• Title/Summary/Keyword: Fire Hazard

Search Result 553, Processing Time 0.038 seconds

A Study on Hazard of Renewable Energy based Alkaline Water Exectrolysis Equipment (재생에너지 기반 알칼라인 수전해 장치(2 Nm3/hr) 위험요인 고찰)

  • KIM, HYEONKI;SEO, DOOHYOUN;KIM, TAEHUN;RHIE, KWANGWON;LEE, DONGMIN;SHIN, DANBEE
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.1
    • /
    • pp.55-60
    • /
    • 2022
  • As interest in sustainable and eco-friendly energy sources is increasing due to various problems in the carbon society, a hydrogen economy using hydrogen as a main energy source is emerging. While the natural gas reforming method generates carbon dioxide, the water electrolysis method based on renewable energy is eco-friendly. The water electrolysis device currently being developed uses a 2 Nm3/hr class alkaline aqueous solution as an electrolyte and produces hydrogen based on renewable energy. In this study, risk assessment was conducted for these water electrolysis devices

Characteristic of Auto Ignition Temperature due to the Mixture Ratio of Ethylene Glycol and Water (Ethylene Glycol과 물의 혼합비에 따른 자연발화온도 특성)

  • Kim, Jung-Hun;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.24-30
    • /
    • 2016
  • Autoignition characteristic is an important factor of all combustible substances, and a critical determinant in assessing the effectiveness of fire hazard prevention. This study investigated the autoignition characteristic of mixtures of Ethylene Glycol and water using an ASTM D2155 type ignition temperature measuring apparatus. It was possible to get the minimum temperature as $434^{\circ}C$ from 100% Ethylene Glycol within range of $75{\sim}160{\mu}l$. A volume of $100{\sim}125{\mu}l$ of a mixed sample of Ethylene Glycol and water (80 : 20) was ignited at the same temperature ($434^{\circ}C$). Also it was possible to get the auto ignition temperature as $437^{\circ}C$ from a mixed sample of Ethylene Glycol and water (60 : 40) within range of $120{\sim}160{\mu}l$. The instantaneous ignition temperatures determined for $125{\mu}l$ of each of the three samples were $579^{\circ}C$, $595^{\circ}C$ and $611^{\circ}C$, respectively. Both auto ignition temperatures and instantaneous ignition temperatures were increased through the addition of water to the samples.

Hazard Assessment of Combustion Gases from Interior Materials (주요 건축 내장재의 연소가스 유해성 평가)

  • Seo, Hyun Jeong;Son, Dong Won
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.49-56
    • /
    • 2015
  • Toxic gases from five types of interior building materials were investigated according to Naval Engineering Standard (NES) 713. The materials were plywood, indoor wall coverings (wood wall plate members and pine wood), reinforced Styrofoam insulation, laminate flooring, and PVC. Specimens were measured using an NES 713 toxicity test apparatus to analyze the hazardous substances in combustion gas from the materials. We used the US Department of Defense standard (MIL-DTL, Military Standard) to calculate the toxicity index of the combustion gas. Emissions of $CO_2$ from all specimens did not exceed the NES 713 limit of 100,000 ppm. The amount of CO gas emissions from reinforced Styrofoam insulation was 6,098 ppm. 25 ppm and 49 ppm of formaldehyde were released from the reinforced Styrofoam insulation and PVC flooring, respectively. These values were less than the limit of 400 ppm. The highest emissions were from $NO_X$ emitted by plywood and were above the limit of 250 ppm. The toxicity index of the specimens were calculated as 5.19 for plywood, 4.13 for PVC flooring, 2.35 for reinforced Styrofoam insulation, 2.34 for laminate flooring, and 1.22 for indoor wall coverings (pine wood). Our research helps us to understand the properties of these five interior materials by analyzing the combustion gas and explaining the toxicity of constituents and the toxicity index. Also, it would be useful for giving fundamentals to guide the safe use of interior materials for applications.

