• Title/Summary/Keyword: Fire Regulations

Search Result 255, Processing Time 0.127 seconds

선박 화재안전과 SOLAS 협약

  • Ryu, Eun-Yeol
    • Fire Protection Technology
    • /
    • s.17
    • /
    • pp.24-32
    • /
    • 1994
  • This article introduces the transition of SOLAS (The International Convention for the Safety of Life Sea) safety regulations for fire protection, fire detection and fire extinction in ships. And also the regulations and the related IMO fire test rules applied to products such as fire sep-arate walls and non-combustible materials for interior to prevent fire spread on the ship fire are summarized.

  • PDF

A Study on Data Research for Fire Regulations and Fire Retardant in Interior Architecture (실내건축관련 소방(消防)규정과 방염(防炎)에 관한 연구)

  • Cho, Sung-O;Kim, Yong-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.95-102
    • /
    • 2010
  • Recently, a grow in size and features of Interior construction work over the complex and The Fire-related regulations have been strengthened for the prevention of fire damage. This study is purpose to propose interior design, construction and supervision for the efficient and reasonable way throughout the fire-related laws are investigated in interior architecture. First, the interior of the building work will be based on actual use Fire-related Laws and Regulations have be investigated. Second, based on analysis of material and facilities by Application can be used in production by the data were applied to the present. Third, the international Fire and Flame Retardant Standards for investigating and reviewing the relevant laws, differences and characteristics of each country were analyzed. Fourth, the various fire-related issues of regulation and the application of relevant provisions in the field works, the law's standards, and improvements were identified by analysis. Fire-Related Laws and Building codes that Safety Administration of the Fire Services are divided into design, it comes to approval from the municipal authorities with concerns about the fire that will fit on the Fire Department's administrative procedures and operations is necessary to integrate operations. In conclusion, Fire-related business are divided into Minister of Land, Transport and Maritime Affairs and Ministry of Public Administration and Security. So, Both institutions is need to be the cooperative work. It is necessary to the field supervision. Because, Flame-resistant performance standards in the field works applied are too complex. Last, Establishment of fire-related regulations will enact by private organizations and the experts to participate.

A Study on the Safety Measures of Camping Ground Fire (야영장 화재 안전대책에 관한 연구)

  • Choi, Ji-Hun;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • The leisure life pattern of people is changing to a familial and enthusiastic way that eventually develops the camping culture. Thus, the number of campers and the size of camping market have been dramatically increased due to significant expansion of camping people. However, many camp grounds and facilities are operating without a proper registration by government rules and regulations. In addition, many of electronic and gas equipment and tools are not used in a safe way and in a safety regulatory boundary. Therefore, campers at the camping ground is situated in a fire and safety hazard. In addition, there is limitation in rules and regulations associated with camping ground safety and fire. This study analyzed the fire and hazard guidelines and rules regulations of developed countries of campground and compared them to the current situation in South Korea. Therefore, this study is to develop a safety and fire hazard guidelines and rules and regulations related to camp ground operation, gas and electronic equipment operation and management. The study will eventually reduce the future fire and safety incidents in a campground in South Korea.

Deregulation of the Fire Prevention Legislation; and Its Impact on Fire Occurrence - Case of the United Kingdom - (′화재예방법규′의 규제완화가 화재발생에 미치는 영향 -영국 사례분석 -)

  • 이재열
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.13-19
    • /
    • 2001
  • The OECD defines regulatory reform as both better regulation and deregulation, and emphasizes that governments must continue to regulate in areas such as environmental quality and safety. In contrast, Korean regulatory reform in fire services in the 1990s shows quite a strange trend, having been carried out only to the direction of softening and abolishing regulations. In the UK, fire prevention legislation has been strengthened since the enactment of the Fire Precautions Act 1971, and the Building Regulations 1991, which apply to all new buildings including a private house, require that there should be at least one smoke alarm on each floor. This research shows that the tightening of fire prevention legislation in the UK has promoted fire safety, which is very instructive for Korean fire services. In order for Korean fire services to protect citizens'lives and property from fires, one of basic directions of regulatory reform, to improve the quality of regulations relating to safety, health and the environment, should be observed strictly. Moreover, the flexibility of the basic direction of regulatory reform should be ensured so that the regulations concerning safety could be even increased under the overall reform strategy of reducing all regulations.

