• Title/Summary/Keyword: Fire Modeling

Search Result 336, Processing Time 0.022 seconds

A Numerical Study on Temperature Prediction Bias using FDS in Simulated Thermal Environments of Fire (모사된 화재의 열적환경에서 FDS를 이용한 온도 예측오차에 관한 수치해석 연구)

  • Han, Ho-Sik;Kim, Bong-Jun;Hwang, Cheol-Hong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.14-20
    • /
    • 2017
  • A numerical study was conducted to identify the predictive performance for the bare-bead thermocouple (TC) using FDS (Fire Dynamics Simulator) in simulated thermal environments of fire. A relative prediction bias of TC temperature calculated from reverse-radiation correction by FDS was evaluated with the comparison of previous experimental data. As a result, it was identified that the TC temperatures predicted by FDS were lower than the temperatures measured by bare-bead TC for the ranges of heat flux and gas temperature considered. The relative prediction bias of TC temperature by FDS was gradually increased with the increase in radiative heat flux and also significantly increased with the decrease in the gas temperature. Quantitatively, at the gas temperature of $20^{\circ}C$, the TC temperature predicted by FDS had the relative bias of approximately -20% with the radiative heat flux of $20kW/m^2$ corresponding to thermal radiation level of the flashover. It is predicted from the present study that more accurate validation of fire modeling will be possible with the quantitative prediction bias occurred in the process of reverse-radiation correction of temperature predicted by FDS.

Optimum Fire Extinguishing Modeling using Impact Factor Analysis on Water Mist System of Pool Fire (영향인자 분석을 통한 고임화재의 미분무수 최적소화 모델링)

  • Hwang, Won-Jun;Kim, Hwang-Jin;Lee, Sung-Eun;Kim, Sung-Won;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.84-89
    • /
    • 2009
  • In this study, the fire extinguishing experiment was performed using a water mist nozzle with variation of factors which affect on the extinguishing time. The variables were distance from nozzle center to fire location, droplet size, height of nozzle and opening or not. With the experimental data, interaction and sensitivity between factors were analysed with Mini tab and deduce a optimum model of fire extinguishing of water mist system. Based on the experiment and modeling of fire extinguishing with water mist system, the most important factor on extinguishing time is the distance from the center of nozzle to fire and the opening effect was small compare with other factors.

Consideration about the Fire Lane Plan and the Conformability - A Case Study on Daegu Metropolitan City Buk-gu - (소방차전용출동경로의 계획기법 및 적합성 검토에 관한 연구 - 대구광역시 북구를 대상으로 -)

  • Jeong, Gun-Sik;Kim, Han -Su
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.83-90
    • /
    • 2010
  • The purpose of this study is to establish the standard of fire lane design to improve the performance of disaster prevention in local area. To accomplish it, we have focused on three research methods as below: first, we have expected disaster occurrence based on emergency tendency in local area; second, we have verified fire lane routes design through fire lane modeling and network analysis; third, we have quantitatively examined a possibility of danger of fire lanes through current road network modeling and analysis. The result of this study could be helpful to effective fire lane designs and quantitative analyses.

Modeling and Analysis for Efficient Joint Combat Fire Operation of Army Artillery and Army Aviation (효율적인 육군항공과 포병자산의 통합화력 운용방안 판단을 위한 모델링 방법론 및 분석)

  • Lim, Jong-Won;Kwon, Hyog-Lae;Lee, Tae-Eog
    • Journal of the Korea Society for Simulation
    • /
    • v.23 no.2
    • /
    • pp.47-55
    • /
    • 2014
  • Most combat simulation models, including Korean Army's combat models for simulation analysis, have too much limitations to be used for analysis of complex combats like joint combat fires. We analyze requirements for modeling and simulation of Fire-Eagle, which is a joint combat fire model of ground combat fires and army aviation. We then propose a simulation model for Fire Eagle and derive operational strategies for improving the joint combat fire. To do these, we analyze effectiveness of specific operational plans and scenarios by using the simulation model. We demonstrate ways of developing efficient and effective operational plans from the simulation experimental results.

