Fire Simulation for Vent Flow and Temperature in Engine Room of Small Ship: Effects of Ceiling Duct Location and Side Vent Size (소형선박 기관실의 개구부 유동 및 온도에 대한 화재시뮬레이션: 천장 통풍통 위치 및 측면 개구부 크기 영향)

  • Jeong, Lee-Gyu;Lee, Chi Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.454-465
    • /
    • 2020
  • Fire simulations were performed using the Fire Dynamics Simulator (FDS) software to examine the vent flow and temperature in the engine room of a small ship. A diesel fire with a heat release rate of 10 kW was targeted, and the effects of the ceiling duct location, side vent existence and nonexistence, and side vent size were investigated. The existence or nonexistence of the side vent and its size considerably affected the smoke behavior, mass flow rate through the vent, and temperature. When the side vent was not installed or was small, the smoke layer reached the floor in the engine room. In addition, as the side vent size increased, the mass flow rate through the vent increased with decreasing temperature value. However, the effects of the ceiling duct location on the smoke behavior, mass flow rate through the vent, and temperature seemed to be relatively minor compared to those of the side vent size. Therefore, to improve the fire safety of the engine room in a small ship, the side vent size is considered to be a more important design factor than the ceiling duct location.

The Real Fire Test in Bedroom for the Performance Based Fire Design (성능기반 화재안전설계를 위한 침실 공간에서의 실화재 실험)

  • Kim, Hyung-Jun;Kwon, In-Kyu;Kweon, Oh-Sang;Kim, Heung-Youl;Chae, Seung-Un
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.32-37
    • /
    • 2013
  • For The performance based fire design of the buildings, the fire characteristic such as proceeding and scale of the fire should be figured out but, there is lack of relevant information because of different conditions and difficulties of mock-up test like type of division space, ventilation condition, etc, in buildings. Therefore, in the study, a heal release rate etc, the engineering characteristic data value on the fire is proposed by mock-up fire test for division space in buildings. The mock-up fire test is carried out in a bedroom with 2.4 (L) ${\times}$ 3.6 (W) ${\times}$ 2.4 (H) m model. Initial ignition was started from trash box and the test was carried out for 30 min. As a result of the fire test, flame was broken to outside within 7 min and 50 s after starting the test and the maximum heat release rate was measured as 3,810.6 kW at 9 min and 34 s.

Examination on Fire Extinguishing Performance of Full Cone and Hollow Cone Twin-fluid Atomizers: Effects of Supply Gas and Water Mist (중실원추형 및 중공원추형 2유체 미립화기의 화재 소화 성능 검토: 공급 기체와 미분무 영향)

  • Kim, Dong Hwan;Lee, Chi Young
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.28-36
    • /
    • 2019
  • In the present study, the effects of supply gas and water mist on the heptane pool fire extinguishing performance were investigated using the full cone and hollow cone twin-fluid atomizers. Air or nitrogen of 30 lpm (Liter per minute; L/min) was used as the supply gas, and the experiments were conducted under the water flow rate conditions of 0 lpm (i.e., discharge of air or nitrogen only) and 0.085 lpm (i.e., discharge of water mist with supply gas). Experimental results confirmed that the use of water mist discharge with the supply gas and full cone spray pattern reduced the fire extinguishing time as compared to that of only supply gas discharge and hollow cone spray pattern. In addition, for the discharge of water mist using the full cone twin-fluid atomizer, water mist significantly affected fire extinguishing performance, whereas the effect of the supply gas was less pronounced. On the other hand, for the discharge of water mist using the hollow cone twin-fluid atomizer, the fire extinguishing time was remarkably reduced by the supply of nitrogen, as compared with that of air, indicating that the supply gas as well as water mist can significantly affect fire extinguishing performance.

A Study on the Heat Hazard Assessment of Building Wood (건축용 목재의 열 유해성 평가에 대한 연구)

  • Woo, Tae-Young;Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.6-14
    • /
    • 2018
  • This study was carried out with respect to the heat release rate (HRR) properties of building wood. Heat release characteristics were measured using a cone calorimeter (ISO 5660-1) with four kinds of wood. The time to ignition measured after the combustion in $25kW/m^2$ external heat flux was 35 to 55 s. Time to ignition of both lauan and red pine was marked with the most delayed value in each of 54 s, 55 s. The maximum heat release rate ($HRR_{peak}$) was $156.87{\sim}235.1kW/m^2$, and the risk of early fire was highest in spruce. Total heat release of red pine was obtained in the highest value with $114.2MJ/m^2$. The mean effective heat of combustion of Japanese cedar was 19.1 MJ/kg and the highest among the samples. Fire risk of wood by FPI was orderly increased from lauan ($0.2468s{\cdot}m^2/kW$), red pine ($0.2339s{\cdot}m^2/kW$), spruce ($0.2308s{\cdot}m^2/kW$) to Japanese cedar ($0.2231s{\cdot}m^2/kW$). Fire risk of wood by FGI get increased from lauan ($0.5088kW/m^2{\cdot}s$), red pine ($0.5111kW/m^2{\cdot}s$), Japanese cedar ($2.8522kW/m^2{\cdot}s$) to spruce ($3.0662kW/m^2{\cdot}s$). Therefore, the risk of fire on the heat release characteristics of woods were found that spruce and Japanese cedar showed the high value compared with the other specimens.