  • PDF

A Study on Improvement of Domestic Airport Service for Rescue and Fire Fighting (국내 공항 구조 및 소방 업무 개선방안 연구)

  • Han, Jae-Hyun;Chung, Ki-Yeon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.4
    • /
    • pp.69-74
    • /
    • 2008
  • Aircraft fires due to accident at an airport may be under a special situation. An outstanding characteristic of aircraft fires is their tendency to reach lethal intensity within a very short time. In domestic aviation act, there are regulations related to services coping with the aircraft accidents within an airport. To cope aircraft fires, it is necessary to define clearly the regulations and standards about the services and related activities of rescue and fire fighting, and to keep the regulations and standards. The study has been performed on the basis of International Civil Aviation Organization (ICAO) Airport Services Manual of rescue and fire fighting. The objective of study is to suggest improvement methods for standards applicable to actual service practices of rescue and fire fighting by analyzing through the comparison of domestic and international regulations and standards.

  • PDF

A Study on the Needs to Improve the Regulations and the Design Features of Fire Protection for UAE Nuclear Power Plants (UAE원전 화재방호계통 설계특성과 화재방호규제 개선 필요성 연구)

  • Ma, Jin-Soo;Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.54-61
    • /
    • 2011
  • The study is to analysis of fire protection regulations for the nuclear power plants (NPP) in the United States, Japan, the UAE (United Arab Emirates), and Korea with the intention of exporting NPP to the UAE. Fire protection regulations for NPP for these countries permit the fire protection design and facilities in accordance with the evaluation of the potential fire hazards. However, in Korea, the NPP is a part of power generation facilities in Korea fire protection law, and the atomic energy act classifies them as the reactor and related nuclear facilities. The fire protection law and atomic energy act are different to the criteria for the fire protection of NPP. To maintain the leading position as a nuclear exporting country, the performance-based fire hazard analysis should be reasonably incorporated in the design of the fire protection system. It was suggested that the integrated requirements of the fire protection for NPP should be incorporated to the construction article for the fire protection facilities specified in paragraph 2 of Act II, being classified into the special objects to be protected against fire, which requires a performance-based design in order to incorporate the specific requirements for NPP.

A Comparative Analysis of Domestic and Foreign Standards to Improve the Performance of Zone Smoke Control System (거실 제연설비 성능 개선을 위한 국내·외 기준 비교 분석에 관한 연구)

  • Huh, Ye-Rim;Kim, Yoon-Seong;Kim, Hye-won;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.83-84
    • /
    • 2022
  • In Korea, smoke control measures through NFSC 501 are proposed to reduce human casualties caused by smoke in the event of a fire. However, as a result of investigating and analyzing domestic and foreign standards, it was found that domestic regulations do not set fire source, but simply set smoke emissions by floor area or height of smoke boundary. Foreign regulations set fire source. Therefore, it is judged that it is necessary to review whether the current domestic regulations can be applied in the event of an actual building fire. So, this paper aims to identify the differences in domestic and foreign standards through investigation and analysis of related standards for fire zone smoke control system in each country and use them as basic data to improve the performance of zone smoke control system.

  • PDF

Study of the Effective Management and Care System on in-Use Fire Fighteris Turnout Gear (소방복 유지관리시스템의 효율화 방안)

  • Son, Bong-Sae;Choi, Kye-Youn
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.72-77
    • /
    • 2011
  • This study aims to provide fundamental information required to establish an efficient maintenance and management system for fire fighting clothing which takes into account the domestic fire protection environment and situation. There aren't any detailed regulations and appropriate pre-inspection systems which would be required for proper maintenance of fire fighting clothing, as well as any test methods to determine the life spans of fire fighting clothing properly. Thus, this study tries to analyze the problems in use of fire fighting clothing and its maintenance situation and summarize overseas maintenance situation for fire fighting clothing. As a result, it is found that domestic fire fighting clothing is washed, repaired, and stored without any systematic management regulations. It is also found that the life spans of fire fighting clothing are determined, based on part of overseas management regulations on fire fighting clothing. Therefore, it is imperative to set up efficient management regulations and test methods for fire fighting clothing which would be required for efficient use of the fire fighting budgets and the life safety of fire fighters.

An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.4
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.

A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses (다중이용업소 실내마감재료 사용기준에 관한 연구)

  • Kim, Yong-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.