• 제목/요약/키워드: Fire Line

검색결과 342건 처리시간 0.029초

119 안전센터 공간계획에 관한 기초적 연구 - 2008년 이후의 재건축 및 신축건물을 중심으로 - (A Study on the Planning of 119 Rescue Centers in Interior Design - Focus on the newly-built constructions since 2008 -)

  • 김성주;김문덕
    • 한국실내디자인학회논문집
    • /
    • 제22권1호
    • /
    • pp.350-358
    • /
    • 2013
  • Due to recent change in fire stations, this study aims to propose improved directions for planning of 119 rescue centers through its analysis of spatial organization and characteristics by functional area based in case studies of new-design centers. The Korean 119 rescue centers have changed in terms of function and roles in line with the flow of changing social environments, so it has been required to give new spatial change to these centers. It's meant in this study to classify compulsory special service spaces for the 119 rescue centers by domain and to suggest design guidelines for each type of spaces. Eight case of recue centers that were newly built in and after 2008 were selected and analyzed to serve the purpose. Finally, the results of this study were as followed: First, each of the rescue centers is divided into several domain depending on the type of work, and there are meaningful characteristics in the vertical and horizontal spatial layout of the individual spaces. Second, there are specific differences among the spaces in the spatial occupation percentage. The percentage of the space for community service is obviously lower in the 119 rescue centers in Seoul than in Incheon. Third, the domain classification criteria of this study are selected based on earlier studies, and another space for community service is newly added as a result of making a case study.

다중 RISC 프로세서를 이용한 항공전자시스템컴퓨터 병렬처리기법 연구 (A study on the parallel processing of the avionic system computer using multi RISC processors)

  • 이재억;이성수;김영택;양승열;김봉규;황상현;박덕배
    • 한국항공우주학회지
    • /
    • 제30권7호
    • /
    • pp.144-149
    • /
    • 2002
  • 본 논문은 항공전자 시스템 통제와 항법 및 사격통제, 커시브 및 라스터 그래픽 심볼 생성 둥의 기능이 통합된 항공전자시스템컴퓨터(ASC) 개발을 위한 실시간 다중 프로세서 병렬처리 기법을 제안한다. 4개의 32비트 RISC 프로세서간 논리적 계층구조는 마스터-슬레이브 다중 처리방식의 비대칭 구조를 가지며, Interaction 정도는 시분할 공통 시스템 버스와 공유 메모리 등을 활용한 밀 결합 방식을 채택하고, 효율적인 버스 중재방식을 고안하여 최적성능을 구현하였다. 일련의 비행시험을 통해 개발된 ASC를 검증하였으며, 전기적 시험과 환경 및 전자기 간섭 등 관련시험 또한 수행하였다.

공간사용자의 본능적 시선탐색활동에 나타난 주사경로 알고리즘 특성 (The feature of scanning path algorithm shown at natural visual search activities of space user)

  • 김종하;김주연
    • 감성과학
    • /
    • 제17권2호
    • /
    • pp.111-122
    • /
    • 2014
  • 본 연구는 지하철 로비공간을 대상으로 한 주시실험을 통해 공간정보의 본능적 시선탐색과정에서 나타나는 주시특성에 나타난 주사경로 알고리즘을 분석하였다. 주시기간 구간별 분석에서 주시시간이 오래 경과할수록 주사유형 횟수가 증가하고 있었는데, 오래 주시할수록 주시단절이 많이 일어난 것으로 해석이 가능하며, 주시에 따른 피로나 활발한 탐색이 자연스러운 공간탐색과정에서 일어나는 과정에서 화상범위를 벗어나는 경우가 많았던 것으로 보인다. 또한 시간구간의 변화에 따른 주사유형의 변화를 추세선으로 살펴본 결과, "집중"은 시간구간의 증가와 함께 가파른 증가, "대각 수직"은 완만한 증가를 보이는 반면, "순환 혼합 수평"은 감소 경향을 보이고 있다. 공간을 주시한 피험자의 주시데이터에는 다양한 시각정보가 포함되어 있는데, "주의집중"에 나타난 주사유형을 분석한 결과, 이상과 같은 의미 있는 결론을 도출할 수 있었다. 이러한 주사유형의 증감특성은 시간의 경과에 따른 주사경향을 파악함에 있어 기초자료가 될 수 있다.

