미분무수 소화 노즐의 분무 특성 예측을 위한 CFD기법의 적용 (APPLICATION OF CFD TECHNIQUE TO PERFORMANCE PREDICTION OF SPRAY CHARACTERISTICS OF WATER-MIST FIRE SUPPRESSION NOZZLES)

  • 정희택;이창효;최병일;한용식;옥영욱
    • 한국전산유체공학회지
    • /
    • 제11권4호
    • /
    • pp.56-61
    • /
    • 2006
  • Numerical simulation has been performed to investigate the characteristics of the mist flow through the fire suppression nozzles. The commercial CFD software, FLUENT with the proper modeling was applied for analyzing both the internal and external flow of the spray nozzles. Computations were made for the full cone nozzle in the operation range of the low pressure and high flow-rate. To validate the present computational procedure, numerical results are compared with measurements in terms of K-factor, SMD, axial spray velocity and spray angles. Numerical results suggested that the present numerical model can be used as an adequate tool for a design purpose of mist-spray nozzles.

소화 노즐의 분무 특성 예측을 위한 CFD 기법의 적용 (Application of CFD Technique to Performance Prediction of Spray Characteristics of Fire Suppression Nozzles)

  • 정희택;이창효;정향남;최병일;한용식;옥영욱
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.233-239
    • /
    • 2005
  • In the present study, numerical simulation has been performed to investigate the characteristics of the mist flow through the fire suppression nozzles. The commercial CFD software, FLUENT with the proper modeling was applied in both the internal and external flow region of the spray nozzles. Applications were done to the full cone nozzle for the operation range of the low pressure and high flow-rate. Numerical validation was proved by the comparison of the experimental data. Parametric study of the key design factors was tried to improve the performance.

  • PDF

원자력발전소의 스위치기어실 화재모델링 입력모수 불확실성 분석 (Uncertainty Analysis of Fire Modeling Input Parameters for Switchgear Room of Nuclear Power Plants)

  • 강대일;박종석;한상훈
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.53-60
    • /
    • 2011
  • 본 논문에서는 원자력발전소의 스위치기어실 화재로 인한 케이블 손상시간과 케이블 온도를 평가하기 위해 화재모델링 입력모수 불확실성 분석을 수행하였다. 화재모델링은 FDS 5.5를 사용하였으며 입력모수 샘플링은 Wilks 식에 따라 93회를 수행하였다. 단순히 입력모수 평균 값을 사용한 화재모델링 분석결과는 화재모델링 불확실성 분석결과보다, 케이블 손상시간은 최대 1.6배 늦게, 케이블 온도는 최대 0.45배 낮게 평가될 수 있는 것으로 나타났다.

  • PDF

지하역사 제연경계벽의 제연 효용성에 관한 연구 (A Study on the Efficiency of Smoke Barriers in the Subway Station)

  • 김범규;김희영;이성미;박용환
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.204-208
    • /
    • 2008
  • Casualties Damage from Smoke is very serious consequence. Especially, Damage from smoke in in the Subway Station is the terrible result. Smoke from the fire in the Subway Station that evacuation route on the path and the sight of refugees caused by serious traffic problems. Accordingly, A study on Smoke barriers of smoke systems take into considerations relate to effects depending on wind velocity speed of the piston effect come into the retarding effect of smoke control in smoke barriers. As a result of modeling, According to increasing of Velocity in the platform which installed smoke barriers were been on the increase spreading quantity of smoke in the right direction of upstairs however, In contrast spreading quantity of smoke in the left direction on the upstairs were been on the decrease.

  • PDF

FDS를 이용한 원전 성능기반 화재모델링 분석 (Performance-Based Fire Modeling in the Nuclear Power Plants using FDS)

  • 조성민;이규복;구희권
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.235-238
    • /
    • 2011
  • 본 논문에서는 원자력발전소 기기냉각해수격실 내 가연성 액체에 의한 화재를 가정하여 FDS 전산코드를 이용한 화재모델링 분석을 수행하였다. 특히 열방출률, 환기효과, 복사분율 등에 대한 입력변수 변경을 통해 보다 보수적인 화재시나리오 설정을 위한 환경조건을 확인하였다. 이 결과는 추후 실제 가동 중인 원자력발전소에 대한 성능기반 화재모델링 분석에 활용할 예정이다.

  • PDF

Zone Model을 활용한 장대도로터널 화재성상 예측방법에 관한연구 (A Study on the Prediction Methods of Fire Behavior Using Zone Model in Rord Tunnel)

  • 한정철;김세종;이주희;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.163-166
    • /
    • 2011
  • 본 연구는 Zone Model을 활용하여 장대도로터널의 화재성상 예측방법의 고찰을 목적으로 1/5 Scale 모형실험 및 MLZSUZUKI 결과 분석과 CFD와 MLZ의 비교 분석을 실시하였다. Modeling한 모형터널의 해석시간이 MLZ 1분, FDS 약 6시간으로 CFD에 비하여 360배의 시간 감소와 다층으로 구분하여 구간의 온도변화 및 환기풍에 의한 열기류의 움직임 등의 상황이 해석됨으로 향후 MLZ을 활용하여 터널화재의 위험성 예측에 용이할 것으로 판단된다.

