
    • pp.301-316
    • /
    • 2022
  • Objectives: This study aimed to evaluate the efficacy and safety of heat stimuli (e.g., fire needling, warm needling) in acupuncture for acute gout. Methods: Four international online databases (PubMed, Cochrane, Embase, and Chinese National Knowledge Infrastructure) were searched to identify randomized, controlled trials (RCTs) that used fire needling and warm needling for acute gout. The methodological quality of the RCTs was evaluated using the Cochrane risk-of-bias (RoB) tool. Thirteen RCTs (840 patients) were included and analyzed. Three evaluation tools (total effective rate, uric acid level, and pain score) were mainly used. Comparisons were made between Western medicine (WM) and i) fire needling or warm needling treatment alone, ii) fire needling and bloodletting combination treatment, iii) combination of fire needling, bloodletting, and herbal medicine, iv) warm needling (concurrently). Heat stimuli in acupuncture alone or in combination treatment were more effective in terms of the total efficacy rates, uric acid levels, and pain scores than WM alone. Results: In all the evaluation tools, the treatment effects in the fire needling alone or warm needling alone treatment group and the fire needling and bloodletting combination intervention group were significantly better than those in the WM control group. The warm needling and WM combination intervention groups also experienced significantly better treatment effects in terms of total efficacy rates and uric acid levels. Only the pain scores in the fire needling, bloodletting, and herbal medicine combination groups demonstrated significant improvement. Only four studies mentioned adverse reactions: one reported loss of appetite; three studies reported none. According to the Cochrane RoB tool, most studies showed either high or uncertain RoB. Conclusion: Heat stimuli during acupuncture could be effective for acute gout. However, as the included studies were regionally biased, more high-quality studies are needed to confirm the level of evidence.

고층건축물 수직공간의 화재 시 압력차 분석을 위한 실험적 연구 (An Experimental Study on the Analyze the Pressure Difference in case of Fire in Vertical Space of High-Rise Buildings)

  • 허예림;김혜원;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2020
  • As buildings in South Korea become more skyscrapers, the risk of fire is also emerging. Thus, regulations, regulations, and guidelines are being improved to prevent the spread of smoke in the event of a fire in high-rise buildings, but research on smoke flow and pressure distribution in vertical spaces is insufficient. Therefore, in this study, the temperature of each floor in the vertical space according to the size of the fire is measured through the miniature model experiment, and the pressure difference is calculated to establish the basic data for the improvement of the performance of domestic air supply facilities in the future. Thus, a scale model of one-sixth the size of the actual building was produced to measure the temperature, and the pressure difference was derived by substituting the value for the expression. The pressure difference varies depending on the size of the cause of the fire, and it is believed that the differential pressure and conditions of the building should be taken into account before calculating the supply volume for the analysis of the pressure difference according to the size of the cause of the fire in the event of fire.

  • PDF

염화수소 누출에 따른 소방계획서 개선방안 (Improvement of Fire Safety Management Plan in Response to Hydrogen Chloride Leak)

  • 백부현;공하성
    • 대한안전경영과학회지
    • /
    • 제26권3호
    • /
    • pp.39-49
    • /
    • 2024
  • This study aims to propose an improvement of fire safety management plans for buildings, such as apartment complexes and schools, within a 10 km radius of industrial complexes. It utilizes an off-site consequence analysis program to reflect the toxic impact on national industrial complexes and surrounding areas. The ALOHA program was utilized to analyze the impact of toxicity due to a hydrogen chloride leak, a hazardous material. The results showed that the area with AEGL-2 and above ranged from 3.1 km to 10 km, the AEGL-3 area ranged from 1.9 km to 7.3 km. The ASET was measured to be between 3 and 24 minutes. Due to the impact of toxicity, it is necessary to prepare fire safety management plans for buildings, such as apartment complexes and schools that are within a 10 km radius from industrial complexes. These safety plans incorporate the hydrogen chloride risk assessment results, ASET, weather conditions, and coordination with the local community.

위험성 평가 프로그램 PML-Chem 개발 (The Development of Risk Assessment Program PML-Chem)

  • 김윤화;김형석;신동일;김인원;고재욱
    • 한국안전학회지
    • /
    • 제14권2호
    • /
    • pp.97-102
    • /
    • 1999
  • This study is to develope the quantitative risk assessment program for consequence analysis of fire and explosion (PML-Chem), which is applicable to the chemical plants. The advantages of PML-Chem is easy to use and acquire results. Especially, PML-Chem was embedded real weather condition database for major chemical plants in ${\bigcirc}{\bigcirc}$ complex in country. Also, reliability of PML-Chem was verified through comparing PML-Chem with PHAST-Professional which is already commercial.