구글 맵 API를 이용한 딥러닝 기반의 드론 자동 착륙 기법 설계 (Design of Deep Learning-Based Automatic Drone Landing Technique Using Google Maps API)

  • 이지은;문형진
    • 산업융합연구
    • /
    • 제18권1호
    • /
    • pp.79-85
    • /
    • 2020
  • 최근 원격조종과 자율조종이 가능한 무인항공기(RPAS:Remotely Piloted Aircraft System)가 택배 드론, 소방드론, 구급 드론, 농업용 드론, 예술 드론, 드론 택시 등 각 산업 분야와 공공기관에서의 관심과 활용이 높아지고 있다. 자율조종이 가능한 무인드론의 안정성 문제는 앞으로 드론 산업의 발달과 함께 진화하면서 해결해야 할 가장 큰 과제이기도 하다. 드론은 자율비행제어 시스템이 지정한 경로로 비행하고 목적지에 정확하게 자동 착륙을 수행할 수 있어야 한다. 본 연구는 드론의 센서와 GPS의 위치 정보의 오류를 보완하는 방법으로서 착륙지점 영상을 통해 드론의 도착 여부를 확인하고 정확한 위치에서의 착륙을 제어하는 기법을 제안한다. 서버에서 도착지 영상을 구글맵 API로부터 수신받아 딥러닝으로 학습하고, 드론에 NAVIO2와 라즈베리파이, 카메라를 장착하여 착륙지점의 이미지를 촬영한 다음 이미지를 서버에 전송한다. Deep Learning으로 학습된 결과와 비교하여 임계치에 맞게 드론의 위치를 조정한 후 착륙지점에 자동으로 착륙할 수 있다.

천곡동굴의 수질환경 장기 모니터링 (A Long-term Monitoring of Water Quality at Chongok Cave)

  • 전병희
    • 한국지반환경공학회 논문집
    • /
    • 제14권9호
    • /
    • pp.13-19
    • /
    • 2013
  • 천곡동굴은 동해시에 자리잡고 있는 석회암동굴로서 많은 돌리네를 가지고 있어 관광적 가치와 교육적 가치가 매우 높다. 하지만 천곡동굴은 시가지에 위치하고 있어 접근이 용이한 반면 하수의 유입 등에 의해 환경적 영향을 받을 가능성이 매우 크다. 본 연구에서는 천곡동굴의 수질환경을 장기 모니터링하여 생태계의 영향을 조사하고, 향후 장기 모니터링을 위한 인자를 선정하였다. 그 결과 천곡동굴 내 지하수의 수온은 $14^{\circ}C$, 용존 산소량은 10mg/L 이상, pH는 7-8의 범위에서 안정되게 유지되고 있어, 수생태계에 부정적 영향을 주는 수질적 요소는 없는 것으로 판단되었다. 관람객의 안전을 확보하기 위한 강우기준으로서 일강우로서 60mm/d가 적절하며 향후 장기 모니터링을 위해서 전기전도도를 주된 인자로 이용하고 pH와 탁도를 보조적으로 활용하는 것이 적절하며, 계절적 변화 등을 ORP를 이용하여 모니터링하는 것이 적절하다고 판단되었다.