APPLICATIONS OF A MODEL TO COMPARE AFLAME SPREAD AND BEAT RELEASE PROPERTIES OF INFERIOR FINISH MATERIALS IN A COMPARTMENT

  • Kim, Woon-Hyung;James G. Quintiere
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.193-200
    • /
    • 1997
  • Flame spread and heat release properties and incident heat flux of interior materials subject to an igniter heat flux in a compartment are investigated and compared by using computer model. A comer fire ignition source is maintained for 10 minutes at 100 kw and subsequently increased to 300kw. In executing the model, base-line material properties are selected and one is changed for each run. Also 4 different igniter heat flux conditions and examined. Results are compared for the 12 different materials tested by the ISO Room Comer Test (9705). The time for total energy release rate to reach 1MW is examined. The parameters considered include flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The model can show the importance of each property in causing fire growth on interior Hnish materials in a compartment. The effect of ignitor heat flux and material property effects were demonstrated by using dimensionless parameters a, b and Tb. Results show that for b greater than about zero, flashover time in the ISO Room-Corner test is principally proportional to ignition time and nothing more.

  • PDF

A Study on Fire Risk of Apartment House with Pilotis Structure - Focused on the Fire case of Uijeongbu-si Urban Livig Homes - (필로티 구조의 공동주택 화재 위험성 연구 - 의정부 대봉그린 도시형아파트 화재 사례를 중심으로 -)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.48-54
    • /
    • 2016
  • Pilotis are support columns that lift a building above the ground. Thus, they can elevate the lowest floor to the secondfloor level and, in Korea, are used to leav a parking area below multifamily housing. However, if there is a fire in the piloti area, the cars and main entrance door are wrapped in flames. Due to the inflammability of the materials, the combustion of the cars and insulation at the ceiling of the pilotis, having a high heat release rate, can quickly destroy the front entrance of the building and spread heat, flames and a poisonous gas to the stairs and elevator pit. Therefore, the fire can quickly spread to the whole building, putting the lives of the residents in danger. This study was an in-depth accidental case study of the "Uijeongbu Fire Accident" that killed 5 residents and injured 139 others. The study identified the relationships between the fire at the piloti structure of multifamily housing and the vulnerability of this structure and its inherent weaknesses.

The Selter Selection Plan due to Formaldehyde Leakage (포름알데히드 누출에 따른 대피장소 선정 방안)

  • SeungJu Oh;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.117-129
    • /
    • 2023
  • This study tested the effect on the toxicity of formaldehyde to select a shelter site due to formaldehyde leakage. As a result of the experiment, the range of ERPG-2 and 3 is between 2.2km and 9.6km, ASET is 6 minutes at 1km, 15 minutes at 3km, 22 minutes at 5km, and the lethality rate is 99.9% at 1km and 9% at 3km. In areas where refuge time is less than 15 minutes or the lethality rate is more than 2%, a shelter is installed. This is because if there are only a few evacuees, the evacuation time may take longer than the pre-movement time of 15 minutes or less specified in PD 7974-6:2004, and the lethality rate with the lowest number of deaths was calculated to be 2%. The shelter must be equipped with a hepa-filter, positive pressure equipment, air purifier, air respirator, goggles, chemical protective clothing type 4 and sufficient parking space must be secured to ensure the safety of evacuees.

The Reserch on Actual Condition of Crime of Arson Which Occurs in Korea and Its Countermeasures (방화범죄의 실태와 그 대책 - 관심도와 동기의 다양화에 대한 대응 -)

