• 제목/요약/키워드: Fire Fighting Design

검색결과 93건 처리시간 0.043초

국내외 기준 비교를 통한 한국형 성능위주설계 지침서 개발에 관한 연구 (The Study on the Development of PBD Manual according to comparison Each country criteria)

  • 구태윤;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.31-32
    • /
    • 2017
  • The Korea is conducted performance based on design according to fire fighting law in 2009, but it came out problems related to PBD consistently. Especially, there is no specific guideline or code related to evacuation safety verification. so it came out different results according to designer. This study is looking for each country criteria and suggest the basis data for Manual composition through comparison.

  • PDF

도로터널 화재시 대배기구 환기방식에서의 배연 연구 (A Study on the Effective Fire and Smoke Control in Road-Tunnel with Semi-Transverse Ventilation)

  • 전용한;한상철;유지오;김남진;서태범;김종윤
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1244-1250
    • /
    • 2009
  • In this study it is intended to review the moving characteristics of smoke by performing visualization for the calculation of the optimal smoke exhaust air volume in case a fire occurs in tunnels where transverse ventilation is applied, and to obtain basic data necessary for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions under various conditions. As a result of this study, when the critical velocity in the tunnel is 1.75 m/s and 2.5 m/s, the optimal smoke exhaust air volume has to be more than $173\;m^3/s$, $236\;m^3/s$ for the distance of the smoke moving which can limit the distance to 250m. In addition, in case of uniform exhaust the generated smoke is effectively taken away if the two exhaust holes near the fire region are opened at the same time.

  • PDF

펌프 기동 및 정지에 따른 배관 압력상승과 수격작용 영향 고찰 (Consideration of Pressure-Rise and Water Hammer for Pipe System in Relation to Start-Up and Sudden Stop of the Pump)

  • 허민웅;민지호
    • 한국압력기기공학회 논문집
    • /
    • 제13권1호
    • /
    • pp.69-74
    • /
    • 2017
  • In the fire protection system or fire fighting water supply system, the jockey pump is generally installed for the prevention of the pressure decrease of pipes, the frequent driving of the fire pump and protection the pipes from the water hammer. In this paper, the pressure-rise in fire fighting water distribution pipes in condition of pipe pressurization by the surge tank at the start-up and the sudden-stop of the fire pump without additional installation of jockey pump is considered by using simple formula calculations and the evaluation of water hammer occurrence in condition of pipe pressurization by the surge tank is included. As a result, the pressure-rise of pipes is less than the pipe design pressure at the condition of pump's start-up and sudden stop, and the possibility of water hammer occurrence is remarkably low due to pressurization of the pipes by the surge tank.

소방무선대역을 포함하는 인빌딩용 다중대역 중계기 안테나 설계 (Design of Multiband Repeater Antenna with Fire-Fighting Band for In-Building Mobile Communication)

  • 김성민;민경식
    • 한국전자파학회논문지
    • /
    • 제27권6호
    • /
    • pp.495-503
    • /
    • 2016
  • 본 논문은 인빌딩 이동통신용 소방무선대역을 포함하는 다중대역 중계기 안테나의 설계를 제안한 것이다. 제안된 안테나는 원형 평판 위에 중심 모노폴과 4개의 기생소자로 구성되어 있다. 다중대역에서 양호한 반사계수를 실현하기 위해서 4개의 기생소자와 중심 모노폴 사이의 상호 결합을 이용하였다. 기생소자와 중심 모노폴 사이의 거리, 중심 모노폴과 4개의 기생소자 각각의 높이와 같은 중요한 파라미터들이 다중대역에서 양호한 안테나 특성을 얻기 위해 모의실험되어졌다. 기생소자와 중심폴의 지름은 용이한 설계와 제작을 위해서 10 mm로 고정하였다. 측정된 반사계수, 2-D 패턴, 그리고 이득 값은 모의 실험된 값들과 잘 일치하였다.