학령기 아동의 사고예방 교육안 개발 및 평가 (Development and Evaluation of Injury Prevention Education Proposal for Elementary School Children)

  • 이정은;김지현;김신정
    • Child Health Nursing Research
    • /
    • 제8권4호
    • /
    • pp.365-380
    • /
    • 2002
  • This study was to develop and evaluate injury prevention education proposal which will helpful and can be utilized directly on the first line spot for elementary school children. Education proposal development and evaluation process was 1) Construction of 10-times education proposal contents proper to schooler 2) Testify validity through 3 pediatric nursing professor and 4 elementary school nurse 3) Pretest was done from March, 2002 to July on 3-6th grade 313 elementary school students 4) Through correction and revision after pretest evaluation meeting, final injury prevention education proposal was developed 5) After 10-times injury education, evaluation was carried out about the degree of help in education contents and general constitution of injury education to total subjects of educated children. Injury prevention education proposal consists of 10 times and each subjects are followings. 1st is 「introduction of injury prevention education and the importance of injury prevention」 2nd is「safety in and around home」, 3rd is 「injury prevention in school」, 4th is 「prevention of violence」, 5th is 「motor vehicle safety」, 6th is 「water safety」, 7th is 「prevention of fire and burns」, 8th is 「toy and product safety」, 9th is 「sports and recretional activities safety」and the final 10th is 「injury prevention caused by animals」. In the evaluation, the degree of help in education contents showed it helped to children averaged 1.66 and general constitution showed averaged 2.17 that children satisfied about developed injury prevention proposal. This study expected to provide systematic and concrete guidance in injury prevention education for elementary school children.

  • PDF

보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법 (Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers)

  • 정재진;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF

청주 성안동의 옛 가로망에 관한 연구 (A Study on the old Roads and Alleys lasting more than 100 years in Historic Urban Area(Seongan-dong) of Cheongju Korea)

  • 김태영
    • 한국농촌건축학회논문집
    • /
    • 제17권3호
    • /
    • pp.11-18
    • /
    • 2015
  • This study is aimed to clarify the transitional characteristics of old roads and alleys lasting more than 100 years(1915-2015) in traditional urban area(Seongan-dong) of cheongju, historic inland and castle city of Korea. Cheongju castle had been completely destroyed In 1915, and urban structures been also altered last 100 years from 2015 now. Periodically, after destruction of castle, existing roads were extended and transformed to straight line for connecting with around. Expanding urban area to all directions of castle boundary in 1930-40s, town planning were created. These projects were completed in 1960-70s, the street network was built as they are. Since the 1980s, changes had been occurred in the details such as an extension of the unexecuted roads, the opening of fire lane in a block, and etc. In change and construction of roads, urban district plan in 1939 and reorganization since 1967 were planned and established with the type, location, and width of the large, medium and small roads based on data before destruction of castle. Except the width of 25m Sajikro(large3-1) and Sangdangro(large3-8,9,10), the width of 15m Namsaro(medium2-1) and Namjuro (medium2-4) as an extension of the roads, the other roads were small roads equivalent to the existing roads, and so remain intact figure of streetscape. As such, roads of east-west and north-south cross type, roads showing the outline of Cheongju castle fortress, and alleys outside the south gate are sustained in Seongan-dong of cheongju as historic urban area, and also present roads are delicately executed to the existing urban fabric.

화재진압 중 소방관의 돌발 고위험상황 노출 경험과 개인보호구 개선요구사항 실태조사 (Requirements of Improvement on Personal Protective Equipment and Experiences Exposed to Accidently High Risk Circumstance while Firefighting: A Questionnaire Study)

  • 이효현;김시연;김도희;김도형;이주영
    • 한국생활환경학회지
    • /
    • 제24권5호
    • /
    • pp.549-561
    • /
    • 2017
  • We conducted a nationalwide questionnaire to investigate accidental experiences and injuries at flashover or flame-fire for active firefighters in the line of duty. A total of 794 firefighters participated in this survey (764 males, 27 females, and 3 respondents; $39.2{\pm}8.4yr$ in age, $173.7{\pm}5.1cm$ in height, $73.4{\pm}8.6kg$ in body mass). The results showed that high risk circumstances the most frequently experienced while firefighting in Korea was flashover followed by backdraft, rollover and flameover. At the high risk circumstances the most frequently-experienced injuries were bruise, stabs and burns. Firefighters hoped to reduce the total mass of personal protective equipment (PPE), improve the mobility of the PPE and dexterity of protective gloves, so that they could escape from the high risk circumstances as fast as possible. In particular, requirements for improvement on protective gloves were greater than those on other PPE. The present study suggested that the need for improvements on the current firefighters' PPE to cope with emergency high risk situations in terms of PPE mass reduction and mobility.

