A Research of Field Tolerance for Improvement of Fire Fighting Ability in High Rise Structures (고층건축물에서의 소방력 향상을 위한 현장적응성에 관한 연구)

  • Choi, Tae-Young;Park, Nam-Kwun
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.47-55
    • /
    • 2012
  • There are currently various domestic high-rise construction projects underway. Such projects may maximize the economic impact, and yield other benefits, however, there is also a possibility of fire, terrorism, and other disasters that one may not even imagine. This study of high-rise structures' damage reduction measures the fire-fighting ability of the fire fighters at the scene of an indoor emergency upon entry. In order to identify the practical limitations, the fire fighter entered from the 1st floor to reach the top 54th floor. 1.Time required to reach the top floor without the respirator 2.Time required as well as pressure consumption to reach the top floor with the respirator equipped was measured; based on the results, performable range of operations during a fire fighting activity were presented.

A Study on the Method of revitalization for Fire Services' Organization - The Solution for Conflict Between Desk Officials and Outside Duty Ones - (소방공무원의 조직 활성화 방안에 관한 연구 - 내외근 간의 갈등을 중심으로 -)

  • Chae, Jin;Woo, Seong-Cheon
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.85-95
    • /
    • 2009
  • The fire organization of civil servant is a specified public official job which traditionally is characterized by conservative attributes, highly emphasized with a hierarchical culture and the order from higher position. Such a special condition of the fire organization is seemingly regarded as a prerequisite of the occurrence especially prevalent of the systematic discord rather than the other system of a civil servant such as a common administrative job. The conflict among fire officials which is caused by the variety of effort that has been input in pursuit of making a desirable structure does not in progress or even though it dose, weakened by a counterbalance. Therefore, the goal of this research is inducing a plan to revitalize the fire organization through the corroborative analysis of the conflict between indoor duty and outdoor service ones. That is the reason of the disagreement, the device of getting rid of discord and so on.

Study on the Thermal Protective Performance Measurements of Fire Fighter's Protective Clothing for Low Level Radiant Heat Exposures (저열유속 조건의 복사열 노출에 따른 소방보호복의 열보호성능 측정에 관한 연구)

  • Lee, Jun-Kyoung;Bang, Young-Jun;Bang, Chang-Hoon;Kwon, Jung-Suk
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.1-8
    • /
    • 2014
  • Despite advancements in the development of synthetic fibers and materials that provide better insulation, fire burn injuries remain a significant issue. To ensure adequate protection, clothing and equipment must be selected on the basis of performance. There are different standards like ISO standards applicable to each of the various types of clothing used by fire fighters. But, in most cases, the tests are performed in the conditions of high heat flux exposure, the clothing material can be destroyed easily. Thus the effective way to investigate the protective performance for the low (radiant) heat flux conditions should be needed. Therefore improved RPP (Radiant Protective Performance) test method based on the onset of pain burn injury was suggested. Experiments were performed to verify the proposed method with current protective clothing for fire fighters and the transient heat transfer characteristics were identified, also. Moreover, several protective performance indices were acquired from experimental results to analyze their relations.

A Study on Improvement of Disaster Response System in the Firefighting Organization - Focused on Landslide Case in Sinbuk-eup, Chuncheon-city - (소방의 재난대응체계 개선방안에 관한 연구 - 춘천시 신북읍 산사태 대응사례를 중심으로 -)

  • Ko, Gi-Bong;Lee, Si-Young;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.17-31
    • /
    • 2012
  • Regarding the landslide that took place around 00:08 on July 27, 2011, in a village in the city of Chuncheon (Sanjidanggol, Majeoksan, Cheonjeon-ri, Sinbuk-eup, Chuncheon-city, Gangwon-province), this paper surveyed fire-fighting officers who were injected into the site to rescue the disaster, thereby determining the problems surrounding the initial fire-fighting response and improvement measures. As a result, specialist education of volunteer fire-fighters and utilization, improvement measures included the early response ability enhancement of and cooperation between relevant agencies, the strengthening of specialist education about landslide response, the strengthening of situation management and field command system, the installation and operation of speedy field emergency infirmary, the operation of an appropriate volunteer waiting facility, the operation of an appropriate control lines, appropriate control of media, a sufficient securing of individuals' rescue equipment and fuel for heavy equipment, the provision of sufficient portable radios and chargers, the securing of fire-fighting budget thereof.