A Development of Fire Evacuation Simulation System Based 3D Modeling (3차원 공간 기반의 화재피난 시뮬레이션 시스템 개발)

  • Hwang, Yeon-Jung;Koo, Won-Yong;Hwang, Yen-Kyung;Youn, Ho-Ju
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.156-167
    • /
    • 2011
  • The number of buildings is growing at a rapid pace in Korea. It is driven by significant economic improvements, the rapid population growth and urban centralization. Such being this case, some city are underway to building enlargement, Manhattanization. To Solve these problem and ensure the safety of live, fire Evacuation Simulation system is used for safe check of buildings. Forecasting an egress behavior in building fire is so important in order to construct a safe and reliable environment. But, currently most of the fire evacuation simulation system used in practice are foreign software that is not reflect korean conditions. Thus, This study focus on objectives that develop a fire evacuation system considering Korean Characteristics and create 3D space-based topology. so the system calculate evacuation path. This system developed as a result of research can be used by architectural designer in practice due to it is based 3D spatial information modeling.

A Study for Thermal Mechanism of Residential Combustibles with Numerical Modeling (주거공간 단위가연물의 열역학적 수치해석 모델링에 관한 연구)

  • Ahn, Chan-Sol;Kim, Jung-Yup;You, Yong-Ho;Kweon, Oh-Sang;Joo, Sang-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.58-63
    • /
    • 2011
  • This study is intended to present a computational thermal model for the combustibles in a residential building. As the Performance Based Design is more popular, fire-intensity and fire-load have turned out to be very important factors for building design and can be predicted through some computational work. To predict and estimate the thermal properties of the residential combustible fire, we made some numerical models of combustibles in a residential building. In a bid to validate the estimate values, computational analysis results from numerical models were compared with real fire tests. For computational analysis, the Fire Dynamics Simulator was used with Large Eddy Simulation model for turbulence. Consequently, each heat release rate and total heat release curves were successfully estimated.

Comparison of Egress Modeling and Experiments for Flow Rate in the Bottleneck (병목현상 시 유동률에 대한 피난실험 및 모델링 비교)

  • Hwang, Eun-Kyoung;Woo, Sujin;Kim, Jong-Hoon;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.35-40
    • /
    • 2014
  • Bottleneck occurs as many people crowd into narrow doorway or corridor. Delaying egress time is occurred by bottleneck effect, and it is very important phenomenon on the egress analysis for building fire. An analysis of egress time should includes flow rate for considering bottleneck. Flow rate is numbers of people who pass the narrow gate as door or start point of corridor per unit length and unit time. The flow rate resulted from egress modeling should be approached to the result of experiments. In this study, flow rates from modeling by 'Pathfinder' and experiments was compared. The difference between the result from egress modeling and the one from experiments was verified. The average value of experiments is $4.25N/m{\cdot}s$, and the maximum average value of modeling is $1.55N/m{\cdot}s$.

A Study on the Risk Assessment of the Underground Space -The Estimation of Smoke Reservoir Screen for Smoke Control in Subway Station Platform (지하공간의 위험성평가에 관한 연구 -지하철 역사내의 연기제어를 위한 제연경계벽의 효용성 평가)

  • Roh Sam-Kew;Hur Jun-Ho
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.103-109
    • /
    • 2004
  • The risk of underground space become an important issue of life safety thought the Taeku subway line Accident. It is essential to study of smoke control screen to minimize the damage of human life because of smoke passage and passenger evacuation routes are on the same vertical and dispersion movement. The Fire modeling result shows the effect of fire control screen can save the evacuation time about 2-2.5 times compare to existing the system However, The designs of fire control screen need to be complied with smoke control ventilation system to present optimum design and the position of installation.

Heat Transfer Modeling of Fiber-embedded Fire-Resistant High Strength Concrete (섬유혼입 내화 고강도 콘크리트의 열전달 모델)

  • Shin, Young-Sub;Han, Tong-Seok;Youm, Kwang-Soo;Jeon, Hyun-Kyu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.2
    • /
    • pp.133-140
    • /
    • 2011
  • High strength concrete used for large structures is vulnerable to fire due to explosive spalling when it is heated. Recently, various research is conducted to enhance the fire-resistance of the high strength concrete by reducing the explosive spalling at the elevated temperature. In this study, a heat transfer analysis model is proposed for a fiber-embedded fire-resistant high strength concrete. The material model of the fire-resistant high strength concrete is selected from the calibrated material model of a high strength concrete incorporating thermal properties of fibers and physical behavior of internal concrete at the elevated temperature. By comparing the simulated results using the calibrated model with the experimental results, the heat transfer model of the fiber-embedded fire-resistant high strength concrete is proposed.