천연가스 공급설비에 대한 기기신뢰도 분석 및 위험성 평가 (A Study on the Reliability Analysis and Risk Assessment of Liquefied Natural Gas Supply Utilities)

  • 고재선;김효
    • 한국화재소방학회논문지
    • /
    • 제17권1호
    • /
    • pp.8-20
    • /
    • 2003
  • 천연가스는 서울에서 새로운 도시가스로서 지하배관망루 벨브스테이션을 통하여 공급되어 왔다. 그러나 천연가스는 편리함과는 대조적으로 운송시스템의 오류 또는 부주위한 취급으로부터 화재 및 폭발을 야기할 수 있는 매우 실제적인 잠재위험성을 가지고 있다. 따라서 이 연구의 주요 목적은 전형적인 배관망을 구성하는 공급설비의 신뢰성을 평가한 후 주요 잠재위험성의 확인 및 위험성평가를 수행하는 것이다. 본 연구에서는 Fault Tree Analysis와 Event free Analysis에 의해 서울의 임의의 지점 두 곳을 설정하여 최종적인 단계(top event)로서 밸브기지의 소규모 누출과 대규모 누출, 각 도시가스회사로의 천연가스공급중단을 설정하여 각각에 대한 발생빈도의 값을 알아보았다. 그 결과 소규모 누출시 DC, DS 밸브기지에 대하여 각각 3.29, 1.41의 값으로 나타났으며, 대규모 누출에 대하여는 1.90$\times$$10^{-2}$, 2.32$\times$$10^{-2}$, 또한 도시가스회사로의 천연가스공급중단에 대한 각각의 기지에 대한 수치는 2.33$\times$$10^{-2}$, 2.89$\times$$10^{-2}$로 나타났다. 또한 단위 지역 공급설비에 대한 전체적인 신뢰도와 기기별 신뢰도의 계산함으로서 기기와 공급망간의 상호관계성의 인식과, 전체 설비 굽에서 중요한 부분과 좀더 강조되어야 할 부분을 찾아내기 위해 Minimal Cut Set 방법을 사용한 결과, DC 밸브기지의 경우, 기기단위별로는 6, 7, 26, 27 등이 취약함을 보여주고 있으며, 또한 basic event 26, 27의 조합으로 인한 천연가스공급중단의 위험이 가장 크므로 이 부분에 대해서 하나의 라인이 병렬로 추가되어야만 좀더 안정적이고 위험부담이 적은 시스템으로 운영할 수 있다. 이러한 경우 공급중단의 고장율이 1/4로 줄어드는 효과를 가지게 된다. DS 밸브기지의 경우, basic event 4가 천연가스공급중단의 원인의 92%를 차지하고 있다. 그러므로 이 부분의 portion을 낮춰준다면 전체의 고장율도 낮춰질 수가 있고 이 부분에 같은 종류의 라인을 추가로 설치하면 고장율이 약 1/10로 줄어드는 효과를 보게 된다. 또한 기기단위별로는 6, 7, 26, 27 등이 가장 취약한 것으로 나타났다. 이 부분에 대해서는 안전장치나 설비를 추가로 갖추거나, 혹은 점검기간의 주기를 줄이도록 하는 것이 필요하다. 향후 본 연구에서 다루어진 신뢰도 측정방법을 각 공급설비에 대해 적용한다면 좀 더 효율적으로 공급설비의 신뢰도를 계산, 분석할 수 있고, 천연가스공급설비의 안전성 향상에 도움이 될 것으로 기대된다.