• Title/Summary/Keyword: Fire Factor

Search Result 538, Processing Time 0.027 seconds

A Study on Factors Influencing Fire Service Power - An Analysis of the Fundamental Variable for Fire Service Budget - (소방력에 영향을 미치는 요인에 관한 연구 - 소방예산의 기본변수분석을 중심으로 -)

  • Kim, Jin-Dong
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.9-19
    • /
    • 2008
  • Recently the systematic change in the fire and disaster prevention administration, which was less studied than other administrative systems, has been in progress. In particular, the fire service demands are increasing and forms are diversified. The first thing you must do is to make up the fire service power according to the fire service demands. Such an allocation results in social welfare satisfaction. The purpose of this study is to investigate the determinants of fire service force. And this study investigates that fire service demand is affected by socioeconomic factor. To do this, this study reviews fire service force, the fire service demand, socioeconomic factor and financial factor. And this study sets up four hypotheses based on the theoretical backgrounds and the past research. The statistical method used for the verification of hypotheses are multiple regression analysis and structural equitation analysis. The analysis showed that fire service demand and financial factor were positive significant variable for fire service power. But socioeconomic factor was a negative significant variable. Also the analysis showed that social factor was a positive significant variable and economic factor was a negative significant variable for fire service demand.

Analysis on the Effects of the Heat Loss Coefficient on the Operation Time of Sprinkler in Compartment Fire (구획 화재에서 스프링클러 열 손실계수 변화에 따른 작동 시간 분석)

  • You, Woo Jun
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.34-39
    • /
    • 2018
  • In this study, the experiment conditions for the variation of heat release rate in compartment space were constructed to analyze the effects of fire spread and the operation time of sprinkler in accordance with the heat loss of the sprinkler's heat element. The compartment composed of fire board (width = 0.3 m, height = 0.5 m, length = 3.0 m), are manufactured to measure the temperature distributions in the inner space, the mass loss rate and heat release rate during the experiment of N-heptane pool fire test. Also, the operation time of sprinkler is analyzed with the installation of sprinkler and C-factor using Fire Dynamics Simulator Ver.6 under the experiment conditions. The results show that the operation time of sprinkler, which has RTI $100(m{\cdot}s)^{0.5}$ operating temperature $70^{\circ}C$, is 30 s~60 s for C-factor = 0 and 1, 62 s~92 s for C-factor = 3, and 120 s over for C-factor = 5, respectively.

A Study on the Wildland Fire Total Hazard Classification (산림화재 종합위험등급화에 관한 연구)

  • 김동현;김태구;김광일
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.49-54
    • /
    • 2001
  • Recently, intentional arsons for exploitation and wildland fire caused by abnormal change of weather are increasing as well as the damage scale due to such fire in the world. The number of such big wildland fire is also increasing in Korea these days. Fire prevention activity can be said as more important than fire putting-out activity after a fire occurrence for the most effective way to cope with wildland fire, and the research on wildland fire prevention system is what we need to do urgently, In this study I examined and analyzed the experiments and data about the factors influencing wildland fire and stated the dangerousness of each factor for all of the 6 factors and set up the general dangerousness rating applying each factor's contribution to the dangerousness.

  • PDF

Influence Factors on Job Satisfaction Factor and Spatial Environments Evaluation of Fire-Fighting Officer - Focused on Fire Officials in Incheon Metropolitan City - (소방공무원의 직무만족요소에 의한 공간만족평가 영향에 관한 연구 - 인천지방 소방공무원을 중심으로 -)

  • Han, Myoung-Heum
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.6
    • /
    • pp.61-69
    • /
    • 2016
  • A study on how fire officer's job satisfaction factors influence space satisfaction rates. This article will conduct regression analysis for the study on these three problems. 'What are the factors of fire officer's job satisfaction?', 'Does space satisfaction rates influence job satisfaction rates?', 'Which job satisfaction factor influence space satisfaction rate?' Therefore, variables were set based on the prior study, and before regression analysis was conducted, variables were purified through analysis on primary factor and reliability analysis, and hypothesis test was done via variable calculation. According to the prior study, factors that influence job satisfaction rates are as following; self-regulation of tasks, ethics and responsibility level, relationship with colleagues, job identity. And regression analysis showed that space satisfaction rates do not influence job satisfaction rates. The writer thinks that it's showing that Korean fire officers tend to prioritize colleague relationship and job identity over space improvements. And the factor that influence job satisfaction rates turned out to be the self-regulation of tasks, and the writer estimates that it's reflecting the hierarchical organization culture of current Korean fire officers. Therefore, future Korean fire station design plans need to consider a space plan that provides fire officer's private self-regulation of tasks.

Concept Design of Fire Safety Module for SV20 Service in the Korean e-Navigation System

  • Kim, Byeol;Moon, Serng-Bae;Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.42 no.5
    • /
    • pp.323-330
    • /
    • 2018
  • The Korean e-Navigation system is a Korean approach to correspond with implementation of IMO e-Navigation. It provides five services, among them SV20 service, a ship remote monitoring system that collects and processes sensor information related to fire, navigation, and seakeeping performance safety. The system also detects abnormal conditions such as fires, capsizing, sinking, navigation equipment failure during navigation, and calculates the safety index and determines the emergency level. According to emergency level, it provides appropriate emergency response guidance for the onboard operator. The fire safety module is composed of three sub-modules; each module is the safety index sub-module, the emergency level determination sub-module and emergency response guidance sub-module. In this study, operational concept of the fire safety module in SV20 service is explained, and fire safety assessment factors are estimated, to calculate the fire safety index. Fire assessment factors included 'Fire detector position factor,' 'Smoke diffusion rate factor,' and 'Fire-fighting facilities factor.'