A Study on Analysis of Characteristics Combustion of Floor Covering Materials (바닥내장재의 연소특성 분석에 관한 연구)

  • Park, Young-Ju;Lee, Hae-Pyeong;Kim, Hyun-Ju
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we analyzed the combustion characteristics of four different floor covering materials(wood, monorium, laminatedpaper, and varnish-laminated paper) with regard to their ignitibility, thermal characteristics and flame retardancy by using an ignition temperature tester, a dual cone calorimeter, a thermogravimetric analyzer and limited oxygen index, for their fire risk assessment. According to the result, monorium had the lowest ignition temperature of $325^{\circ}C$ and the laminated paper and the varnish-laminated paper promptly ignited before 7s. Further, the wood showed the largest total heat release of $100MJ/m^2$, and the varnish-laminated paper showed the highest peak heat release rate. From the thermogravimetric analysis, it was shown that all specimens underwent rapid weight loss at $300{\sim}400^{\circ}C$. The limit oxygen indices of the laminated paper and the varnish-laminated paper were in the range of 20~21%, while it was 34% for wood. This study enabled us to confirm that wood, laminated paper and varnish-laminated paper have a relatively short ignition time and are easy to burn but they all have low heat release. In contrast, wood showed the lowest fire risk among them and had excellent flame retardancy but with high heat release.

Full Scale Testing of the Effect of Stairwell Pressurization on Pressure Differential and Flow Velocity

  • Son, Bong-Sae;Park, Kyung-Hwan;Chang, Young-Bae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.83-89
    • /
    • 2011
  • A series of full-scale testing was conducted to examine the effect of stairwell pressurization on the pressure differential between the stairwell and the auxiliary room and between the auxiliary room and the residence. Also, flow velocity profiles at open doors were measured. The building tested was a condominium that had twenty floors above the ground and two floors underground. For pressurization of the stairs, a blower was used to supply air into the stairwell at one location underground. Thirteen different cases were tested, and test variables included the number of floors with open doors and the flow rate of the air supply. When the doors on the first floor were open, the pressure differential between the stairwell and the auxiliary room was distributed almost uniformly except for locations near the first floor. When the flow rate was in the range of 180~270 CMM and the doors of one floor were open, the flow velocity could satisfy the requirement of fire safety standards and the stairwell pressure was positive at all levels. However, the minimum pressure requirement (10 Pa) could not always be satisfied. When doors on two floors were open, the flow velocity requirement could be satisfied by increasing the flow rate, but it was found impractical to satisfy the minimum pressure requirement without causing excessive pressure differential in the area near the blower.

Effects of Forest Tending Works on the Crown Fuel Characteristics of Pinus densiflora S. et Z. Stands in Korea (숲가꾸기 사업이 소나무림의 수관연료특성에 미치는 영향)

  • Kim, Sungyong;Lee, Byungdoo;Seo, Yeonok;Jang, Mina;Lee, Young Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.3
    • /
    • pp.359-366
    • /
    • 2011
  • The objective of this study was to analyze the changes of crown fire hazard possibility from the effects of forest tending works (FTW) in Pinus densiflora stands in Korea. The study sites were located in Youngju (FTW) and Bonghwa (Control) areas. Ten representative sample trees were destructively felled at each areas to analyze the crown fuel characteristics. The results of this study showed that crown fuel moisture content in Youngju and Bonghwa areas were 103.6% and 104.4%, respectively. The needles and twigs with less than 1cm diameter accounted 50.3% of the total crown fuel load in Youngju area and 62.0% in Bonghwa area. On the other hand, it was observed in Youngju that the canopy bulk density was $0.11kg/m^3$ lower but have 1.3 m higher average canopy base height therefore having a possibility of lower crown fire hazard as compared to Bonghwa that had higher canopy bulk density and lower canopy base height.

