• Title/Summary/Keyword: Fire Fighting Law

Search Result 44, Processing Time 0.023 seconds

A Study on the Flammability and Combustion Risk of Biodiesel Mixture (바이오디젤 혼합물의 인화 및 연소 위험성에 관한 연구)

  • Kim, Ju Suk;Ko, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.10-24
    • /
    • 2021
  • Purpose: The purpose of this study is to determine the dangers of biodiesel and general diesel mixtures currently used as alternative fuels by equipment (tag method and penski Marten method) and to determine the difference between flash point and combustion point (closed, open) according to test methods. It is intended to be used as a reference material for identification and evaluation of firecausing substances by confirming the risk of mixtures by comparative analysis and measurement, and establishing a risk assessment method for chemical substances. Method: Flash point test method and result treatment were tested based on ASTM and KS M mode, which are tag sealing and pen schematense test methods used as flash point and combustion point test methods for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was a test equipment that satisfies the test standards of KS M 2010 with equipment produced by TANAKA of Japan. The flash point and combustion point were measured, and the flash point according to the test method of biodiesel and general diesel mixture ( Closed, open), and the ignition point of a mixture of biodiesel and general diesel was compared and analyzed for ignition risk compared with conventional diesel. Results: Looking at the experimental results, first, as an analysis of the risk of flammability of the mixture, the flash point of a substance containing 70% biodiesel was found to be about 92℃ based on general diesel with a flash point of 64.5℃, and gasoline and biodiesel or When the biodiesel mixture was synthesized, it was confirmed that the flash point tends to decrease. In addition, the difference between the flash point and the combustion point was analyzed as about 20 ~ 30℃, and when a small amount of gasoline or methanol was mixed, the flash point was lowered, but it was confirmed that the combustion point was similar to that of the existing mixture. Conclusion: In this study, in order to secure the effectiveness of the details of the criteria for judging dangerous materials in the existing Dangerous Materials Safety Management Act, and to secure the reliability and reproducibility of the judgment of dangerous materials, we confirm the criteria for judging the risk of the mixture through an experimental study on flammable mixtures. It will be able to provide reference data for experimental criteria for flammable liquids that are regulated in the field. In addition, if this study accumulates know-how on experiment by test method, it is expected that it can be used as a basis for research on risk assessment and research on dangerous goods.

A Study on Modeling Instruction And Training Program for Korean Private Security Guard (한국 민간경호원 교육프로그램 방향에 관한 연구)

  • Lee, Sang-Chul;Shin, Sang-Min
    • Korean Security Journal
    • /
    • no.9
    • /
    • pp.201-235
    • /
    • 2005
  • This study is designed to contribute for development of Private Security Business by fact-finding in instruction and training of private security guard serviced in this realm and domestic and foreign guard service and modeling effective and rational instruction and training program based on drawn problem. For this study, basically I collected and analyzed documents, theses, and papers of the inside and outside of the country. For practical use of data, I used materials of private security related institutes and police agency. And for private security educating training programs of the inside and outside of the country, I collected materials on internet, and with the help of police agency and interpol. For korean private security company's educating training programs, I made a study with the interview of private security company's businessmen. This study's conclusion is as follows. In a domestic private security enterprise, when set theory instruction minimize instruction and training program and must set up instruction and training program as practical affairs center enemy instruction, and theory instruction must be composed for instruction me that it is connected to practical affairs instruction too. The instruction course of private security guard instruction and training program composed with a security outline, a security plan, an information-gathering, civilian expenses, a security way, terror and terrorism, a related law, security trial, electronic security, a security analysis technique, company introduction, instruction and training program about a professional tube with theory instruction. Practical affairs instruction composed with the selection and a preventive security, close contact attendance security, vehicle security, security driving the security martial arts and self-protection liquor, first aid, security equipment, a gun and shooting, a security protocol, customer satisfaction, facilities security and expenses, a fire fighting instruction, teamwork training, explosive and a dangerous substance, physical strength, a documentation practical affairs, service, instruction and training program about foreigh language instruction.

  • PDF

Development of Project Delivery System in Public Sector for Modular Building (모듈러 건축물의 특성을 반영한 공공발주 방식의 개발)

  • Nam, Sunghoon;Kim, Kyungrai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.4
    • /
    • pp.49-56
    • /
    • 2016
  • Recent research has been ongoing for modular buildings in the country and interest increases. However, the activation of modular building projects is obstructed in the construction industry. There are many reasons to identity for this obstruction but one issue should be focussed. Modular buildings require to change the existing construction production system to a new construction production system, which is factory production - transportation - erection. However, the existing project delivery system in the public sector could not be adapted for this new construction production system due to the obligation of multi prime contract use, such as electrical, communication, fire fighting contracts by Law. Therefore, modular buildings in the existing project delivery system are separately contracted by multi prime contracts and modular units composed of the buildings are contracted by an architectural prime contractor as a commodity. As results, construction costs are increased, potential quality problems are raised and the existing project delivery system is finally an obstacle not to maximize benefits of the modular buildings. In this paper, we propose a new project delivery system for the modular buildings to adapt then ew construction production system.

Performance Ability after CPR Education of the ground workers in an airport (공항 지상 근무자의 심폐소생술 수행능력)

  • Shin, Ji-Hoon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.3
    • /
    • pp.29-40
    • /
    • 2009
  • Objective : This study is an experimental study which is designed to examine the differences between knowledge and self-confidence before and after theory education(CPR PPT material) based on guidelines of CPR and emergency cardiac treatment of American Heart Association(AHA, 2005) and video self-instruction program for the general public by Korean Association of Cardiopulmonary Resuscitation(KACPR), trace CPR performance ability after CPR and AED education and investigate the accuracy of artificial respiration and chest compression, and know the difference in CPR performance abilities including AED. Methods : Subjects of this study include ground crews and staffs at M airport in G province equipped with emergency equipments for CPR according to Art. 47, Sec. 2 of Emergency Medical Law, airport police, rent-a-cops, security guard, quarantine officer, custom officer, and communication, electricity, civil engineering, facility management staff, airport fire fighting staff, air mechanic, traffic controller, and airport management team among airport facility management staffs. They were given explanation of necessity of research and 147 of 220 subjects who gave consent to this research but 73 who were absent from survey were excluded were used as subjects of this study. of 147 subjects, there were 102 men and 45 women. Results : 1) Knowledge score of CPR was $6.18{\pm}0.87$ before instruction and it was increased to $15.12{\pm}1.78$ after instruction, and there was statistically significant difference. 2) Self-confidence score in CPR was $3.16{\pm}0.96$ before instruction and it was increased to $7.05{\pm}0.75$ after instruction, and there was statistically significant difference. 3) Total average score in CPR performance ability after instruction was 7.46 out of 9, performance ability was highest in confirmation of response as 144(97.95%), follwed by request of help as 140(95.25%) and confirmation of respiration as 135(91.83%), and lowest in performing artificial respiration twice(gross elevation of chest) as 97(65.98%). Accuracy of artificial respiration(%) was $28.60{\pm}16.88$ and that of chest compression(%) was $73.10{\pm}22.16$. 4) Performance ability of AED after instruction showed proper performance in power on by 141(95.91%) and attaching pad by 135(91.83%), hand-off for analyzing rhythm showed 'accuracy' in 115(78.23%) and 'non-performance' in 32(21.77%), delivery of shock and hand-off confirmation showed 'accuracy' in 109(74.14%) and 'inaccuracy' in 38(25.86%), and beginning chest compression immediately after AED was done by 105(71.42%).

  • PDF