Classification of Fire Damaged Degree Using the Factor Analysis and Cluster Analysis from the Landsat TM Image (Landsat TM 영상에서 요인분석과 군집분석을 이용한 산불 피해정도 분류)

  • Kim, Sung-Hak;Kim, Yeol;Choi, Seung-Pil;Choi, Cheol-Soon
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.211-214
    • /
    • 2007
  • After the forest fire, as access is not easy, forest damage degree are determined with Landsat TM image rather than visual inspection. Therefore in this study, damaged areas are extracted with factor analysis and cluster analysis. Second factor analysis was performed for areas suspicious as forest fire damage areas to evaluate accuracy after separating into strong, medium and light forest fire areas.

  • PDF

A Study on the Regional Resources Facilities Tax (지역자원시설세에 관한 연구 -구 공동시설세를 중심으로-)

  • Kim, Jin-Dong;Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3223-3231
    • /
    • 2013
  • Fire service budget must be increased continually to supply sufficient fire service for safety life of people. A way to increases fire service budget is to plan and improve regional resources facilities tax system. The purpose of this articles is to analyzes the relationship between regional resources facilities tax and fire service budget, fire service investment budget, socioeconomic factor, fire service demand. To do this, this study sets up five hypotheses based on the theoretical backgrounds and the past research. The statistical methods used for the verification of hypotheses are multiple regression analysis and t test. The analysis showed that regional resources facilities tax was positive significant variable for fire service investment budget and fire service budget and socioeconomic factor was a positive significant variable for regional resources facilities tax. And the analysis showed that fire and rescue variable of fire demand factor were positive significant for regional resources facilities tax.

A Study on the Determination of Required Fire Protection Thickness Considering Steel Section Shape (강재단면형상을 고려한 소요 내화피복 두께 산정에 관한 연구)

  • Kim, Hae-Soo;Kang, Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5910-5916
    • /
    • 2011
  • Surface area of the steel member exposed to fire differs according to type and size of the section and the kind of the member, which shows a big difference in the temperature rise of the steel by fire. The section factor ($H_p$/A) is determined by factors such as type, size, and member of the steel and type of the fire protection material, and it is the criteria in determining thickness of the fire protection material. This study showed that the size of the steel increase regardless of the steel type, the section factor decrease. In the results on fire protection thickness of the steel according to the section factor, the efficiency of 1 hour fire protection was lower from 30 to 50% than the criteria. And there is the member, which have the thickness lower the minimum 27% in 2 hour fire protection, but it generally approached in the criteria. In case of H-shape steel, the efficiency of 3 hour fire protection was suitable for the criteria, but rectangular hollow steel section and circular hollow steel section were higher (5.0-17.5%) than the criteria.

A Study on Relations between Shape Factor and Temperature History of Steel of Composit Beam in Standard Fire under Same Thickness Condition of Spray-type Fire Resistant Materials (동일 내화뿜칠 피복조건에서 표준화재에 노출된 합성보의 강재 온도이력 및 단면형상계수와의 관계)

  • Yeo, In-Hwan;Cho, Kyung-Suk;Cho, Bum-Yean
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.72-77
    • /
    • 2012
  • When the concrete and steel combined composite beam is exposed to high temperature, concrete could delay temperature rising of steel by covering or increase heat capacity of structural member. For becoming of structural reinforcing by unification between materials, fire resistance rate of composite beam would be higher than simple steel beam. The temperature rising of exposed steel of composite beam is directly related with section shape and exposure length of steel. In this study, fire resistant tests were carried out for composite beams and steel beam with same thickness of spray-type fire resistant materials in standard fire, and after that, temperature histories were analysed and compared with shape factor. The correlation between steel temperature and shape factor was showed very high. This result suggests that if it can be predict the comparative advantage of member by factor which cause the performance enhancement, it could be conclude that an Standard Accreditation method can be adjust to members without indivisual certifiicate of accreditation.

Optimum Fire Extinguishing Modeling using Impact Factor Analysis on Water Mist System of Pool Fire (영향인자 분석을 통한 고임화재의 미분무수 최적소화 모델링)

  • Hwang, Won-Jun;Kim, Hwang-Jin;Lee, Sung-Eun;Kim, Sung-Won;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.84-89
    • /
    • 2009
  • In this study, the fire extinguishing experiment was performed using a water mist nozzle with variation of factors which affect on the extinguishing time. The variables were distance from nozzle center to fire location, droplet size, height of nozzle and opening or not. With the experimental data, interaction and sensitivity between factors were analysed with Mini tab and deduce a optimum model of fire extinguishing of water mist system. Based on the experiment and modeling of fire extinguishing with water mist system, the most important factor on extinguishing time is the distance from the center of nozzle to fire and the opening effect was small compare with other factors.