A Study on the Ripple Effect Economy of Busan Ubiquitous-Safety Realization on Using an Input-Output Model (I-O모형을 이용한 부산 U-방재 실현의 경제적 파급 효과 분석에 관한 연구)

  • Ryu, Tae-Chang;Kim, Tae-Min;Kim, Gyeong-Su
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.93-100
    • /
    • 2008
  • Dense of population construction and high density of skyscraper, and geological characteristics caused natural disasters(e.g. typhoon, tsunami, flood, storm, earthquake, etc.) and manmade disasters(e.g. fire, collapse, explosion, traffic accident, etc.). the extent and scale of the disaster are getting larger. To cope with such problems, Busan City has established the basic plan to secure the life and property of the citizens through model strategy and design of Ubiquitous-Safety Busan. This study quantitatively analyzed the ripple effect on local economy through the fulfillment of Ubiquitous-Safety. The production inducing effect of 250 billion won directly and indirectly can be estimated due to the realization of Ubiquitous-Safety. The value added effect of 115 billion won can be estimated. the employment effect of 5,580 persons can be generated with income effect of 51 billion won.

A Study on the Improvement Plans of Disaster Response Capabilities for U-city (U-City 재난 대응역량 제고방안에 관한 연구)

  • Park, Hee-Soon;Lee, Jeong-Il;Yoon, Hyung-Goog
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.55-66
    • /
    • 2010
  • As people's living standards and expectations for life increase, by applying advanced technology in the city, to enhance the convenience and safety needs are being expanded gradually. Accordingly, so the future of the city to see a viable alternative to that the ubiquitous city fused information communication technologies, large-scale projects conducted at the national level. Sectoral Disaster Prevention is ready for sure how much the lack of response capabilities in the field for checking solution has been suggested for The National Emergency Management Agency. These results present a Sectoral Disaster Prevention response capabilities somewhat different in were identified. Through these are proposed policy recommendations about Sectoral Disaster Prevention and insufficient areas of step response capabilities and building fire protection system approach combines ubiquitous technology in the new paradigm rather than traditional disaster management, greet era of ubiquitous.

Study on the Escape Safety of University Dormitory with the Consideration of Plan Types (대학 기숙사의 평면 형태에 따른 피난 안전성 검토)

  • Jeong, Hyeon-Jae;Jeong, Gun-Sik;Ahn, Young-Chull
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.6
    • /
    • pp.1-7
    • /
    • 2010
  • University dormitory has some weaknesses against disaster such as fire because of high population density and strict control of access in night time. The purpose of this study is suggestion of a guide of effective floor plan for improvement of evacuation safety. Plans for preventing disasters are studied and evacuation safeties are analysed using network model analysis method according to plan types. The weakness of disaster prevention is quantified, and effectiveness of bidirectional evacuation is confirmed. The circuit type floor plan shows best evacuation characteristics and this result is anticipated to be adopted to design process of new dormitories and will contribute to improvement of evacuation safety.

Initiating Events Study of the First Extraction Cycle Process in a Model Reprocessing Plant

  • Wang, Renze;Zhang, Jiangang;Zhuang, Dajie;Feng, Zongyang
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.117-121
    • /
    • 2016
  • Background: Definition and grouping of initiating events (IEs) are important basics for probabilistic safety assessment (PSA). An IE in a spent fuel reprocessing plant (SFRP) is an event that probably leads to the release of dangerous material to jeopardize workers, public and environment. The main difference between SFRPs and nuclear power plants (NPPs) is that hazard materials spread diffusely in a SFRP and radioactive material is just one kind of hazard material. Materials and Methods: Since the research on IEs for NPPs is in-depth around the world, there are several general methods to identify IEs: reference of lists in existence, review of experience feedback, qualitative analysis method, and deductive analysis method. While failure mode and effect analysis (FMEA) is an important qualitative analysis method, master logic diagram (MLD) method is the deductive analysis method. IE identification in SFRPs should be consulted with the experience of NPPs, however the differences between SFRPs and NPPs should be considered seriously. Results and Discussion: The plutonium uranium reduction extraction (Purex) process is adopted by the technics in a model reprocessing plant. The first extraction cycle (FEC) is the pivotal process in the Purex process. Whether the FEC can function safely and steadily would directly influence the production process of the whole plant-production quality. Important facilities of the FEC are installed in the equipment cells (ECs). In this work, IEs in the FEC process were identified and categorized by FMEA and MLD two methods, based on the fact that ECs are containments in the plant. Conclusion: The results show that only two ECs in the FEC do not need to be concerned particularly with safety problems, and criticality, fire and red oil explosion are IEs which should be emphatically analyzed. The results are accordant with the references.