화재수신기 기반의 화재감시로봇을 위한 프로토콜 설계 (Protocol Design for Fire Receiver­based Fire Detection Robots)

  • 임종천;이재민
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권4호
    • /
    • pp.452-459
    • /
    • 2018
  • 기존의 화재 관련 소방로봇들은 원격조종기로 제어되어 화재현장에서 화재 상황을 감시하거나 화재를 진압하는데 사용되고 있다. 그러나 이러한 방식은 화재 발생 후 골든타임 안에 로봇을 준비하고 투입하는데 많은 시간이 소요되어 소방로봇으로서의 역할을 충분히 다하지 못한다는 문제점을 가지고 있다. 자율 주행 화재감시로봇을 활용하면 화재수신기와 연동하여 화재 신호 발생 시 출동한 로봇이 화재 현장의 동영상을 촬영하여 방재 담당자에게 영상을 전달함으로써 실제로 화재가 발생했는지 또는 오보인지를 확인 할 수 있도록 정확하고 빠른 판단 기회를 제공하고 동시에 화재를 초기 진압함으로써 대형 사고로 확산되는 것을 방지할 수가 있다. 본 논문에서는 자율이동 화재감시로봇의 구성과 이 로봇이 화재수신기와 연동하는데 필요한 통신 프로토콜을 제안한다. 실시간으로 다수의 화재감시로봇을 제어할 수 있는 통신 프로토콜을 설계하며 화재수신기와의 통신을 무선 Wi-Fi를 이용하여 이더넷 네트워크의 인터페이스 역할을 수행하도록 계층적 네트워크로 구성한다. 설계하는 화재감시로봇과 화재수신기간의 무선통신을 구현하고 필드시험을 통하여 동작의 유효성을 확인한다.

자동화재 탐지설비의 비화재보 감소방안 (A Study about False Alarm of Automatic Fire Detection System)

  • 이종화;이춘하;김시국;공하성
    • 대한안전경영과학회지
    • /
    • 제13권1호
    • /
    • pp.41-49
    • /
    • 2011
  • The automatic fire detection system is an important facility installed with focusing on minimizing the damage from a fire. This paper presents in the followings as the methods to reduce the false alarm of the automatic fire detection system; first, to prepare for legal standard so that revised legal standard can be applied to the fire fighting property prior to revision; second, to introduce the performance based fire detection protection design in the law based fire protection design; third, to maintain the wiring of worn-out detector; forth, to introduce an evaluation system to the education for the fire warden; fifth, to extend the standard of MTBF(meantime between failure) of the detector; sixth, to extend of installing the analog type detector; seventh, to improve the structure of reset switch.

119 구급자동차의 내부 디자인 개발에 관한 연구 (Design of Fire-fighting Ambulance Interior)

  • 신동민;박민정;한용택
    • 한국화재소방학회논문지
    • /
    • 제30권1호
    • /
    • pp.121-129
    • /
    • 2016
  • 구급차는 병원 전 응급의료서비스의 중요한 요소이며, 119 구급대원의 업무능률 향상을 위한 중요한 공간이다. 구급대원들이 직무능력을 최대한 발휘할 수 있도록 구급차 내부의 환경을 최적의 공간으로 하여 구급대원들의 책임과 기능적 역할을 제공할 수 있도록 개선되어야 할 것이다. 따라서 본 연구에서는 구급차의 내부 공간에서 환자실에 탑재되어야 하는 응급의료 장비와 약제의 탑재 공간 확보 및 구급차 내에서의 응급처치에 따른 원활한 공간의 배치를 재구성하였으며, 환자의 위치와 응급처치 요원의 배치에 따른 공간 배정에 대한 분석 및 효율적 방법을 제시하고 있다. 또한 본 연구는 구급차 주행 중 처치공간에서 수행하는 119 구급대원 업무의 효율성을 향상시키기 위한 구급대원의 직무수행에 적합한 구급차 내부 수납공간의 디자인 설계 및 사용 환경에 대한 파악 및 문제점 분석을 통하여 응급의료서비스에 대한 안전성과 효율성을 제공하기 위한 새로운 환자실 공간 크기 및 디자인 안을 제시하고자 한다.