  • PDF

Elevator Pressurization in Tall Buildings

  • Klote, John H.
    • 국제초고층학회논문집
    • /
    • 제2권4호
    • /
    • pp.341-344
    • /
    • 2013
  • During a building fire, smoke can flow through elevator shafts threatening life on floors remote from the fire. Many buildings have pressurized elevators intended to prevent such smoke flow. The computer program, CONTAM, can be used to analyze the performance of pressurization smoke control systems. The design of pressurized elevators can be challenging for the following reasons: (1) often the building envelope is not capable of effectively handling the large airflow resulting from elevator pressurization, (2) open elevator doors on the ground floor tend to increase the flow from the elevator shaft at the ground floor, and (3) open exterior doors on the ground floor can cause excessive pressure differences across the elevator shaft at the ground floor. To meet these challenges, the following systems have been developed: (1) exterior vent (EV) system, (2) floor exhaust (FE) system, and ground floor lobby (GFL) system.

HOT-SMOKE TESTS IN TWO UNDERGROUND RAILWAY STATIONS WITH MOVING TRAINS

  • Allan, Hugh
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.472-476
    • /
    • 1997
  • Hot-smoke testing in Australia has progressed to the stage where there is an Australian Standard for these tests. The purpose of such tests is twofold: firstly they can validate computer modeling predictions for smoke movement, and secondly they can demonstrate that the smoke control systems and associated fire safety systems function satisfactorily. Hot-smoke tests were carried out in March 1997 at two of Sydney's underground railway stations, namely St James and Museum. The purpose of the tests was to demonstrate that the smoke control systems performed their functions as intended. Tests were carried out in the concourses and on the platforms, and trains ran during the tests so that the effect of moving trains on smoke movement could be observed. A total of five tests were carried out and video recordings were taken of each. This is the first time that hot-smoke tests have been carried out in an underground station with trains running. The paper discusses some of the interesting observations and the problems identified by the tests.

  • PDF

실행위주의 소방설계 및 화재모델링의 응용 (Application of fire modeling for performance based fire protection design)

  • 김은국
    • 대한설비공학회지:설비저널
    • /
    • 제28권4호
    • /
    • pp.290-299
    • /
    • 1999
  • 지난 수십년간 소방 분야의 연구의 결과로 말미암아, 오늘날 선진국에서는 종래의 법규에 의한 규제 일변도의 소방 설계에서 탈피하여 화재의 성상을 공학적으로 분석하여 그 결과를 설계에 적용하는 "실행위주의 소방설계(performance: based fire protection design)"를 이미 시도하고 있다. 우리나라에서도 법규 적용이 어려운 새로운 공간에 대해서 화재 시뮬레이션을 통한 방재 성능 평가를 이미 적용하고 있으나, 아직 법적인 근거가 마련되지 않고 있고, 교육 전파가 되지 않고 있어서, 대부분 관련 종사자들에게는 생소하게 여겨지고 있는 실정이다. 본 고에서는 실행위주의 소방설계를 소개하고, 화재의 공학적 분석 및 우리나라의 실정, 그리고 앞으로의 방향에 대하여 설명하고자 한다.

  • PDF

EVALUATION FOR DAMAGED DEGREE OF VEGETATION BY FOREST FIRE USING LIDARAND DIGITALAERIAL PHOTOGRAPH

  • Kwak, Doo-Ahn;Chung, Jin-Won;Lee, Woo-Kyun;Lee, Seung-Ho;Cho, Hyun-Kook;We, Gwang-Jae;Kim, Tae-Min
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.533-536
    • /
    • 2007
  • The LiDAR data structure has the potential for modeling in three dimensions because the LiDAR data can represent voxels with z value under certain defined conditions. Therefore, it is possible to classify the physical damaged degree of vegetation by forest fire as using the LiDAR data because the physical loss of canopy height and width by forest fire can be relative to an amount of points reached to the ground through the canopy of damaged forest. On the other hand, biological damage of vegetation by forest fire can be explained using the NDVI (Normalized Difference Vegetation Index) which show vegetation vitality. In this study, we graded the damaged degree of vegetation by forest fire in Yangyang-Gun of South Korea using the LiDAR data for physical grading and digital aerial photograph including Red, Green, Blue and Near Infra-Red bands for biological grading. The LiDAR data was classified into 2 classes, of which one was Serious Physical Damaged (SPD) and the other was Light Physical Damaged (LPD) area. The NDVI was also classified into 2 classes which are Serious Biological Damaged (SBD) and Light Biological Damaged (LBD) area respectively. With each 2 classes ofthe LiDAR data and NDVI, the damaged area by forest fire was graded into 4 degrees like damaged class 1,2,3 and 4 grade. As a result of this study, 1 graded area was the broadest and next was the 3 grade. With this result, we could know that the burned area by forest fire in Yangyang-Gun was damaged rather biologically because the NDVI in 1 and 3 grade appeared low value whereas the LiDAR data in 1 and 3 grade included light physical damage like the LPD.

  • PDF