  • Choi, Jong-Tae
    • Korean Security Journal
    • /
    • no.1
    • /
    • pp.371-408
    • /
    • 1997
  • This article is the reserch on actual condition of crime of arson which occurs in Korea and its countermeasures. The the presented problem in this article are that (1) we have generally very low rate concern about the crime of arson contrary to realistic problems of rapid increase of crime of arson (2) as such criminal motives became so diverse as to the economic or criminal purpose unlike characteristic and mental deficiency of old days, and to countermeasure these problems effectively it presentation the necessity of systemantic research. Based on analysis of reality of arson, the tendency of this arson in Korea in the ratio of increase is said to be higher than those in violence crime or general fire rate. and further its rate is far more greater than those of the U.S.A. and Japan. Arson is considered to be a method of using fire as crime and in case of presently residence to be the abject, it is a public offense crime which aqccompany fatality in human life. This is the well It now fact to all of us. And further in order to presentation to the crime of arson, strictness of criminal law (criminal law No, 164 and 169, and fire protection law No. 110 and 111) and classification of arsonist as felony are institutionary reinforced to punish with certainty of possibility, Therefore, as tendency of arson has been increased compared to other nations, it is necessary to supplement strategical policy to bring out overall concerns of the seriousness of risk and damage of arson, which have been resulted from the lack of understanding. In characteristics analysis of crime of arson, (1) It is now reveald that, in the past such crime rate appeared far more within the boundary of town or city areas in the past, presently increased rate of arsons in rural areas are far more than in the town or small city areas, thereby showing characteristics of crime of arson extending nation wide. (2) general timetable of arson shows that night more than day time rate, and reveald that is trait behavior in secrecy.(3) arsonists are usually arrested at site or by victim or report of third person(82,9%).Investigation activities or self surrenders rate only 11.2%. The time span of arrest is normally the same day of arson and at times it takes more than one year to arrest. This reveals its necessity to prepare for long period of time for arrest, (4) age rate of arson is in their thirties mostly as compared to homicide, robbery and adultery, and considerable numbers of arsons are in old age of over fifties. It reveals age rate is increased (5) Over half of the arsonists are below the junior high school (6) the rate of convicts by thier records is based on first offenders primarily and secondly more than 4 time convicts. This apparently shows necessity of effective correctional education policy for their social assimilation together with re-investigation of human education at the primary and secondary education system in thier life. The examples of motivation for arosnits, such as personal animosity, fury, monetary swindle, luscious purpose and other aims of destroying of proof, and other social resistance, violence including ways of threatening, beside the motives of individual defects, are diverse and arsonic suicide and specifically suicidal accompany together keenly manifested. When we take this fact with the criminal theory, it really reveals arsons of crime are increasing and its casualities are serious and a point as a way of suicide is the anomie theory of Durkheim and comensurate with the theory of that of Merton, Specifically in the arson of industrial complex, it is revealed that one with revolutionary motive or revolting motive would do the arsonic act. For the policy of prevention of arsons, professional research work in organizational cooperation for preventive activities is conducted in municipal or city wise functions in the name of Parson Taskforces and beside a variety of research institutes in federal government have been operating effectively to countermeasure in many fields of research. Franch and Sweden beside the U.S. set up a overall operation of fire prevention research funtions and have obtained very successful result. Japan also put their research likewise for countermeasure. In this research as a way of preventive fire policy, first, it is necessary to accomodate the legal preventitive activities for fire prevention in judicial side and as an administrative side, (1) precise statistic management of crime of arson (2) establishment of professional research functions or a corporate (3) improvement of system for cooperative structural team for investigation of fires and menpower organization of professional members. Secondly, social mentality in individual prospect, recognition of fires by arson and youth education of such effect, educational program for development and practical promotion. Thirdly, in view of environmental side, the ways of actual performance by programming with the establishment of cooperative advancement in local social function elements with administrative office, habitants, school facilities and newspapers measures (2) establishment of personal protection where weak menpowers are displayed in special fire prevention measures. These measures are presented for prevention of crime of arson. The control of crime and prevention shall be prepared as a means of self defence by the principle of self responsibility Specifically arsonists usually aims at the comparatively weak control of fire prevention is prevalent and it is therefore necessary to prepare individual facilities with their spontaneous management of fire prevention instead of public municipal funtures of local geverment. As Clifford L. Karchmer asserted instead of concerns about who would commit arson, what portion of area would be the target of the arson. It is effective to minister spontaveously the fire prevention measure in his facility with the consideration of characteristics of arson. On the other hand, it is necessary for the concerned personnel of local goverment and groups to distribute to the local society in timely manner for new information about the fire prevention, thus contribute to effective result of fire prevention result. In consideration of these factors, it is inevitable to never let coincide with the phemonemon of arsons in similar or mimic features as recognized that these could prevail just an epedemic as a strong imitational attitude. In processing of policy to encounter these problems, it is necessary to place priority of city policy to enhancement of overall concerns toward the definitive essense of crime of arson.

  • PDF

Fire Risk of Wood Treated With Boron Compounds by Combustion Test (연소시험에 의한 붕소 화합물 처리 목재의 화재위험성)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.19-26
    • /
    • 2018
  • Experiments on the combustion characteristics of untreated wood specimens and also treated ones with boric acid and ammonium pentaborate were carried out using a cone calorimeter according to ISO 5660-1 standard. As a result, comparing to untreated specimen, the fire performance index (FPI) of the specimens treated with boron compounds increased by 1.2 to 2.1 times and the fire growth index (FGI) increased by 1.6 to 8.4%. Also, total smoke release rate (TSR) was 9.0 to 28.3% lower than that of the untreated specimen. It is understood that the test specimens treated with the boron compound produces a carbonized layer with a flame retarding effect. The highest CO concentration, 0.01112%, for the untreated specimen was observed at 418 s, but the specimens treated with boron compound decreased 13.2 to 37.5% compared to untreated specimen. Therefore, wood treated with boron compounds is expected to have lower fire hazards and risks.

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.