소방 활동을 위한 웨어러블 인터페이스 디자인 (Design of Wearable Interface for Fire Fighting)

  • 황재인;김정현;김창헌
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2008년도 학술대회 2부
    • /
    • pp.329-333
    • /
    • 2008
  • 현재 소방관들은 주로 무전기로 다른 소방관이나 중앙 지휘관과 통신을 하고, 필요 정보를 취득 혹은 공유 하면서 소방 활동을 수행 하고 있다. 소방 현장에서는 여러 가지 위험이 존재 하고 이를 극복하기 위해서 많은 정보를 필요로 할 때가 많지만, 이를 미리 모두 숙지 하고 있거나, 동적으로 변화 하는 상황을 무전기를 통하여 취득하고 이해 하기는 쉽지 않다. 이러한 어려운 점을 해소 하기 위하여 웨어러블 컴퓨터를 이용한다면 소방 활동을 도울 수 있을 것이며, 이에 적합한 웨어러블 인터페이스가 디자인 되어야 한다. 이 논문에서는 시나리오에 기반 한 인터액션 모델링, 화재 현장 및 소방 상황에서의 인간공학적 제한 조건, 사용자 설문조사, 그리고 인터페이스 패턴을 기반으로 소방 활동을 효과적으로 도울 수 있는 인터페이스 디자인 및 개발에 대하여 설명하고자 한다.

  • PDF

화재시 열유동장의 수치해석에 대한 평가 연구 (ASSESSMENT ON NUMERICAL ANALYSIS OF THERMAL FLOW INDUCED BY FIRE)

  • 김정엽
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.156-160
    • /
    • 2011
  • As building becomes larger, taller and more complex due to industrialization and urbanization, it tends to be vulnerable to fire and establishment of effective measures for fire safety is demanded. Especially the fact that the smoke hinders evacuation and fire-fighting activities as well as becomes the major cause of life casualty emphasizes the importance of smoke control system. To design and operate the smoke control system success folly, it is necessary to analyze and predict precisely the thermoflow induced by fire in building. The unsteady three-dimensional analysis of thermoflow induced by fire with diverse variables such as building structure, fire conditions and smoke control facilities can be effectively carried out with numerical method In this study, using the FDS(Fire Dynamics Simulation) program that spreads widely as the analysis tool for thermoflow of fire, the analysis of thermoflow in partition of building induced by fire and comparison with the experimental results for assessment of numerical analysis are presented.

  • PDF

지하공동구 화재예방활동 및 진압대책에 관한 연구 (A Study on the Fire Prevention Activities and Suppression Measures of Utility-Pipe Conduit)

  • 이정일
    • 한국방재학회 논문집
    • /
    • 제10권4호
    • /
    • pp.63-68
    • /
    • 2010
  • 지하공동구는 도시 및 공동주택 단지에 반드시 필요한 전력, 통신, 가스, 송유관, 급 배수, 에너지시설 등을 효과적으로 수용하고 도시기반시설의 확장에 따라 파생되는 여러 가지의 문제점을 해결하기 위한 방안으로 시설물을 한곳으로 모아 유지 및 관리하는 시설이다. 지하공동구가 훼손될 경우 국가안보는 물론 사회전반에 미치는 파장이 지대하므로 화재예방 활동 및 진압대 책상 취약점 등을 분석하여 우리 실정에 맞는 방재 대책을 도출하여 공동구의 설계, 제도적인 문제, 방화시설의 문제, 화재확산현상 등을 분석하여 종합적인 화재위험을 분석하여 화재예방활동과 진압대책을 수립하여야 한다. 지하공동구는 밀폐 폐쇄된 공간이므로 산소공급 부족으로 인한 불완전 연소 등으로 농연, 일산화탄소 등 유독성연소생성물의 발생과 열기의 충만 및 시야장해로 진입이 곤란 하는 문제점이 있다. 이러한 현상은 지상화재보다는 지하 화재의 특수성에 비추어 볼 때 화재예방활동은 물론이고 소방전술에서 취약하므로 화재의 효율적인 소방전술이 되기 위해서는 화재의 특이성을 감안하여 유관기관에서는 현장대응 지휘체제를 확립하고, 대응기관에서는 평상시 공동구에 대한 구조파악과 필요한 각종 정보를 수집 기록하고 24시간 관리공조체제 유지 및 대응기관에서 가상종합훈련을 강화하여야하며 근본적으로 공동구내에 설치되어 있는 케이블의 난연화 불연화 및 연소 확대 방지를 위한 대책 등이 필요하다.