Sizing System Development of Korean Structural Firefighting Protective Clothing (한국 소방용 방화복의 치수체계 개발)

  • Han, Sul-Ah;Nam, Yun-Ja;Choi, Young-Lim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.5
    • /
    • pp.827-839
    • /
    • 2009
  • Sizing system of Korean structural firefighting protective clothing that is national approved should be met for specification of structural firefighting protective clothing that is identified by Ministry of Public Administration and Security(MOPAS). However if you look over the specification of sizing system, the standard is based on only 'height' and the others are indicated as the size of completed product. KS K ISO 13688 and EN 340 which is met on ISO 13688 which indicates sizing system about protective clothing has the standards of height, chest and waist circumference. Also NFPA 1971 that has standards of sizing system is based on chest circumference, cervical to wrist length, waist circumference and inseam. That is different from Korean standards. Therefore, fire fighting protective clothing standards which is based on only height should be compensated and not be relied on foreign standards like ISO. It is indispensable for developing our own sizing system of structural fire fighting protective clothing. In this studying, Korean new sizing system of structural fire fighting protective clothing was developed for providing basic information of ergonomic structural fire fighting protective clothing. The analyzed target age was between 20 and 59 years old fire fighter who extinguish the fire. And it was analyzed by 3D measurement among data of the $5^{th}$ Size Korea. On conclusion, in case of structural fire fighting protective clothing coat, physical dimension was to be chest circumference, cervical to wrist length. Three dimensions as 5cm space of circumference and four dimensions as 2.5cm space of cervical to wrist length were derived, which means that totally 12 dimensions were defined. Dimension standards of pants was based on the analysis of waist circumference and crotch height. Six dimensions as 5cm space of waist circumference and three dimensions as 5cm space of crotch height were derived, which means that totally 14 dimensions were defined.

Attachment of Two-Way Shape Memory Alloy onto Fabric for Mass Production of Fire Fighters' Turnout Gear (지능형 소방복의 양산화를 위한 이방향 형상기억합금 부착 방법)

  • Park, Mi-Kyung;Lee, Ji-Yeon;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.4
    • /
    • pp.382-390
    • /
    • 2012
  • This study shows the optimum attachment of Two-Way Shape Memory Alloy (TWSMA) springs onto thermal liner and its sewing method for the mass production of fire fighter's intelligent turnout gear. SMA springs were attached to the fabric by four different methods and stitched by two different shapes (square and wave). The durability of the attached springs was tested by laundering up to 50 cycles. Examined were whether the springs would remain attached to the fabric after repeated laundering, the shape memory effect and reaction of the springs, and the anti-corrosiveness of the springs. A Human-Clothing-Environment simulator evaluated thermal insulation according to attachment methods, air layer volume, and stitch types. The findings showed that silicon attached springs remained intact after repeated laundering; in addition, repeated laundering did not influence the responsiveness and anti-corrosiveness of SMAs. Air volume had positive relations with the insulation. Attachment methods or stitch methods had limited impact on the thermal insulation. As a result, a wave type stitch with silicone attachment was suggested as the optimum method to attach the SMA springs onto the intelligent turnout gear for fire fighters.

Protocol Design for Fire Receiver­based Fire Detection Robots (화재수신기 기반의 화재감시로봇을 위한 프로토콜 설계)

  • Lim, Jong-Cheon;Lee, Jae-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.4
    • /
    • pp.452-459
    • /
    • 2018
  • Conventional fire fighting robots are controlled by a remote control to monitor the fire scene or to suppress the fire. However, this method has a problem that it takes a long time to prepare robot and input it to fire place in the golden time after the fire, so that it can not sufficiently serve as a fire fighting robot. Using the autonomous driving fire monitoring robot, when a fire signal is generated, in conjunction with a fire receiver a moving robot takes a video of the fire scene and delivers the image to the fire department, so that the fire fighter can decide if it is real fire or not. Thereby it is possible to prevent a sudden spread of an accident by providing a quick judgment opportunity and at the same time suppressing the fire early. In this paper, we propose an architecture of the autonomous mobile fire monitoring robot and the communication protocol required for the robot to work with the fire receiver. A communication protocol is designed to control multiple fire monitoring robots in real time, and a communication with a fire receiver is designed as a hierarchical network to serve as an interface of an Ethernet network using wireless Wi-Fi. The fire monitoring robot and the wireless communication of the fire receiving period are implemented and the effectiveness of the operation is confirmed through the field test.