  • PDF

발포 프라스틱의 착화특성 및 연소가스 분석 (Ignition Characteristics and Combustion Gas Analysis of the Plastics Foam)

  • 이근원;김관응
    • 한국안전학회지
    • /
    • 제16권1호
    • /
    • pp.48-52
    • /
    • 2001
  • This study was undertaken to investigate fire risk characteristics of the plastics foam that is used an insulating materials in workplaces. The ignition characteristics and combustion gas of the plastics foam were carried out using the ISO self-Ignition tester, the Cone Calorimeter, and NES combustion analyzer. The experimental materials used were commercial samples and their composition is not disclosed by the manufacturer. As the experimental results, the self-ignition temperature of the plastics foam ranges from $410^{\circ}C$ to $510^{\circ}C$, and the flash-ignition temperature of plastics foam ranges from $370^{\circ}C$ to $450^{\circ}C$. The difference of ignition temperature on density with plastics foam type was smaller since the amount of combustible gas to ignite is not caused enough. The time to ignition of the polyethylene foam in samples of the plastics foam was shorter, and its of polyethylene foam was longer. The concentration of carbon dioxide of the polyethylene foam shows higher in samples of the plastics foam. It is found that the concentration values of carbon monoxide of the plastics foam show very fatality on people during exposure of 30 minutes in fire.

  • PDF

Safety of Train Passengers in a Tunnel

  • Kim, Dong-Jin;Moon, Dae-Seop;Moon, Seong-Am;Hwang, Young-Ha
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.16-21
    • /
    • 2007
  • Along with the opening of the high speed railroad in 2004, the number of long tunnels constructed is increasing and will be continued. In this respect, the fro inside the tunnels is a main cause of drastic damages to both facilities and lives of passengers on board, especially more severe consequences are expected if the fire occurs on a train in urban area. Even though, the threat to human lives due to the increasing number of tong tunnels and increasing train operation times inside such tunnels is getting bigger, the studies to measure safety of the tunnel and to enhance the safety of passengers have not been carried out enough in Korea. Therefore, in this paper, we will use the probabilistic method to predict the average number of deaths of passengers in case of fire on a train iii tunnel, and show the potential risk to passengers which can be a guide for safer design of tunnels to be constructed.

숲가꾸기 산물의 적재형태에 따른 산불위험성 비교 분석 (Comparative Analysis of Forest Fire Danger Rating on Accumulation Types of the Leaving of Thinning Slash)

  • 이시영;이명욱;이해평
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.45-53
    • /
    • 2008
  • 본 논문은 숲가꾸기 산물인 간벌목이 산불에 미치는 영향에 대하여 연구하였다. 즉, 간벌목이 산불에 미치는 영향을 조사하고자 강원도 양양군과 인제군, 경기도 가평군의 숲가꾸기 실행지와 미실행 지역을 선정하였다. 이 조사대상지에 대하여 수종, 입지특성, 간벌강도, 숲가꾸기 종류, 간벌재의 적재행태 및 산불위험도에 대한 조사를 수행하였다. 조사대상지인 양양군 5개소, 가평군 4개소, 인제군 5개소 총 14개 조사구에 대하여 숲가꾸기 실행지 9개소, 미실행지 5개소에 대한 현장조사를 실시하였다. 숲가꾸기 미실행지 5개소는 숲가꾸기 실행지와 인접한 조사지역을 선정하였고, 숲가꾸기 실행지와의 산불위험도에 대해 비교 분석을 수행하였다. 본 연구의 조사결과 숲가꾸기 실행지의 산물인 간벌목의 적재높이는 1 m 미만으로 적재되어 있어 산불연소시 수관부로 전파될 위험성은 거의 없는 것으로 판단되었다. 그러나 적재된 간벌목과 임목간의 거리가 거의 붙어 있어 적재된 간벌목에 산불이 붙을 경우 임목 줄기부(수간)에 직접영향을 줄 것으로 판단된다. 그리고 적재된 간벌목이 많이 쌓여 있을 경우 이로 인하여 재발화의 가능성이 있을 것으로 판단되었다.