The Comparison Analysis of Recognition about Disaster Management Organization of Seoul between Fire Fighters and Regular Officers (서울재난관리조직에 대한 재난관리공무원간의 인식비교분석)

  • Song, Yun-Suk
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.154-164
    • /
    • 2009
  • The administration of Korean local governments in charge of natural disaster management and manmade disaster management has been completely or partially integrated to the fire fighting headquarters since 1990's. Therefore the relationship between the fire fighters and the regular officers has been more important. So in this study, I made a questionnaire about management ability, rescue activities, disaster, business efficiency of the disaster management organization. And then I did a question research to the comparison analysis of recognition between fire fighter and regular officers of Seoul disaster management organization. As a result of the comparative analysis of understanding, there is a meaningful difference among facilities of management ability, man-made disaster of disaster, business cooperation and business connection of business efficiency. Through the comparison analysis of recognition, I tried to present the improvement of Seoul disaster management organization.

A Study on ASET Elongation & Notification Time to Fire Stations for the Escape Safety of Aged Bedridden Patients in Elderly Long-term Medical Care (노인의료복지시설 화재 시 와상노인의 피난안전성 제고를 위한 피난허용시간 연장과 소방기관으로의 통보시간 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.50-59
    • /
    • 2018
  • Recently, huge life losses occurred in the elderly long-term medical care fires due to lack of escape safety. As part of the measures to enhance the effectiveness of fire escape safety, while they prolong the available safe egress time (ASET) of non fire compartments, a measure to shorten fire-fighter's arrival time by fire alarm notifying device should be implemented in these facilities. The four categories from the aspects of fire prevention/protection engineering were provided with the necessary component technologies for carrying out these helper-guided evacuations. Fire prevention engineered technology was presented by two provisions; one for ensuring small compartment sections by installing the fire rated wall between bed rooms and another for ensuring the fire retardant or/and non-flammable performance of finishing materials. Also fire protection engineered technology was presented by two items; one for imposing cooling effects by sprinklers and another for providing automatic fire alarm notifying functions to fire stations. In order to improve the escape safety of these facilities in Korea, alternative revisions may presented by considering insufficient provisions in the architectural/fire law provisions by analyzing the provisions of Japanese and domestic laws in detail.

Discussion on Formulation Process and Configuration of Fire-Fighting Vulnerable Zone Model (소방취약지 모델의 구성과 정립프로세스 논의)

  • Kim, Seong Gon;Chang, Eun Mi;Choi, Gap Yong;Kim, Hi Tae
    • Spatial Information Research
    • /
    • v.22 no.3
    • /
    • pp.71-77
    • /
    • 2014
  • There are numbers of unpredictable risk factors in the disaster scenes such as fire, explosion and fail to early life-saving or holding the flames which can lead to massive damage. In particular, fire-fighters who arrive on the scene within 5 minutes after dispatching, have a limitation to get aware to the situation of scene fully, because of immediate deploy to disaster scene with limited information. This situation may lead to disturbance that fire-fighters perform effective fire-fighting activities, to put fire-fighter's life at risk by misjudge the situation. Previous domestic and International studies focused vulnerability for spatial area or features which can damage to life and property in the event of anticipated. In this study, we have been developed fire-fighting vulnerable zone model that can analyze comprehensively hindrance factors for fire-fighting activities targeting whole life cycle of fire-fighting activities from dispatch to fire suppression or life-saving. In addition, we have been given shape to finality and applicability for our model by defining the new concept of fire-fighting vulnerable zone which can be distinguished from the concept of fire vulnerable area in previous studies. The results of this study can be used to analysis fire-fighting vulnerable zone type analysis, establish fire-fighting policies and improve the performance of decision-making process.